語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Design, characterization, and optimi...
~
Eagan, Paige Elizabeth.
FindBook
Google Book
Amazon
博客來
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification./
作者:
Eagan, Paige Elizabeth.
面頁冊數:
189 p.
附註:
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4323.
Contained By:
Dissertation Abstracts International64-09B.
標題:
Chemistry, Analytical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3105602
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification.
Eagan, Paige Elizabeth.
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification.
- 189 p.
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4323.
Thesis (Ph.D.)--University of Florida, 2003.
The research endeavors described in this dissertation focus on the development of a low-end Raman spectroscopic system. The system was designed, characterized, and optimized with respect to instrument function and data analysis. Design criteria stipulated low cost, portability, broad application base, fiber optic sampling, commercially available components, simple data analysis, and ease of use. Primary emphasis was placed on the inexpensive aspect.Subjects--Topical Terms:
586156
Chemistry, Analytical.
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification.
LDR
:03419nmm 2200289 4500
001
1861391
005
20041111121755.5
008
130614s2003 eng d
035
$a
(UnM)AAI3105602
035
$a
AAI3105602
040
$a
UnM
$c
UnM
100
1
$a
Eagan, Paige Elizabeth.
$3
1948992
245
1 0
$a
Design, characterization, and optimization of an inexpensive Raman spectroscopic system for sample identification.
300
$a
189 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4323.
500
$a
Chair: James D. Winefordner.
502
$a
Thesis (Ph.D.)--University of Florida, 2003.
520
$a
The research endeavors described in this dissertation focus on the development of a low-end Raman spectroscopic system. The system was designed, characterized, and optimized with respect to instrument function and data analysis. Design criteria stipulated low cost, portability, broad application base, fiber optic sampling, commercially available components, simple data analysis, and ease of use. Primary emphasis was placed on the inexpensive aspect.
520
$a
The first phase of research concentrated on instrument components. A dispersive, fiber optic Raman spectroscopic system within the aforementioned constraints has been developed. While several Raman instruments are commercially available, they meet a different set of needs. These high-end systems generally provide excellent resolution, low detection limits, and relatively short measurement times. Yet, an increase in design complexity, a decrease in ease of use, and a rise in system costs are additionally associated with these systems. The low-end Raman instrument developed in this research is foreseen as an inexpensive alternative for routine identification purposes. Attention was also placed on a number of signal and noise considerations.
520
$a
After the instrumental phase of the research waned, emphasis was placed on the use of correlation analysis for sample identification. Post-consumer plastics were selected as the samples for this phase of research because they possess relative spectral simplicity while maintaining in-class variations. Additionally, they are readily available and have been successfully evaluated with other independent Raman and correlation studies. A number of spectral factors (e.g., continuum background and fixed pattern noise) were considered and their effects on correlation efficiency were evaluated. In general, a correlation approach presented promising results for sample identification.
520
$a
To improve on the instrument's detection limits, surface-enhanced Raman scattering (SERS) spectroscopy was attempted with the system. A simple and inexpensive method of preparation was used for the production of SERS substrates, which involved the deposition of silver on copper circuit boards via internal electrolysis. The deposition of gold in a similar manner was evaluated as a potential SERS substrate. The results for this portion are mixed; the gold modified surface has not demonstrated consistent signal enhancement, while the silver has yielded positive results. (Abstract shortened by UMI.)
590
$a
School code: 0070.
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0486
710
2 0
$a
University of Florida.
$3
718949
773
0
$t
Dissertation Abstracts International
$g
64-09B.
790
1 0
$a
Winefordner, James D.,
$e
advisor
790
$a
0070
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3105602
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9180091
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入