語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
An electrochemical investigation of ...
~
Seegmiller, Jesse C.
FindBook
Google Book
Amazon
博客來
An electrochemical investigation of corrosion on AA2024-T3.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
An electrochemical investigation of corrosion on AA2024-T3./
作者:
Seegmiller, Jesse C.
面頁冊數:
104 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3440.
Contained By:
Dissertation Abstracts International65-07B.
標題:
Chemistry, Analytical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3139903
ISBN:
0496870440
An electrochemical investigation of corrosion on AA2024-T3.
Seegmiller, Jesse C.
An electrochemical investigation of corrosion on AA2024-T3.
- 104 p.
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3440.
Thesis (Ph.D.)--University of Wyoming, 2004.
An electrochemical corrosion study on the high strength aluminum alloy 2024-T3 has been conducted. This Cu-rich aluminum alloy contains several metallic phases, which are embedded in the Al bulk and provide mechanical strength. These phases afford for the use of 2024-T3 in aerospace applications giving the alloy a high strength to weight ratio. The phases are commonly referred to as inclusions or intermetallic particles (IPs). These IPs have been well documented to function as cathodes and promote corrosion through either Al oxidation or basic attack on the Al bulk matrix from dioxygen reduction products. The scope of this dissertation has been to observe the cathodic capabilities of the IPs by observing the electrochemical phenomena associated with them. This has been done through the use of scanning probe microscopy including scanning electrochemical microscopy (SECM) and diffusion limited electrochemical techniques such as the rotating disk electrode (RDE) and the wall-jet electrochemical flow cell. Scanning electron microscopy (SEM) was routinely used to observe structural damage that the alloy incurred throughout the experiments. Several corrosion inhibitors have also been examined with the above methods. Government regulations are imposing the quest for new corrosion inhibition treatments to replace the existing toxic heavy metal treatments currently used. In this context, new corrosion protection coatings based on inherently conductive polymers (ICPs) along with the "benchmark" Cr(VI) treatments were studied to observe their corrosion inhibition mechanisms.
ISBN: 0496870440Subjects--Topical Terms:
586156
Chemistry, Analytical.
An electrochemical investigation of corrosion on AA2024-T3.
LDR
:02460nmm 2200277 4500
001
1850667
005
20051207082640.5
008
130614s2004 eng d
020
$a
0496870440
035
$a
(UnM)AAI3139903
035
$a
AAI3139903
040
$a
UnM
$c
UnM
100
1
$a
Seegmiller, Jesse C.
$3
1938584
245
1 3
$a
An electrochemical investigation of corrosion on AA2024-T3.
300
$a
104 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3440.
500
$a
Adviser: Daniel A. Buttry.
502
$a
Thesis (Ph.D.)--University of Wyoming, 2004.
520
$a
An electrochemical corrosion study on the high strength aluminum alloy 2024-T3 has been conducted. This Cu-rich aluminum alloy contains several metallic phases, which are embedded in the Al bulk and provide mechanical strength. These phases afford for the use of 2024-T3 in aerospace applications giving the alloy a high strength to weight ratio. The phases are commonly referred to as inclusions or intermetallic particles (IPs). These IPs have been well documented to function as cathodes and promote corrosion through either Al oxidation or basic attack on the Al bulk matrix from dioxygen reduction products. The scope of this dissertation has been to observe the cathodic capabilities of the IPs by observing the electrochemical phenomena associated with them. This has been done through the use of scanning probe microscopy including scanning electrochemical microscopy (SECM) and diffusion limited electrochemical techniques such as the rotating disk electrode (RDE) and the wall-jet electrochemical flow cell. Scanning electron microscopy (SEM) was routinely used to observe structural damage that the alloy incurred throughout the experiments. Several corrosion inhibitors have also been examined with the above methods. Government regulations are imposing the quest for new corrosion inhibition treatments to replace the existing toxic heavy metal treatments currently used. In this context, new corrosion protection coatings based on inherently conductive polymers (ICPs) along with the "benchmark" Cr(VI) treatments were studied to observe their corrosion inhibition mechanisms.
590
$a
School code: 0264.
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0486
690
$a
0548
710
2 0
$a
University of Wyoming.
$3
1017859
773
0
$t
Dissertation Abstracts International
$g
65-07B.
790
1 0
$a
Buttry, Daniel A.,
$e
advisor
790
$a
0264
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3139903
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9200181
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入