Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Bead-based immunoassays with electro...
~
Ronkainen-Matsuno, Niina J.
Linked to FindBook
Google Book
Amazon
博客來
Bead-based immunoassays with electrochemical detection.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Bead-based immunoassays with electrochemical detection./
Author:
Ronkainen-Matsuno, Niina J.
Description:
178 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0721.
Contained By:
Dissertation Abstracts International65-02B.
Subject:
Chemistry, Biochemistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3120889
ISBN:
049668244X
Bead-based immunoassays with electrochemical detection.
Ronkainen-Matsuno, Niina J.
Bead-based immunoassays with electrochemical detection.
- 178 p.
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0721.
Thesis (Ph.D.)--University of Cincinnati, 2003.
Immunoassays with electrochemical detection have gained popularity due to their versatility, low detection limits, relatively easy procedures, and simple instrumentation. Immunoassays have a wide range of applications in clinical chemistry and biodefense as well as agricultural, environmental, and processed food areas. A variety of sensitive amperometric electrochemical detection methods have previously been used with immunoassays. A microelectrode was used here as a detector for bead-based assays in very small sample volumes (down to 10 muL) with low detection limits, fast response times, and fairly good reproducibility. A microelectrode with currents in the pA range and very low charging currents showed great promise as a detector for small volume immunoassays in a biosensor with a microfluidic component. The microelectrode helped overcome the problem of rapid depletion of the electroactive species during detection in small volumes where the macroelectrode would consume the electroactive species faster than the enzymes could produce them. The rapid depletion was seen with macroelectrodes such as the rotating disk electrode.
ISBN: 049668244XSubjects--Topical Terms:
1017722
Chemistry, Biochemistry.
Bead-based immunoassays with electrochemical detection.
LDR
:03155nmm 2200325 4500
001
1847705
005
20051108095748.5
008
130614s2003 eng d
020
$a
049668244X
035
$a
(UnM)AAI3120889
035
$a
AAI3120889
040
$a
UnM
$c
UnM
100
1
$a
Ronkainen-Matsuno, Niina J.
$3
1935739
245
1 0
$a
Bead-based immunoassays with electrochemical detection.
300
$a
178 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0721.
500
$a
Co-Chairs: H. Brian Halsall; William R. Heineman.
502
$a
Thesis (Ph.D.)--University of Cincinnati, 2003.
520
$a
Immunoassays with electrochemical detection have gained popularity due to their versatility, low detection limits, relatively easy procedures, and simple instrumentation. Immunoassays have a wide range of applications in clinical chemistry and biodefense as well as agricultural, environmental, and processed food areas. A variety of sensitive amperometric electrochemical detection methods have previously been used with immunoassays. A microelectrode was used here as a detector for bead-based assays in very small sample volumes (down to 10 muL) with low detection limits, fast response times, and fairly good reproducibility. A microelectrode with currents in the pA range and very low charging currents showed great promise as a detector for small volume immunoassays in a biosensor with a microfluidic component. The microelectrode helped overcome the problem of rapid depletion of the electroactive species during detection in small volumes where the macroelectrode would consume the electroactive species faster than the enzymes could produce them. The rapid depletion was seen with macroelectrodes such as the rotating disk electrode.
520
$a
Ovalbumin protein, a simulant for biotoxins, used as an antigen in immunoassays was characterized using ion exchange chromatography, thermal denaturation, and circular dichroism. Ovalbumin varied in the degree of phosphorylation of the two serine residues between preparations. A microvolume sandwich immunoassay for ovalbumin with enzyme labels was developed on paramagnetic beads that were easy to manipulate, presented short diffusional distances, and hence faster assay times. A rotating disk electrode at a fixed potential was used as a detector.
520
$a
The viability of electrochemical immunoassay as a sensitive technique in a water sample matrix was investigated. Water samples from around the country were characterized with respect to pH and metal content. Sandwich immunoassays for ovalbumin were done in finished water from Cincinnati, OH and from Potomac, MD with minor pretreatment with a chelating agent and a buffering agent.{09}The assay was also done successfully in unfiltered pond water from Cedarville, OH.
590
$a
School code: 0045.
650
4
$a
Chemistry, Biochemistry.
$3
1017722
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Health Sciences, Immunology.
$3
1017716
690
$a
0487
690
$a
0486
690
$a
0982
710
2 0
$a
University of Cincinnati.
$3
960309
773
0
$t
Dissertation Abstracts International
$g
65-02B.
790
1 0
$a
Halsall, H. Brian,
$e
advisor
790
1 0
$a
Heineman, William R.,
$e
advisor
790
$a
0045
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3120889
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9197219
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login