語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Osseointegrated dental implants prod...
~
Kutty, Muralithran G.
FindBook
Google Book
Amazon
博客來
Osseointegrated dental implants produced via microwave processing.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Osseointegrated dental implants produced via microwave processing./
作者:
Kutty, Muralithran G.
面頁冊數:
178 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3093.
Contained By:
Dissertation Abstracts International65-06B.
標題:
Engineering, Materials Science. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3138263
ISBN:
0496854240
Osseointegrated dental implants produced via microwave processing.
Kutty, Muralithran G.
Osseointegrated dental implants produced via microwave processing.
- 178 p.
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3093.
Thesis (Ph.D.)--University of Idaho, 2004.
This research is a comprehensive effort to develop osseointegrated dental implants via microwave processing. A net-shape microwave sintering procedure was employed to fabricate dental implants. Commercial pure titanium powders (-100, -200 and -325 mesh sizes) were used in this work. This process eliminates the need for machining of implants and prevents contamination. The idea was to take advantage of the peculiar way microwave couple with metallic powders, i.e. generating heat in the interior of the sample and dissipating it away through the surface. The desired features for an implant, a dense core with surface pores, is not possible via conventional sintering. Coating with hydroxyapatite via electrodeposition and chemical combustion vapor deposition was also attempted to further enhance the bioactivity of this layer. Surface roughness and area were measured using a non-contact surface profilometer to further describe the unique surface. In-vitro studies, conducted using osteoblast cells extracted from neonatal rat calvarial, showed improved cell growth on all the uncoated porous samples. However, the highest cell growth was observed on the -200 mesh size samples. The higher surface area of the -200 mesh samples is attributed to this observation. This work was able to identify the processing parameters for titanium in microwave and establishes the importance of surface area as a key parameter for cell growth on porous surfaces as compared to surface roughness.
ISBN: 0496854240Subjects--Topical Terms:
1017759
Engineering, Materials Science.
Osseointegrated dental implants produced via microwave processing.
LDR
:02390nmm 2200289 4500
001
1847583
005
20051108095427.5
008
130614s2004 eng d
020
$a
0496854240
035
$a
(UnM)AAI3138263
035
$a
AAI3138263
040
$a
UnM
$c
UnM
100
1
$a
Kutty, Muralithran G.
$3
1935622
245
1 0
$a
Osseointegrated dental implants produced via microwave processing.
300
$a
178 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3093.
500
$a
Major Professor: Sarit B. Bhaduri.
502
$a
Thesis (Ph.D.)--University of Idaho, 2004.
520
$a
This research is a comprehensive effort to develop osseointegrated dental implants via microwave processing. A net-shape microwave sintering procedure was employed to fabricate dental implants. Commercial pure titanium powders (-100, -200 and -325 mesh sizes) were used in this work. This process eliminates the need for machining of implants and prevents contamination. The idea was to take advantage of the peculiar way microwave couple with metallic powders, i.e. generating heat in the interior of the sample and dissipating it away through the surface. The desired features for an implant, a dense core with surface pores, is not possible via conventional sintering. Coating with hydroxyapatite via electrodeposition and chemical combustion vapor deposition was also attempted to further enhance the bioactivity of this layer. Surface roughness and area were measured using a non-contact surface profilometer to further describe the unique surface. In-vitro studies, conducted using osteoblast cells extracted from neonatal rat calvarial, showed improved cell growth on all the uncoated porous samples. However, the highest cell growth was observed on the -200 mesh size samples. The higher surface area of the -200 mesh samples is attributed to this observation. This work was able to identify the processing parameters for titanium in microwave and establishes the importance of surface area as a key parameter for cell growth on porous surfaces as compared to surface roughness.
590
$a
School code: 0089.
650
4
$a
Engineering, Materials Science.
$3
1017759
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Dentistry.
$3
1019378
690
$a
0794
690
$a
0541
690
$a
0567
710
2 0
$a
University of Idaho.
$3
718915
773
0
$t
Dissertation Abstracts International
$g
65-06B.
790
1 0
$a
Bhaduri, Sarit B.,
$e
advisor
790
$a
0089
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3138263
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9197097
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入