語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Comparison of delayed contrast-enhan...
~
Sharma, Puneet.
FindBook
Google Book
Amazon
博客來
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla./
作者:
Sharma, Puneet.
面頁冊數:
286 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1575.
Contained By:
Dissertation Abstracts International66-03B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3170102
ISBN:
0542062976
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla.
Sharma, Puneet.
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla.
- 286 p.
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1575.
Thesis (Ph.D.)--Georgia Institute of Technology, 2005.
Imaging of myocardial viability using the delayed enhancement technique currently provides high image contrast between infarcted and normal tissue with the aid of a magnetization prepared fast gradient echo pulse sequence following the administration of an extracellular contrast agent. However, there exists a degree of image contrast variability and subjectivity due to contrast agent kinetics and user-specified imaging parameters. Also, the technique has not been explored at higher field strengths (3T), which offer greater inherent signal-to-noise ratio. The overall goal of this study is to compare magnetic resonance delayed contrast enhancement of myocardial infarction at 1.5T and 3T.
ISBN: 0542062976Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla.
LDR
:03269nmm 2200313 4500
001
1846235
005
20051117110107.5
008
130614s2005 eng d
020
$a
0542062976
035
$a
(UnM)AAI3170102
035
$a
AAI3170102
040
$a
UnM
$c
UnM
100
1
$a
Sharma, Puneet.
$3
1914779
245
1 0
$a
Comparison of delayed contrast-enhanced magnetic resonance imaging of myocardial viability at 1.5 and 3 tesla.
300
$a
286 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1575.
500
$a
Director: John N. Oshinski.
502
$a
Thesis (Ph.D.)--Georgia Institute of Technology, 2005.
520
$a
Imaging of myocardial viability using the delayed enhancement technique currently provides high image contrast between infarcted and normal tissue with the aid of a magnetization prepared fast gradient echo pulse sequence following the administration of an extracellular contrast agent. However, there exists a degree of image contrast variability and subjectivity due to contrast agent kinetics and user-specified imaging parameters. Also, the technique has not been explored at higher field strengths (3T), which offer greater inherent signal-to-noise ratio. The overall goal of this study is to compare magnetic resonance delayed contrast enhancement of myocardial infarction at 1.5T and 3T.
520
$a
The analysis was conducted by first developing a comprehensive mathematical simulation of the imaging sequence, which allowed modification of various imaging parameters. Simulations were performed to optimize the sequence for flip angle and inversion time, as well as to evaluate the influence of other image parameters that affected contrast. These theoretical results were validated experimentally with phantoms.
520
$a
In vivo post-contrast T1 measurements at 1.5T and 3T from normal volunteers (n = 10) and patients (n = 5) provided more precise input into mathematical optimization simulations. In both populations, longer T1 values were found at 3T compared to 1.5T for normal (pre-contrast: 1.24 +/- .06s vs. 1.07 +/- .05s; post-contrast: 0.34--0.59 vs. 0.33--0.54s, n = 15) and infarcted myocardium (pre-contrast: 1.27 +/- .06s vs. 1.04 +/- .06s; post-contrast: 0.25--0.37s vs. 0.23--0.32s, n = 5). Corresponding simulations using these T1 values revealed an infarct-to-normal tissue contrast gain at 3T of approximately 25%. In vivo image contrast between infarcted and normal tissue following contrast administration was also higher at 3T by approximately 37%.
520
$a
In conclusion, there was good correlation between mathematical simulations of delayed enhancement and experimental results, enabling parameters to be compared and optimized offline given input T1 values. Although contrast-enhanced viability imaging at 3T suffered from artifacts due to field, RF, and inversion pulse inhomogeneity, these results suggest that 3T offers higher contrast-to-noise ratio than 1.5T for this application.
590
$a
School code: 0078.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2 0
$a
Georgia Institute of Technology.
$3
696730
773
0
$t
Dissertation Abstracts International
$g
66-03B.
790
1 0
$a
Oshinski, John N.,
$e
advisor
790
$a
0078
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3170102
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9195749
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入