語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Radiographic validation and reliabil...
~
Hannigan-Downs, Kim.
FindBook
Google Book
Amazon
博客來
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions./
作者:
Hannigan-Downs, Kim.
面頁冊數:
130 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3422.
Contained By:
Dissertation Abstracts International65-07B.
標題:
Health Sciences, Recreation. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3138460
ISBN:
0496856219
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions.
Hannigan-Downs, Kim.
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions.
- 130 p.
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3422.
Thesis (Ph.D.)--Oregon State University, 2004.
The navicular drop test (NDT), Feiss' line (FL) and standing foot angle (SFA) are clinical tests used to estimate the amount of pronation via inferior displacement of the tarsal navicular. Thirty-two patients (female and male, ages 18--65) who sought medical treatment for lower extremity pathologies participated in the study that assessed the reliability and validity of the NDT and the FL. The NDT and FL tests had moderate to good (r = 0.608--0.885) positive correlation values, with the exception of the FL change in position value (r = -.091). The intra-examiner reliability results showed good to excellent consistency for all measures of the NDT and FL tests (ICC = 0.817--0.939). The inter-examiner reliability measures were poor to moderate for the FL test of pronation (ICC = 0.425--0.742), while the reliability for the NDT was moderate to good (ICC = 0.686--0.886). These findings suggest that the validity of the NDT was moderate, and that the FL test was questionable. The intra-examiner reliability was strong for both the NDT and FL tests.
ISBN: 0496856219Subjects--Topical Terms:
1018003
Health Sciences, Recreation.
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions.
LDR
:03167nmm 2200289 4500
001
1843084
005
20051010101556.5
008
130614s2004 eng d
020
$a
0496856219
035
$a
(UnM)AAI3138460
035
$a
AAI3138460
040
$a
UnM
$c
UnM
100
1
$a
Hannigan-Downs, Kim.
$3
1931327
245
1 0
$a
Radiographic validation and reliability of selected measures of pronation and biomechanical analysis of tarsal navicular displacement under static and dynamic loading conditions.
300
$a
130 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3422.
500
$a
Adviser: Rod A. Harter.
502
$a
Thesis (Ph.D.)--Oregon State University, 2004.
520
$a
The navicular drop test (NDT), Feiss' line (FL) and standing foot angle (SFA) are clinical tests used to estimate the amount of pronation via inferior displacement of the tarsal navicular. Thirty-two patients (female and male, ages 18--65) who sought medical treatment for lower extremity pathologies participated in the study that assessed the reliability and validity of the NDT and the FL. The NDT and FL tests had moderate to good (r = 0.608--0.885) positive correlation values, with the exception of the FL change in position value (r = -.091). The intra-examiner reliability results showed good to excellent consistency for all measures of the NDT and FL tests (ICC = 0.817--0.939). The inter-examiner reliability measures were poor to moderate for the FL test of pronation (ICC = 0.425--0.742), while the reliability for the NDT was moderate to good (ICC = 0.686--0.886). These findings suggest that the validity of the NDT was moderate, and that the FL test was questionable. The intra-examiner reliability was strong for both the NDT and FL tests.
520
$a
Forty-six (23 women, 23 men) subjects participated in the study that evaluated the relationship between two static clinical tests (NDT and SFA) of pronation and three-dimensional movement of the bones of the foot. Poor to moderate positive relationships were observed (p < .05) between the NDT and the dynamic navicular movement during the walking and running conditions (Spearman's rho = 0.340 and 0.397, respectively). We observed that each of the regression models used to explain dynamic navicular movement during walking, running, and drop landing were statistically significant (p < 0.05). The explained variance of the dynamic navicular drop for the running condition was the largest (R2 = .531), while the model for walking showed the least explained variance (R2 = .289). The explained variance for dynamic SFA was the greatest for the walking condition (R2 = .373), while the model for drop landing had the least explained variance (R2 = .330). This research supports the continued use of the NDT as an indicator of dynamic navicular displacement, but questions the use of the SFA measurement.
590
$a
School code: 0172.
650
4
$a
Health Sciences, Recreation.
$3
1018003
650
4
$a
Biophysics, General.
$3
1019105
690
$a
0575
690
$a
0786
710
2 0
$a
Oregon State University.
$3
625720
773
0
$t
Dissertation Abstracts International
$g
65-07B.
790
1 0
$a
Harter, Rod A.,
$e
advisor
790
$a
0172
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3138460
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9192598
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入