語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Blood flow measurement from digital ...
~
Jennings, Andrew Harry.
FindBook
Google Book
Amazon
博客來
Blood flow measurement from digital angiography.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Blood flow measurement from digital angiography./
作者:
Jennings, Andrew Harry.
面頁冊數:
64 p.
附註:
Source: Masters Abstracts International, Volume: 45-02, page: 1046.
Contained By:
Masters Abstracts International45-02.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1440037
Blood flow measurement from digital angiography.
Jennings, Andrew Harry.
Blood flow measurement from digital angiography.
- 64 p.
Source: Masters Abstracts International, Volume: 45-02, page: 1046.
Thesis (M.S.)--State University of New York at Buffalo, 2007.
Computational fluid dynamic (CFD) simulations are emerging as a promising tool for diagnosis and treatment planning of vascular diseases such as intracranial aneurysms. In addition to the three-dimensional luminal geometry, prior knowledge of the blood velocity in the feeding artery is required before running a CFD simulation. This thesis describes a new method to extract the blood velocity in arteries using Digital Subtraction Angiography, a procedure routinely used in endovascular intervention. This method, referred to as the "radius-ratio" method, is based on the measurement of the contrast-intensity versus time at two locations along a vessel. The measured time-density curves are fitted to idealized curves that would result if contrast were convected in a fully developed steady pipe flow with an average velocity equal to the average velocity of the pulsatile flow. Centerline blood velocity is calculated by dividing the distance between the two vessel locations by the difference between the projected bolus arrival times at each location. Average velocity is then taken to be half this value. Compared to the existing time-density methods that extract velocity from angiography, the radius-ratio method is potentially more accurate because it incorporates a physics-based flow field model. To test the feasibility of the radius-ratio method in practical settings, the RR method was used to determine the velocity of blood in-vitro for vessel phantoms and in-vivo for canine and rabbit common carotid arteries. The RR computed velocity was then compared with the velocity computed using a standard time-density algorithm, and the velocity measured using an ultrasonic flowprobe. It was found that the accuracy v of both RR and TD methods were similar when compared when a gold standard flowprobe. To obtain a pulsatile canine waveform of velocity from the measured time-averaged velocity, an archetypal waveform in a canine common carotid artery can be scaled by heart rate and average velocity to yielding a approximation to the "true" velocity waveform. In human vasculature, it is postulated that the RR method is appropriate in internal carotid arteries and vertebral arteries.Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Blood flow measurement from digital angiography.
LDR
:03027nmm 2200277 4500
001
1834655
005
20071127115004.5
008
130610s2007 eng d
035
$a
(UMI)AAI1440037
035
$a
AAI1440037
040
$a
UMI
$c
UMI
100
1
$a
Jennings, Andrew Harry.
$3
1923294
245
1 0
$a
Blood flow measurement from digital angiography.
300
$a
64 p.
500
$a
Source: Masters Abstracts International, Volume: 45-02, page: 1046.
500
$a
Adviser: Hui Meng.
502
$a
Thesis (M.S.)--State University of New York at Buffalo, 2007.
520
$a
Computational fluid dynamic (CFD) simulations are emerging as a promising tool for diagnosis and treatment planning of vascular diseases such as intracranial aneurysms. In addition to the three-dimensional luminal geometry, prior knowledge of the blood velocity in the feeding artery is required before running a CFD simulation. This thesis describes a new method to extract the blood velocity in arteries using Digital Subtraction Angiography, a procedure routinely used in endovascular intervention. This method, referred to as the "radius-ratio" method, is based on the measurement of the contrast-intensity versus time at two locations along a vessel. The measured time-density curves are fitted to idealized curves that would result if contrast were convected in a fully developed steady pipe flow with an average velocity equal to the average velocity of the pulsatile flow. Centerline blood velocity is calculated by dividing the distance between the two vessel locations by the difference between the projected bolus arrival times at each location. Average velocity is then taken to be half this value. Compared to the existing time-density methods that extract velocity from angiography, the radius-ratio method is potentially more accurate because it incorporates a physics-based flow field model. To test the feasibility of the radius-ratio method in practical settings, the RR method was used to determine the velocity of blood in-vitro for vessel phantoms and in-vivo for canine and rabbit common carotid arteries. The RR computed velocity was then compared with the velocity computed using a standard time-density algorithm, and the velocity measured using an ultrasonic flowprobe. It was found that the accuracy v of both RR and TD methods were similar when compared when a gold standard flowprobe. To obtain a pulsatile canine waveform of velocity from the measured time-averaged velocity, an archetypal waveform in a canine common carotid artery can be scaled by heart rate and average velocity to yielding a approximation to the "true" velocity waveform. In human vasculature, it is postulated that the RR method is appropriate in internal carotid arteries and vertebral arteries.
590
$a
School code: 0656.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Mechanical.
$3
783786
650
4
$a
Biophysics, Medical.
$3
1017681
690
$a
0541
690
$a
0548
690
$a
0760
710
2 0
$a
State University of New York at Buffalo.
$3
1017814
773
0
$t
Masters Abstracts International
$g
45-02.
790
1 0
$a
Meng, Hui,
$e
advisor
790
$a
0656
791
$a
M.S.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1440037
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9225675
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入