語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Cholesterol oxidase modified microel...
~
Devadoss, Anando.
FindBook
Google Book
Amazon
博客來
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells./
作者:
Devadoss, Anando.
面頁冊數:
150 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-10, Section: B, page: 5367.
Contained By:
Dissertation Abstracts International66-10B.
標題:
Biology, Cell. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3193527
ISBN:
9780542367854
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells.
Devadoss, Anando.
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells.
- 150 p.
Source: Dissertation Abstracts International, Volume: 66-10, Section: B, page: 5367.
Thesis (Ph.D.)--Case Western Reserve University, 2006.
Cholesterol oxidase was immobilized on electrode supported lipid bilayer membranes in an active state. Lipid molecules with a thiol functionality were used to form a sub-monolayer covalently linked to either indium tin oxide (ITO) or platinum electrode surfaces. The outer leaflet of the lipid bilayer membrane was formed using a deoxycholate dialysis method for modification of ITO electrodes. The vesicle fusion method was used to deposit the outer lipid leaflet on platinum electrode surfaces. Ferrocyanide/ferricyanide cyclic voltammetry was used to qualitatively monitor the formation of lipid bilayer at the electrode surfaces. Amperometry was used to detect hydrogen peroxide produced during the enzymatic oxidation of cholesterol at room temperature. Flow injection analysis of solution phase cholesterol at oxidase modified ITO, conventionally sized platinum electrodes, and platinum microelectrodes are reported. Cholesterol oxidase modified platinum electrodes showed Michaelis-Menten kinetic behavior for oxidation of solution phase cholesterol. The characterization studies using solution phase cholesterol at microelectrodes also suggested that the electrode response is limited by enzyme kinetics. Steady state current responses are obtained when the enzyme modified platinum microelectrodes are positioned in contact with the lipid membrane of giant vesicles containing cholesterol as a membrane constituent. The electrode responses correlated with the cholesterol content of the vesicle membrane where higher cholesterol content produces larger responses. Data obtained on contacting Xenopus oocytes demonstrated detection of cholesterol present in the cell plasma membrane. When the membrane cholesterol was decreased by exposure to cyclodextrin solution, decreased amperometric response were observed. For studies at 37 °C, cholesterol oxidase was covalently linked to platinum microelectrodes modified with a sub-monolayer of 11-mercapto undecanoic acid (MUA) using N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) as a cross-linker. Covalently modified oxidase electrodes were used to detect cholesterol in the plasma membrane of oocytes and in the macrophage plasma membrane at 37 °C. Also reported are tapping mode - scanning force microscopy of cholesterol oxidase immobilized in a lipid membrane on mica. Topographic and phase contrast images are consistent with monomers and aggregates of cholesterol oxidase molecules immobilized in the lipid bilayer membrane.
ISBN: 9780542367854Subjects--Topical Terms:
1017686
Biology, Cell.
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells.
LDR
:03519nmm 2200313 4500
001
1831805
005
20070529074723.5
008
130610s2006 eng d
020
$a
9780542367854
035
$a
(UnM)AAI3193527
035
$a
AAI3193527
040
$a
UnM
$c
UnM
100
1
$a
Devadoss, Anando.
$3
1920569
245
1 0
$a
Cholesterol oxidase modified microelectrodes for detection of cholesterol in the plasma membrane of single cells.
300
$a
150 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-10, Section: B, page: 5367.
500
$a
Adviser: James David Burgess.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2006.
520
$a
Cholesterol oxidase was immobilized on electrode supported lipid bilayer membranes in an active state. Lipid molecules with a thiol functionality were used to form a sub-monolayer covalently linked to either indium tin oxide (ITO) or platinum electrode surfaces. The outer leaflet of the lipid bilayer membrane was formed using a deoxycholate dialysis method for modification of ITO electrodes. The vesicle fusion method was used to deposit the outer lipid leaflet on platinum electrode surfaces. Ferrocyanide/ferricyanide cyclic voltammetry was used to qualitatively monitor the formation of lipid bilayer at the electrode surfaces. Amperometry was used to detect hydrogen peroxide produced during the enzymatic oxidation of cholesterol at room temperature. Flow injection analysis of solution phase cholesterol at oxidase modified ITO, conventionally sized platinum electrodes, and platinum microelectrodes are reported. Cholesterol oxidase modified platinum electrodes showed Michaelis-Menten kinetic behavior for oxidation of solution phase cholesterol. The characterization studies using solution phase cholesterol at microelectrodes also suggested that the electrode response is limited by enzyme kinetics. Steady state current responses are obtained when the enzyme modified platinum microelectrodes are positioned in contact with the lipid membrane of giant vesicles containing cholesterol as a membrane constituent. The electrode responses correlated with the cholesterol content of the vesicle membrane where higher cholesterol content produces larger responses. Data obtained on contacting Xenopus oocytes demonstrated detection of cholesterol present in the cell plasma membrane. When the membrane cholesterol was decreased by exposure to cyclodextrin solution, decreased amperometric response were observed. For studies at 37 °C, cholesterol oxidase was covalently linked to platinum microelectrodes modified with a sub-monolayer of 11-mercapto undecanoic acid (MUA) using N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) as a cross-linker. Covalently modified oxidase electrodes were used to detect cholesterol in the plasma membrane of oocytes and in the macrophage plasma membrane at 37 °C. Also reported are tapping mode - scanning force microscopy of cholesterol oxidase immobilized in a lipid membrane on mica. Topographic and phase contrast images are consistent with monomers and aggregates of cholesterol oxidase molecules immobilized in the lipid bilayer membrane.
590
$a
School code: 0042.
650
4
$a
Biology, Cell.
$3
1017686
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Biochemistry.
$3
1017722
650
4
$a
Chemistry, Physical.
$3
560527
650
4
$a
Biophysics, General.
$3
1019105
690
$a
0379
690
$a
0486
690
$a
0487
690
$a
0494
690
$a
0786
710
2 0
$a
Case Western Reserve University.
$3
1017714
773
0
$t
Dissertation Abstracts International
$g
66-10B.
790
1 0
$a
Burgess, James David,
$e
advisor
790
$a
0042
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3193527
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9222668
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入