Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans./
作者:
Nkongchu, Kenneth.
面頁冊數:
172 p.
附註:
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 0925.
Contained By:
Dissertation Abstracts International68-02B.
標題:
Health Sciences, Radiology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR23298
ISBN:
9780494232989
Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans.
Nkongchu, Kenneth.
Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans.
- 172 p.
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 0925.
Thesis (Ph.D.)--Carleton University (Canada), 2007.
Gel dosimeters are suitable for the purpose of 3-D dose verification using imaging methods such as magnetic resonance (MR) imaging, which can provide a spatial resolution of ∼1 mm or better. The two main kinds of gels investigated to date (Fricke and polymer-based gel dosimeters) face various problems which have impeded their full clinical use. The Fricke-based gel dosimeters suffer the problem of spatial information loss with time due to diffusion of radiation-induced ferric ions. Polymer-based gels are quite toxic (carcinogens, teratogens, etc.) and can't be prepared in normoxic conditions. Possible solutions to these problems are the use of fast imaging methods to limit diffusion for Fricke gels and development of less or non toxic gels for the case of polymer gels.
ISBN: 9780494232989Subjects--Topical Terms:
1019076
Health Sciences, Radiology.
Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans.
LDR
:02698nmm 2200277 4500
001
1829392
005
20071107102548.5
008
130610s2007 eng d
020
$a
9780494232989
035
$a
(UMI)AAINR23298
035
$a
AAINR23298
040
$a
UMI
$c
UMI
100
1
$a
Nkongchu, Kenneth.
$3
1918252
245
1 0
$a
Magnetic resonance imaging approaches to gel dosimetry for validation of conformal radiotherapy treatment plans.
300
$a
172 p.
500
$a
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 0925.
502
$a
Thesis (Ph.D.)--Carleton University (Canada), 2007.
520
$a
Gel dosimeters are suitable for the purpose of 3-D dose verification using imaging methods such as magnetic resonance (MR) imaging, which can provide a spatial resolution of ∼1 mm or better. The two main kinds of gels investigated to date (Fricke and polymer-based gel dosimeters) face various problems which have impeded their full clinical use. The Fricke-based gel dosimeters suffer the problem of spatial information loss with time due to diffusion of radiation-induced ferric ions. Polymer-based gels are quite toxic (carcinogens, teratogens, etc.) and can't be prepared in normoxic conditions. Possible solutions to these problems are the use of fast imaging methods to limit diffusion for Fricke gels and development of less or non toxic gels for the case of polymer gels.
520
$a
In this thesis, the ability of the MR imaging Look-Locker method to act as a dose verification tool for Fricke gel dosimeters due to its speed is studied. This is done through the modification of the conventional Look-Locker method to accommodate larger tip angles thereby improving on its precision and accuracy. The optimum method of acquiring the image data in Fourier or k-space so as to limit the effect of image blurring due to a time point spread function inherent of this imaging method is proposed.
520
$a
Also studied is the prospect of using two new polymer-based gel dosimeters with reduced toxicity as a dose verification tool. This is demonstrated by verifying a treatment planned dose distribution using these gel dosimeters and MR imaging. A multiple spin-echo MR imaging sequence is used as the imaging tool, with possible problems which can affect the accuracy of the measured dose distribution such as B1 field inhomogeneity and geometrical distortions due to non-linear gradient magnetic fields mapped out and corrected for.
590
$a
School code: 0040.
650
4
$a
Health Sciences, Radiology.
$3
1019076
650
4
$a
Biophysics, Medical.
$3
1017681
690
$a
0574
690
$a
0760
710
2 0
$a
Carleton University (Canada).
$3
1018407
773
0
$t
Dissertation Abstracts International
$g
68-02B.
790
$a
0040
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR23298
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9220255
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入