語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
A test of CPT and Lorentz symmetry u...
~
Kornack, Thomas Whitmore.
FindBook
Google Book
Amazon
博客來
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer./
作者:
Kornack, Thomas Whitmore.
面頁冊數:
222 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4277.
Contained By:
Dissertation Abstracts International66-08B.
標題:
Physics, Atomic. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3188628
ISBN:
9780542307010
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer.
Kornack, Thomas Whitmore.
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer.
- 222 p.
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4277.
Thesis (Ph.D.)--Princeton University, 2005.
A K-3He co-magnetometer has been developed for a test of Lorentz and CPT symmetry. Polarized K vapor forms a spin-exchange relaxation-free (SERF) magnetometer that has record sensitivity of about 1 fT/ Hz . The polarized 3He effectively suppresses sensitivity to the magnetic fields and gradients. Together, the K-3He co-magnetometer retains sensitivity to anomalous, CPT- and Lorentz-violating fields that couple to electron and nuclear spins differently than a normal magnetic field. Data over the course of 15 months provide upper limits on the coupling energy of a CPT-violating field to neutron spin, b˜n < 1.4 x 10-31 GeV, to proton spin, b˜p < 4.4 x 10-30 GeV, and to electron spin, b˜e < 1.0 x 10-28 GeV. These limits are consistent with the existing limits of b˜n < 1.1 x 10-31 GeV (Bear et al., 2002) and b˜ e < 3.0 x 10-29 GeV (Heckel et al., 2000). The proton sensitivity is better than the published limit of b˜p < 1.8 x 10-27 GeV (Phillips et al., 2001). The long-term sensitivity of the co-magnetometer was significantly limited by sources of systematic noise.
ISBN: 9780542307010Subjects--Topical Terms:
1029235
Physics, Atomic.
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer.
LDR
:02819nmm 2200301 4500
001
1828028
005
20061228142256.5
008
130610s2005 eng d
020
$a
9780542307010
035
$a
(UnM)AAI3188628
035
$a
AAI3188628
040
$a
UnM
$c
UnM
100
1
$a
Kornack, Thomas Whitmore.
$3
1916939
245
1 2
$a
A test of CPT and Lorentz symmetry using a potassium-helium-3 co-magnetometer.
300
$a
222 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4277.
500
$a
Adviser: Michael Valeriovich Romalis.
502
$a
Thesis (Ph.D.)--Princeton University, 2005.
520
$a
A K-3He co-magnetometer has been developed for a test of Lorentz and CPT symmetry. Polarized K vapor forms a spin-exchange relaxation-free (SERF) magnetometer that has record sensitivity of about 1 fT/ Hz . The polarized 3He effectively suppresses sensitivity to the magnetic fields and gradients. Together, the K-3He co-magnetometer retains sensitivity to anomalous, CPT- and Lorentz-violating fields that couple to electron and nuclear spins differently than a normal magnetic field. Data over the course of 15 months provide upper limits on the coupling energy of a CPT-violating field to neutron spin, b˜n < 1.4 x 10-31 GeV, to proton spin, b˜p < 4.4 x 10-30 GeV, and to electron spin, b˜e < 1.0 x 10-28 GeV. These limits are consistent with the existing limits of b˜n < 1.1 x 10-31 GeV (Bear et al., 2002) and b˜ e < 3.0 x 10-29 GeV (Heckel et al., 2000). The proton sensitivity is better than the published limit of b˜p < 1.8 x 10-27 GeV (Phillips et al., 2001). The long-term sensitivity of the co-magnetometer was significantly limited by sources of systematic noise.
520
$a
The co-magnetometer provides a robust platform for precision measurements primarily due to its inherent insensitivity to magnetic field drift and field gradients. Detailed analytic and numerical modeling of the coupled spin ensemble dynamics provides good agreement with steady state and transient response measurements. Elaborate procedures have been developed for running the system optimally and minimizing the magnetic fields and lightshifts in the system.
520
$a
The co-magnetometer also forms a sensitive gyroscope that inherits all the magnetic insensitivity features of the co-magnetometer and adds insensitivity to magnetic fields fast transients. The sensitivity of this gyroscope is competitive with existing compact gyroscope techniques.
590
$a
School code: 0181.
650
4
$a
Physics, Atomic.
$3
1029235
650
4
$a
Physics, Elementary Particles and High Energy.
$3
1019488
690
$a
0748
690
$a
0798
710
2 0
$a
Princeton University.
$3
645579
773
0
$t
Dissertation Abstracts International
$g
66-08B.
790
1 0
$a
Romalis, Michael Valeriovich,
$e
advisor
790
$a
0181
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3188628
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9218891
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入