A quantitative evaluation of dry-sensor electroencephalography.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A quantitative evaluation of dry-sensor electroencephalography./
作者:
Uy, E. Timothy.
面頁冊數:
155 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 1944.
Contained By:
Dissertation Abstracts International66-04B.
標題:
Biophysics, Medical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
ISBN:
9780542084478
A quantitative evaluation of dry-sensor electroencephalography.
Uy, E. Timothy.
A quantitative evaluation of dry-sensor electroencephalography.
- 155 p.
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 1944.
Thesis (Ph.D.)--Stanford University, 2005.
Neurologists, neuroscientists, and experimental psychologists study electrical activity within the brain by recording voltage fluctuations at the scalp. This is electroencephalography (EEG). In conventional or "wet" EEG, scalp abrasion and use of electrolytic paste are required to insure good electrical connection between sensor and skin. Repeated abrasion quickly becomes irritating to subjects, severely limiting the number and frequency of sessions. Several groups have produced "dry" EEG sensors that do not require abrasion or conductive paste. These, in addition to sidestepping the issue of abrasion, promise to reduce setup time from about 30 minutes with a technician to less than 30 seconds without one. The availability of such an instrument would (1) reduce the cost of brain-related medical care, (2) lower the barrier of entry on brain experimentation, and (3) allow individual subjects to contribute substantially more data without fear of abrasion or fatigue.
ISBN: 9780542084478Subjects--Topical Terms:
1017681
Biophysics, Medical.
A quantitative evaluation of dry-sensor electroencephalography.
LDR
:02701nmm 2200289 4500
001
1827857
005
20061228142211.5
008
130610s2005 eng d
020
$a
9780542084478
035
$a
(UnM)AAI3171697
035
$a
AAI3171697
040
$a
UnM
$c
UnM
100
1
$a
Uy, E. Timothy.
$3
1916772
245
1 2
$a
A quantitative evaluation of dry-sensor electroencephalography.
300
$a
155 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 1944.
500
$a
Adviser: Patrick Suppes.
502
$a
Thesis (Ph.D.)--Stanford University, 2005.
520
$a
Neurologists, neuroscientists, and experimental psychologists study electrical activity within the brain by recording voltage fluctuations at the scalp. This is electroencephalography (EEG). In conventional or "wet" EEG, scalp abrasion and use of electrolytic paste are required to insure good electrical connection between sensor and skin. Repeated abrasion quickly becomes irritating to subjects, severely limiting the number and frequency of sessions. Several groups have produced "dry" EEG sensors that do not require abrasion or conductive paste. These, in addition to sidestepping the issue of abrasion, promise to reduce setup time from about 30 minutes with a technician to less than 30 seconds without one. The availability of such an instrument would (1) reduce the cost of brain-related medical care, (2) lower the barrier of entry on brain experimentation, and (3) allow individual subjects to contribute substantially more data without fear of abrasion or fatigue.
520
$a
Accuracy of the EEG is paramount in the medical diagnosis of epilepsy, in experimental psychology and in the burgeoning field of brain-computer interface. Without a sufficiently accurate measurement, the advantages of dry sensors remain a moot point. However, even after nearly a decade, demonstrations of dry EEG accuracy with respect to wet have been limited to visual comparison of short snippets of spontaneous EEG, averaged event-related potentials or plots of power spectrum. In this dissertation, I propose a detailed methodology based on single-trial EEG classification for comparing dry EEG sensors to their wet counterparts. Applied to a set of commercially fabricated dry sensors, this work reveals that dry sensors can perform as well their wet counterparts with careful screening and attention to the bandwidth of interest.
590
$a
School code: 0212.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Physics, Electricity and Magnetism.
$3
1019535
690
$a
0760
690
$a
0607
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
66-04B.
790
1 0
$a
Suppes, Patrick,
$e
advisor
790
$a
0212
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9218720
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入