語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Optimization of drying-end-points me...
~
Rivera Vazquez, Elizabeth.
FindBook
Google Book
Amazon
博客來
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy./
作者:
Rivera Vazquez, Elizabeth.
面頁冊數:
93 p.
附註:
Source: Masters Abstracts International, Volume: 43-01, page: 0220.
Contained By:
Masters Abstracts International43-01.
標題:
Chemistry, Pharmaceutical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1421837
ISBN:
9780496265824
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy.
Rivera Vazquez, Elizabeth.
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy.
- 93 p.
Source: Masters Abstracts International, Volume: 43-01, page: 0220.
Thesis (M.S.)--University of Puerto Rico, Mayaguez (Puerto Rico), 2004.
Automatic control of a fluidized-bed drying process depends on the availability of an in-line sensor to provide accurate measurements of product moisture content. Near-infrared (NIR) spectroscopy technology provides a potentially non-invasive and non-destructive analytical method that could serve as a sensor option for a wide range of applications. The purpose of this research was to investigate the use of NIR spectroscopy for accurate in-line moisture measurements during fluidized-bed drying process and to integrate the NIR set-up as part of drying automation. Five powder mixtures consisting of lactose anhydrous, lactose monohydrate, povidone, blue color additive, and distilled water were dried in a bench-scale fluidized-bed dryer (FBD). Samples were withdrawn from the FBD for the calibration phase. A NIR moisture calibration and validation using partial least squares (PLS) was developed by analyzing statically these samples in conjunction with Karl Fisher Titration. Three probe axial positions were designed and installed in the FBD to take in-line NIR measurements. Due to fluidization effects (segregation and sample density distribution along the bed), a mixed-level factorial experimental design was performed to determine the significance of factors such as mass load, air flow and fiber optic probe axial position in the NIR prediction The response variable to be analyzed was the residual between in-line measurements and static samples taken immediately after. Data analysis indicated that all factors were significant with residuals ranging from 0.04--2.32. A mathematical correlation was determined to predict future residuals as a function of the operating conditions.
ISBN: 9780496265824Subjects--Topical Terms:
550957
Chemistry, Pharmaceutical.
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy.
LDR
:02668nmm 2200289 4500
001
1821047
005
20061110073032.5
008
130610s2004 eng d
020
$a
9780496265824
035
$a
(UnM)AAI1421837
035
$a
AAI1421837
040
$a
UnM
$c
UnM
100
1
$a
Rivera Vazquez, Elizabeth.
$3
1910241
245
1 0
$a
Optimization of drying-end-points measurements for the automation of a fluidized-bed dryer using FT-NIR spectroscopy.
300
$a
93 p.
500
$a
Source: Masters Abstracts International, Volume: 43-01, page: 0220.
500
$a
Adviser: Carlos Velazquez Figueroa.
502
$a
Thesis (M.S.)--University of Puerto Rico, Mayaguez (Puerto Rico), 2004.
520
$a
Automatic control of a fluidized-bed drying process depends on the availability of an in-line sensor to provide accurate measurements of product moisture content. Near-infrared (NIR) spectroscopy technology provides a potentially non-invasive and non-destructive analytical method that could serve as a sensor option for a wide range of applications. The purpose of this research was to investigate the use of NIR spectroscopy for accurate in-line moisture measurements during fluidized-bed drying process and to integrate the NIR set-up as part of drying automation. Five powder mixtures consisting of lactose anhydrous, lactose monohydrate, povidone, blue color additive, and distilled water were dried in a bench-scale fluidized-bed dryer (FBD). Samples were withdrawn from the FBD for the calibration phase. A NIR moisture calibration and validation using partial least squares (PLS) was developed by analyzing statically these samples in conjunction with Karl Fisher Titration. Three probe axial positions were designed and installed in the FBD to take in-line NIR measurements. Due to fluidization effects (segregation and sample density distribution along the bed), a mixed-level factorial experimental design was performed to determine the significance of factors such as mass load, air flow and fiber optic probe axial position in the NIR prediction The response variable to be analyzed was the residual between in-line measurements and static samples taken immediately after. Data analysis indicated that all factors were significant with residuals ranging from 0.04--2.32. A mathematical correlation was determined to predict future residuals as a function of the operating conditions.
590
$a
School code: 0553.
650
4
$a
Chemistry, Pharmaceutical.
$3
550957
650
4
$a
Engineering, Chemical.
$3
1018531
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0491
690
$a
0542
690
$a
0486
710
2 0
$a
University of Puerto Rico, Mayaguez (Puerto Rico).
$3
1017811
773
0
$t
Masters Abstracts International
$g
43-01.
790
1 0
$a
Velazquez Figueroa, Carlos,
$e
advisor
790
$a
0553
791
$a
M.S.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1421837
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9211910
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入