Pacemaker sensing system for atrial capture detection.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Pacemaker sensing system for atrial capture detection./
作者:
Hudson, Lee Edward.
面頁冊數:
143 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6498.
Contained By:
Dissertation Abstracts International65-12B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3157347
ISBN:
0496900730
Pacemaker sensing system for atrial capture detection.
Hudson, Lee Edward.
Pacemaker sensing system for atrial capture detection.
- 143 p.
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6498.
Thesis (Ph.D.)--Texas A&M University, 2003.
Capture detection in the right atrium has been a technical challenge due to the characteristics of the atrial evoked response and post pace artifacts. A system performing capture detection with no active charge balancing pacing pulse, such as a triphasic pulse, has been tested. The system performed capture detection for unipolar pacing and sensing, and the pacing and sensing electrodes were the same. Four dogs were used to study the system with Biotronik Elox 45 BP pacing leads. For each animal the system performed with greater than 99% sensitivity and specificity for capture detection. The results show the feasibility of performing capture detection in the right atrium using the same electrode for pacing and sensing without the use of an active charge balancing pacing pulse.
ISBN: 0496900730Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Pacemaker sensing system for atrial capture detection.
LDR
:01645nmm 2200277 4500
001
1817899
005
20060829133359.5
008
130610s2003 eng d
020
$a
0496900730
035
$a
(UnM)AAI3157347
035
$a
AAI3157347
040
$a
UnM
$c
UnM
100
1
$a
Hudson, Lee Edward.
$3
1907244
245
1 0
$a
Pacemaker sensing system for atrial capture detection.
300
$a
143 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6498.
500
$a
Chair: Charles Lessard.
502
$a
Thesis (Ph.D.)--Texas A&M University, 2003.
520
$a
Capture detection in the right atrium has been a technical challenge due to the characteristics of the atrial evoked response and post pace artifacts. A system performing capture detection with no active charge balancing pacing pulse, such as a triphasic pulse, has been tested. The system performed capture detection for unipolar pacing and sensing, and the pacing and sensing electrodes were the same. Four dogs were used to study the system with Biotronik Elox 45 BP pacing leads. For each animal the system performed with greater than 99% sensitivity and specificity for capture detection. The results show the feasibility of performing capture detection in the right atrium using the same electrode for pacing and sensing without the use of an active charge balancing pacing pulse.
590
$a
School code: 0803.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Medicine and Surgery.
$3
1017756
690
$a
0541
690
$a
0564
710
2 0
$a
Texas A&M University.
$3
718977
773
0
$t
Dissertation Abstracts International
$g
65-12B.
790
1 0
$a
Lessard, Charles,
$e
advisor
790
$a
0803
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3157347
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9208762
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入