Rapid Dixon acquisitions for water/l...
~
Flask, Christopher Alan.
Linked to FindBook
Google Book
Amazon
博客來
Rapid Dixon acquisitions for water/lipid separation in MRI.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Rapid Dixon acquisitions for water/lipid separation in MRI./
Author:
Flask, Christopher Alan.
Description:
140 p.
Notes:
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0391.
Contained By:
Dissertation Abstracts International66-01B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3159456
ISBN:
0496932691
Rapid Dixon acquisitions for water/lipid separation in MRI.
Flask, Christopher Alan.
Rapid Dixon acquisitions for water/lipid separation in MRI.
- 140 p.
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0391.
Thesis (Ph.D.)--Case Western Reserve University, 2005.
The main limitation of current lipid/water suppression techniques in MRI is that these methods significantly increase the overall acquisition time of the particular sequence. For example, the multi-point Dixon methods utilize multiple acquisitions at different echo times to algebraically calculate separate fat and water images. Extended acquisition times result in an undesirable increase in respiratory and cardiac motion artifacts. Rapid acquisitions also reduce the duration of and potential errors in interventional MRI procedures thereby reducing the overall risk to the patient. In this work, rapid acquisition and image reconstruction techniques were developed to improve the temporal resolution of the conventional 2-Point Dixon (2PD) method for lipid/water separation.
ISBN: 0496932691Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Rapid Dixon acquisitions for water/lipid separation in MRI.
LDR
:03329nmm 2200313 4500
001
1816517
005
20060717100350.5
008
130610s2005 eng d
020
$a
0496932691
035
$a
(UnM)AAI3159456
035
$a
AAI3159456
040
$a
UnM
$c
UnM
100
1
$a
Flask, Christopher Alan.
$3
1905895
245
1 0
$a
Rapid Dixon acquisitions for water/lipid separation in MRI.
300
$a
140 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0391.
500
$a
Adviser: Jeffrey L. Duerk.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2005.
520
$a
The main limitation of current lipid/water suppression techniques in MRI is that these methods significantly increase the overall acquisition time of the particular sequence. For example, the multi-point Dixon methods utilize multiple acquisitions at different echo times to algebraically calculate separate fat and water images. Extended acquisition times result in an undesirable increase in respiratory and cardiac motion artifacts. Rapid acquisitions also reduce the duration of and potential errors in interventional MRI procedures thereby reducing the overall risk to the patient. In this work, rapid acquisition and image reconstruction techniques were developed to improve the temporal resolution of the conventional 2-Point Dixon (2PD) method for lipid/water separation.
520
$a
A Keyhole Dixon acquisition was developed by combining a full K-space acquisition with a partial (i.e., keyhole) K-space acquisition. The number of acquired views for the centrally-symmetric keyhole acquisitions was optimized with a perceptual difference model (PDM) to sufficiently oversample the central region of K-space. The Keyhole Dixon technique resulted in a 25--38% reduction in the overall acquisition time relative to the 2PD acquisition for phantom and volunteer imaging studies with perceptual change in image quality.
520
$a
Radial and rectilinear 1-Point Dixon (1PD) acquisitions were developed by applying the Dixon echo time variation between even and odd K-space lines. The oversampling of the central region of K-space inherent in radial acquisitions produced fat and water images from a single acquisition. For the rectilinear 1PD acquisition, a SENSE-like parallel imaging technique was used to separate the on-resonance water signal from the off-resonance lipid signal. Both 1PD acquisitions resulted in a 50% reduction in the 2PD acquisition time with comparable spatial resolution.
520
$a
A genetic algorithm (GA) was used to create time-optimal 2-Point Dixon pulse sequences. The GA produced a Pareto-optimal series of pulse sequences at varying field-of-view (FOV) and readout bandwidth with the combined constraints of both gradient hardware and a vendor-specific peripheral nerve stimulation (PNS) model. The genetic optimization resulted in a 10--15% reduction in acquisition time in comparison to a standard dual-echo pulse sequence and a ∼50% reduction in comparison to a single-echo 2PD acquisition.
590
$a
School code: 0042.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2 0
$a
Case Western Reserve University.
$3
1017714
773
0
$t
Dissertation Abstracts International
$g
66-01B.
790
1 0
$a
Duerk, Jeffrey L.,
$e
advisor
790
$a
0042
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3159456
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9207380
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login