Toward faster and quieter MRI.
~
Kidane, Tesfaye Kebede.
FindBook
Google Book
Amazon
博客來
Toward faster and quieter MRI.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Toward faster and quieter MRI./
作者:
Kidane, Tesfaye Kebede.
面頁冊數:
131 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 2130.
Contained By:
Dissertation Abstracts International66-04B.
標題:
Physics, Electricity and Magnetism. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171259
ISBN:
0542075792
Toward faster and quieter MRI.
Kidane, Tesfaye Kebede.
Toward faster and quieter MRI.
- 131 p.
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 2130.
Thesis (Ph.D.)--Case Western Reserve University, 2005.
This thesis represents a study of partially parallel imaging and active passive shielding with the goal of making MRI faster and quieter. We present the design and optimization of rectangular surface rf coils used for partially parallel imaging. The effect of passive copper shielding applied to the outside of an actively shielded gradient is studied with the aim of substantially reducing induced eddy currents in the cryostat inner bore. A ladder rf coil design with all-neighbors coupling included is considered. First, it is shown that, due to far-neighbor couplings, exact decoupling and degeneracy of normal modes are impossible. A technique for minimizing the frequency spread by appropriate choice of capacitors is investigated. A special surface coil design with an additional "parasitic" loop is considered. This coil is shown to have four exact degenerate normal modes. The theoretical predictions are compared with experimental results. A g-factor calculation of two and four rectangular surface coils is considered. It is shown that g-factors can be minimized by changing the relative orientation of the coils. A new regularization technique for SENSE image reconstruction is considered. This technique requires no prior knowledge of the likelihood of the image. Our numerical simulations applied to simulated data acquired with a four-element phased array coils and reduction factor (R = 4) show that there is a reasonable trade-off between signal and aliasing for a given weighting factor. Two configurations of passive shielding are analyzed. The first uses a cylindrical copper cover applied to the outside gradient assembly circumference, and the second extends the copper over the ends of the gradient assembly. For a z-gradient, a 2mm thick copper layer on the gradient circumference reduces the power deposited in the cryostat inner bore by 26.7dB for 1kHz harmonic gradient excitation. Extending the passive shield to cover the ends of the gradient reduces cryostat inner bore power deposition by more than 22dB for the same frequency. For a transverse gradient a finite element calculation shows that a 2mm copper shield without end caps reduces the eddy currents on the cryostat inner bore by a factor of 30 at the same frequency.
ISBN: 0542075792Subjects--Topical Terms:
1019535
Physics, Electricity and Magnetism.
Toward faster and quieter MRI.
LDR
:03125nmm 2200289 4500
001
1816000
005
20060717150835.5
008
130610s2005 eng d
020
$a
0542075792
035
$a
(UnM)AAI3171259
035
$a
AAI3171259
040
$a
UnM
$c
UnM
100
1
$a
Kidane, Tesfaye Kebede.
$3
1905399
245
1 0
$a
Toward faster and quieter MRI.
300
$a
131 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 2130.
500
$a
Adviser: Robert W. Brown.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2005.
520
$a
This thesis represents a study of partially parallel imaging and active passive shielding with the goal of making MRI faster and quieter. We present the design and optimization of rectangular surface rf coils used for partially parallel imaging. The effect of passive copper shielding applied to the outside of an actively shielded gradient is studied with the aim of substantially reducing induced eddy currents in the cryostat inner bore. A ladder rf coil design with all-neighbors coupling included is considered. First, it is shown that, due to far-neighbor couplings, exact decoupling and degeneracy of normal modes are impossible. A technique for minimizing the frequency spread by appropriate choice of capacitors is investigated. A special surface coil design with an additional "parasitic" loop is considered. This coil is shown to have four exact degenerate normal modes. The theoretical predictions are compared with experimental results. A g-factor calculation of two and four rectangular surface coils is considered. It is shown that g-factors can be minimized by changing the relative orientation of the coils. A new regularization technique for SENSE image reconstruction is considered. This technique requires no prior knowledge of the likelihood of the image. Our numerical simulations applied to simulated data acquired with a four-element phased array coils and reduction factor (R = 4) show that there is a reasonable trade-off between signal and aliasing for a given weighting factor. Two configurations of passive shielding are analyzed. The first uses a cylindrical copper cover applied to the outside gradient assembly circumference, and the second extends the copper over the ends of the gradient assembly. For a z-gradient, a 2mm thick copper layer on the gradient circumference reduces the power deposited in the cryostat inner bore by 26.7dB for 1kHz harmonic gradient excitation. Extending the passive shield to cover the ends of the gradient reduces cryostat inner bore power deposition by more than 22dB for the same frequency. For a transverse gradient a finite element calculation shows that a 2mm copper shield without end caps reduces the eddy currents on the cryostat inner bore by a factor of 30 at the same frequency.
590
$a
School code: 0042.
650
4
$a
Physics, Electricity and Magnetism.
$3
1019535
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0607
690
$a
0541
690
$a
0574
710
2 0
$a
Case Western Reserve University.
$3
1017714
773
0
$t
Dissertation Abstracts International
$g
66-04B.
790
1 0
$a
Brown, Robert W.,
$e
advisor
790
$a
0042
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171259
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9206863
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入