語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development of a trans-rotational te...
~
Leiweke, Robert John.
FindBook
Google Book
Amazon
博客來
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence./
作者:
Leiweke, Robert John.
面頁冊數:
283 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-03, Section: B, page: 1365.
Contained By:
Dissertation Abstracts International65-03B.
標題:
Physics, Astronomy and Astrophysics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3124997
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence.
Leiweke, Robert John.
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence.
- 283 p.
Source: Dissertation Abstracts International, Volume: 65-03, Section: B, page: 1365.
Thesis (Ph.D.)--The Ohio State University, 2004.
A new trans-rotational temperature diagnostic with +/-50K accuracy has been developed for use in nonequilibrium, low temperature, monatomic gases seeded with carbon monoxide (CO). The scheme utilizes single-photon laser induced fluorescence (LIF) of CO under vibrationally-excited conditions in which single-photon transitions from the CO X1Sigma + ground electronic state to upper electronic A1pi or D'1Sigma+ states become accessible to a tunable, narrowband ArF excimer laser at 193 nm. Two vibrationally excited environments in which the chemistry is well understood were used as a testbed; an optically-pumped 3% CO/Ar plasma at 100 torr and a 4% CO/He d.c. glow discharge at 8 torr. The LIF saturation limit was experimentally investigated and diagnostic advantages of either regime discussed. For the optically-pumped CO/Ar plasma, a spatially-averaged LIF temperature of 536 +/- 103 K (2sigma) was obtained from rotationally resolved X 1Sigma+ (v″ = 20) → D '1Sigma+ (v' = 2) LIF excitation spectra. Temperature measurements pumping the X 1Sigma+ (v″ = 7) → A 1pi (v' = 1) 4th Positive (528 +/- 51 K) were also found to compare well with line-of-sight Fourier Transform-InfraRed (FT-IR) emission measurements (536 +/- 10 K). Spatially averaged FT-IR spectroscopy of the CO 1st overtone was used to verify that an adequate vibrational population (∼0.1%) existed within the positive column of the CO/He d.c. glow discharge. The A-X (7,1) transition was pumped and subsequent (8,1) emission at 200.8 nm collected. The resulting rotational spectral peaks were assigned and a subset used to determine a spatially averaged rotational temperature of 432 +/- 44 K on the discharge centerline. This was found to be in good agreement with FT-IR spectroscopy measurements (395 +/- 10 K).Subjects--Topical Terms:
1019521
Physics, Astronomy and Astrophysics.
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence.
LDR
:03809nmm 2200313 4500
001
1810953
005
20041216102951.5
008
130614s2004 eng d
035
$a
(UnM)AAI3124997
035
$a
AAI3124997
040
$a
UnM
$c
UnM
100
1
$a
Leiweke, Robert John.
$3
1900543
245
1 0
$a
Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single-photon laser-induced fluorescence.
300
$a
283 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-03, Section: B, page: 1365.
500
$a
Adviser: Walter R. Lempert.
502
$a
Thesis (Ph.D.)--The Ohio State University, 2004.
520
$a
A new trans-rotational temperature diagnostic with +/-50K accuracy has been developed for use in nonequilibrium, low temperature, monatomic gases seeded with carbon monoxide (CO). The scheme utilizes single-photon laser induced fluorescence (LIF) of CO under vibrationally-excited conditions in which single-photon transitions from the CO X1Sigma + ground electronic state to upper electronic A1pi or D'1Sigma+ states become accessible to a tunable, narrowband ArF excimer laser at 193 nm. Two vibrationally excited environments in which the chemistry is well understood were used as a testbed; an optically-pumped 3% CO/Ar plasma at 100 torr and a 4% CO/He d.c. glow discharge at 8 torr. The LIF saturation limit was experimentally investigated and diagnostic advantages of either regime discussed. For the optically-pumped CO/Ar plasma, a spatially-averaged LIF temperature of 536 +/- 103 K (2sigma) was obtained from rotationally resolved X 1Sigma+ (v″ = 20) → D '1Sigma+ (v' = 2) LIF excitation spectra. Temperature measurements pumping the X 1Sigma+ (v″ = 7) → A 1pi (v' = 1) 4th Positive (528 +/- 51 K) were also found to compare well with line-of-sight Fourier Transform-InfraRed (FT-IR) emission measurements (536 +/- 10 K). Spatially averaged FT-IR spectroscopy of the CO 1st overtone was used to verify that an adequate vibrational population (∼0.1%) existed within the positive column of the CO/He d.c. glow discharge. The A-X (7,1) transition was pumped and subsequent (8,1) emission at 200.8 nm collected. The resulting rotational spectral peaks were assigned and a subset used to determine a spatially averaged rotational temperature of 432 +/- 44 K on the discharge centerline. This was found to be in good agreement with FT-IR spectroscopy measurements (395 +/- 10 K).
520
$a
As a prelude to Planar-LIF (PLIF) temperature measurements, vibrationally-resolved emission from laser excitation of various rotational lines within the A-X and D'-X bands were used to investigate spectral interferences. This information was used to determine that a simple aqueous organic filter (urea) in the A-X case, or commercial glass filter (UG-11) in the D '-X case, are adequate for rejecting elastically-scattered radiation and extraneous ro-vibrational bands during PLIF imaging.
520
$a
Single-shot and accumulated PLIF images were obtained for the 3% CO/Ar optically pumped plasma. Using a Two-Line ratio method, A-X band Q-branch images were used to spatially resolve the trans-rotational temperature. While the single-shot precision, determined from four trials, was ≈+/-200 K (2sigma), the accuracy was ≈+/-100 K. The accuracy of PLIF results implied a systematic error which may be attributed to the ICCD camera having a slightly nonlinear response at the 50% gain setting.
590
$a
School code: 0168.
650
4
$a
Physics, Astronomy and Astrophysics.
$3
1019521
650
4
$a
Physics, Fluid and Plasma.
$3
1018402
650
4
$a
Engineering, Aerospace.
$3
1018395
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0606
690
$a
0759
690
$a
0538
690
$a
0548
710
2 0
$a
The Ohio State University.
$3
718944
773
0
$t
Dissertation Abstracts International
$g
65-03B.
790
1 0
$a
Lempert, Walter R.,
$e
advisor
790
$a
0168
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3124997
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
2 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9182587
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
W9185612
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
2 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入