Quality assurance and treatment verification for intensity-modulated radiation therapy.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Quality assurance and treatment verification for intensity-modulated radiation therapy./
作者:
Richardson, Susan Lynn.
面頁冊數:
143 p.
附註:
Source: Dissertation Abstracts International, Volume: 64-05, Section: B, page: 2254.
Contained By:
Dissertation Abstracts International64-05B.
標題:
Physics, Radiation. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3089699
Quality assurance and treatment verification for intensity-modulated radiation therapy.
Richardson, Susan Lynn.
Quality assurance and treatment verification for intensity-modulated radiation therapy.
- 143 p.
Source: Dissertation Abstracts International, Volume: 64-05, Section: B, page: 2254.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2003.
Inverse planning utilized in Intensity Modulation Radiation Therapy (IMRT) results in steep dose gradients near edges of tumors and critical structures. It is imperative for both tumor control and quality of life that the prescribed treatment dose is delivered accurately. Dose verification for IMRT is more complicated than conventional treatment verification due to many irregular field sizes and multiple portals per gantry angle. It also involves continuously changing fields called sliding windows. New types of quality assurance processes are required for these patient treatments. In this work, a film/phantom system is used to verify treatment delivery.Subjects--Topical Terms:
1019212
Physics, Radiation.
Quality assurance and treatment verification for intensity-modulated radiation therapy.
LDR
:03410nmm 2200325 4500
001
1810767
005
20040329092837.5
008
130610s2003 eng d
035
$a
(UnM)AAI3089699
035
$a
AAI3089699
040
$a
UnM
$c
UnM
100
1
$a
Richardson, Susan Lynn.
$3
1900364
245
1 0
$a
Quality assurance and treatment verification for intensity-modulated radiation therapy.
300
$a
143 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-05, Section: B, page: 2254.
500
$a
Supervisors: Bhudatt R. Paliwal; W. A. Tome.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2003.
520
$a
Inverse planning utilized in Intensity Modulation Radiation Therapy (IMRT) results in steep dose gradients near edges of tumors and critical structures. It is imperative for both tumor control and quality of life that the prescribed treatment dose is delivered accurately. Dose verification for IMRT is more complicated than conventional treatment verification due to many irregular field sizes and multiple portals per gantry angle. It also involves continuously changing fields called sliding windows. New types of quality assurance processes are required for these patient treatments. In this work, a film/phantom system is used to verify treatment delivery.
520
$a
There are three major steps in a patient treatment quality assurance process: verification of the patient positioning, validation of the treatment planning software, and confirmation of the delivered dose with measurements. At our institution, the first step is performed using an optical guidance system that yields reproducible positioning to 0.1 mm and 0.1°. The latter two are carried out by using a phantom with film placed in a spiral groove inside the phantom. Together, the system allows accurate prediction, three-dimensional sampling, and measurement of the intended intensity modulated dose distribution. In conjunction with a semi-absolute dose measurement, it also verifies the treatment planning system dose calculation.
520
$a
Case studies involving the spiral film phantom and a semi-absolute dosimetry measurement using TLDs are included in this thesis. Film analyses have been conducted using isodose distributions and dose area histograms provided by RIT film scanning software and pass/fail maps using PTW's VeriSoft. A new formalism for evaluation of dose distributions is given, and a statistical analysis will be presented of the spiral film system.
520
$a
The system described has been utilized to verify intensity modulated fields produced on a linac. It can also be used in static collimator or sliding window techniques of intensity-modulated delivery as well as on tomotherapy machines. Though used here exclusively for intensity-modulated beams, it can be employed to verify conventional treatments. Additionally, it does not require the use of optical guidance, though the best localization procedure should be used. The phantom is robust and versatile, resulting in quick and accurate treatment plan verification.
590
$a
School code: 0262.
650
4
$a
Physics, Radiation.
$3
1019212
650
4
$a
Health Sciences, Radiology.
$3
1019076
650
4
$a
Biophysics, Medical.
$3
1017681
690
$a
0756
690
$a
0574
690
$a
0760
710
2 0
$a
The University of Wisconsin - Madison.
$3
626640
773
0
$t
Dissertation Abstracts International
$g
64-05B.
790
1 0
$a
Paliwal, Bhudatt R.,
$e
advisor
790
1 0
$a
Tome, W. A.,
$e
advisor
790
$a
0262
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3089699
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9171494
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入