Effects of seven days of continuous ...
~
Ment, Stephanie.
Linked to FindBook
Google Book
Amazon
博客來
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia./
Author:
Ment, Stephanie.
Description:
95 p.
Notes:
Source: Masters Abstracts International, Volume: 40-04, page: 0970.
Contained By:
Masters Abstracts International40-04.
Subject:
Health Sciences, Dentistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MQ64407
ISBN:
9780612644076
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia.
Ment, Stephanie.
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia.
- 95 p.
Source: Masters Abstracts International, Volume: 40-04, page: 0970.
Thesis (M.Sc.)--McGill University (Canada), 2000.
The effect of 7 days of continuous capacitive electrical stimulation on bone growth around titanium implants placed in the tibiae of adult male rats, was evaluated in this study. The animals were 'hooked-up' to an external power supply, emitting a symmetrical sinusoidal wave form with an amplitude of 2.0 volt p-p and a frequency of 60 kHz. The current values tested were 20muA, 30muA and 60muA. In surgery I, a head cap was affixed to the animal's skull with stainless-steel screws and an acrylic resin. The head cap was connected to the external power supply by an electrical stimulation wire, encased in a stainless-steel spring. Two electrical leads were subcutaneously tunneled from the head cap to the future tibial implant site, and sutured to the soft tissues. After a one week acclimatization period, a second surgical procedure, surgery II, involved the placement of titanium implants proximal to the tibial tuberosity in each tibiae. Electrodes were then sutured one on either side of the implant, thus 'cuffing' the implant, and the current was then applied to one implant site with the other acting as a control.
ISBN: 9780612644076Subjects--Topical Terms:
1019378
Health Sciences, Dentistry.
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia.
LDR
:02260nam 2200289 4500
001
1393834
005
20110406091702.5
008
130515s2000 ||||||||||||||||| ||eng d
020
$a
9780612644076
035
$a
(UMI)AAIMQ64407
035
$a
AAIMQ64407
040
$a
UMI
$c
UMI
100
1
$a
Ment, Stephanie.
$3
1672411
245
1 0
$a
Effects of seven days of continuous capacitive electrical stimulation on bone growth around titanium implants in the rat tibia.
300
$a
95 p.
500
$a
Source: Masters Abstracts International, Volume: 40-04, page: 0970.
500
$a
Adviser: G. F. McCarthy.
502
$a
Thesis (M.Sc.)--McGill University (Canada), 2000.
520
$a
The effect of 7 days of continuous capacitive electrical stimulation on bone growth around titanium implants placed in the tibiae of adult male rats, was evaluated in this study. The animals were 'hooked-up' to an external power supply, emitting a symmetrical sinusoidal wave form with an amplitude of 2.0 volt p-p and a frequency of 60 kHz. The current values tested were 20muA, 30muA and 60muA. In surgery I, a head cap was affixed to the animal's skull with stainless-steel screws and an acrylic resin. The head cap was connected to the external power supply by an electrical stimulation wire, encased in a stainless-steel spring. Two electrical leads were subcutaneously tunneled from the head cap to the future tibial implant site, and sutured to the soft tissues. After a one week acclimatization period, a second surgical procedure, surgery II, involved the placement of titanium implants proximal to the tibial tuberosity in each tibiae. Electrodes were then sutured one on either side of the implant, thus 'cuffing' the implant, and the current was then applied to one implant site with the other acting as a control.
520
$a
After seven days of continuous capacitive electrical stimulation, a biomechanical pull-out test was carried out to measure the force in Newtons (N) of implant extraction. (Abstract shortened by UMI.)
590
$a
School code: 0781.
650
4
$a
Health Sciences, Dentistry.
$3
1019378
650
4
$a
Biophysics, Medical.
$3
1017681
690
$a
0567
690
$a
0760
710
2
$a
McGill University (Canada).
$3
1018122
773
0
$t
Masters Abstracts International
$g
40-04.
790
1 0
$a
McCarthy, G. F.,
$e
advisor
790
$a
0781
791
$a
M.Sc.
792
$a
2000
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=MQ64407
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9156973
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login