An investigation of dental implant biomechanical behavior using a robot simulation system.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
An investigation of dental implant biomechanical behavior using a robot simulation system./
作者:
Wang, Liqun.
面頁冊數:
206 p.
附註:
Source: Dissertation Abstracts International, Volume: 58-02, Section: B, page: 0941.
Contained By:
Dissertation Abstracts International58-02B.
標題:
Engineering, Mechanical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9722153
ISBN:
9780591306422
An investigation of dental implant biomechanical behavior using a robot simulation system.
Wang, Liqun.
An investigation of dental implant biomechanical behavior using a robot simulation system.
- 206 p.
Source: Dissertation Abstracts International, Volume: 58-02, Section: B, page: 0941.
Thesis (Ph.D.)--University of Kentucky, 1997.
In order to develop in vitro testing to measure the force transmission between dental implants and attached prostheses, this dissertation proposes a new approach involving a robot simulation system. The system has been designed to produce simulated mandibular movements and occlusal contact forces so that various implant designs and procedures can be thoroughly tested and evaluated prior to animal testing or human clinical trial. A set of noncontact displacement probes are used to measure lower jaw/implant deformations during simulated chewing. A multi-axis force/torque sensor is mounted on the end effector for measurement and feedback of overall force levels, and a system of strain gages is used to ascertain force levels transmitted by individual teeth. Quantitative and qualitative analyses of the resultant data have been performed to understand the mechanism of the force transformation between the force load and the implant-tooth combination during various chewing cycles. A theoretical model also has been established. It is found that torque in retaining screws, friction coefficient of implant material, and its geometry can have significant effects on the stability of a dental implant system. Two types of dental bridge connections, with a rigid connector and a nonrigid connector, has been constructed and used for experimental verification. A significant displacement difference in premolars are observed. This information will be useful in understanding the manner in which potentially harmful levels of force are transmitted to human bone surrounding dental implants and adjacent teeth, by providing more accurate force input data for finite element models which are under development. This investigation would provide the unique opportunity to combine robotics with dentistry to improve the oral health of patients.
ISBN: 9780591306422Subjects--Topical Terms:
783786
Engineering, Mechanical.
An investigation of dental implant biomechanical behavior using a robot simulation system.
LDR
:02743nam 2200277 4500
001
1393815
005
20110406091657.5
008
130515s1997 ||||||||||||||||| ||eng d
020
$a
9780591306422
035
$a
(UMI)AAI9722153
035
$a
AAI9722153
040
$a
UMI
$c
UMI
100
1
$a
Wang, Liqun.
$3
1672393
245
1 3
$a
An investigation of dental implant biomechanical behavior using a robot simulation system.
300
$a
206 p.
500
$a
Source: Dissertation Abstracts International, Volume: 58-02, Section: B, page: 0941.
500
$a
Director: J. Peter Sadler.
502
$a
Thesis (Ph.D.)--University of Kentucky, 1997.
520
$a
In order to develop in vitro testing to measure the force transmission between dental implants and attached prostheses, this dissertation proposes a new approach involving a robot simulation system. The system has been designed to produce simulated mandibular movements and occlusal contact forces so that various implant designs and procedures can be thoroughly tested and evaluated prior to animal testing or human clinical trial. A set of noncontact displacement probes are used to measure lower jaw/implant deformations during simulated chewing. A multi-axis force/torque sensor is mounted on the end effector for measurement and feedback of overall force levels, and a system of strain gages is used to ascertain force levels transmitted by individual teeth. Quantitative and qualitative analyses of the resultant data have been performed to understand the mechanism of the force transformation between the force load and the implant-tooth combination during various chewing cycles. A theoretical model also has been established. It is found that torque in retaining screws, friction coefficient of implant material, and its geometry can have significant effects on the stability of a dental implant system. Two types of dental bridge connections, with a rigid connector and a nonrigid connector, has been constructed and used for experimental verification. A significant displacement difference in premolars are observed. This information will be useful in understanding the manner in which potentially harmful levels of force are transmitted to human bone surrounding dental implants and adjacent teeth, by providing more accurate force input data for finite element models which are under development. This investigation would provide the unique opportunity to combine robotics with dentistry to improve the oral health of patients.
590
$a
School code: 0102.
650
4
$a
Engineering, Mechanical.
$3
783786
650
4
$a
Health Sciences, Dentistry.
$3
1019378
690
$a
0548
690
$a
0567
710
2
$a
University of Kentucky.
$3
1017485
773
0
$t
Dissertation Abstracts International
$g
58-02B.
790
1 0
$a
Sadler, J. Peter,
$e
advisor
790
$a
0102
791
$a
Ph.D.
792
$a
1997
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9722153
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9156954
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入