語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Light-activation influence on the th...
~
Srinivas, Raksha K.
FindBook
Google Book
Amazon
博客來
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer./
作者:
Srinivas, Raksha K.
面頁冊數:
122 p.
附註:
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
Contained By:
Masters Abstracts International48-04.
標題:
Health Sciences, Dentistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1474702
ISBN:
9781109699883
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
Srinivas, Raksha K.
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
- 122 p.
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
Thesis (M.S.)--Marquette University, 2010.
The acid-base and light polymerization reactions in resin modified glass ionomers (RMGI) have been shown to compete and possibly inhibit one another during early RMGI development. Earlier beginning times of light polymerization initiation may limit the acid-base reaction and if time allowed for the acid-base components to react is increased, the extent of light cure reaction may be lesser. The thermal behavior of a commercially available RMGI was investigated in relation to a light initiation regimen using a differential scanning calorimeter (DSC). The relationship between delay in light initiation or no light initiation and the resultant set matrix of the material was determined by subjecting the material to a dynamic temperature scan between 37°C and 300°C at 10°C/min. Different cure groups (n=10 per cure group for an immediate light cure group, 5 min and 10 min delay light cure groups, and a dark cure group) were stored for specific periods of time (30 min, 1 day, 1 week, 1 month and 3 months; n=10/time group) in an incubator at 100% relative humidity and 37°C. Specimen weight changes due to storage and weight loss due to DSC testing were also computed. The DSC thermograms displayed endothermic peaks reflective of material degradation and thus material structure. All groups of specimens had a characteristic single endothermic peak in the thermograms except the 30 min dark cure specimens which had two endothermic peaks in their thermogram. The endothermic peaks were mainly attributed to the dehydration of bound water in the matrix of the material. Significant differences in endothermic peak enthalpy and peak temperature were observed among the cure and time groups. The results suggest that, in general, the immediately light cured material is of differing structure compared to groups that allow the acid-base reaction to occur either due to delay in light curing or its absence. Additionally, changes in the endothermic peak over time were observed, indicating material maturation occurred and is likely due to changes in the ratio of bound to unbound water in the matrix. Interpretation of weight changes in storage show light curing reduced the moisture sensitivity of the RMGI.
ISBN: 9781109699883Subjects--Topical Terms:
1019378
Health Sciences, Dentistry.
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
LDR
:03205nam 2200301 4500
001
1393210
005
20110311132633.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781109699883
035
$a
(UMI)AAI1474702
035
$a
AAI1474702
040
$a
UMI
$c
UMI
100
1
$a
Srinivas, Raksha K.
$3
1671710
245
1 0
$a
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
300
$a
122 p.
500
$a
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
500
$a
Adviser: David W. Berzins.
502
$a
Thesis (M.S.)--Marquette University, 2010.
520
$a
The acid-base and light polymerization reactions in resin modified glass ionomers (RMGI) have been shown to compete and possibly inhibit one another during early RMGI development. Earlier beginning times of light polymerization initiation may limit the acid-base reaction and if time allowed for the acid-base components to react is increased, the extent of light cure reaction may be lesser. The thermal behavior of a commercially available RMGI was investigated in relation to a light initiation regimen using a differential scanning calorimeter (DSC). The relationship between delay in light initiation or no light initiation and the resultant set matrix of the material was determined by subjecting the material to a dynamic temperature scan between 37°C and 300°C at 10°C/min. Different cure groups (n=10 per cure group for an immediate light cure group, 5 min and 10 min delay light cure groups, and a dark cure group) were stored for specific periods of time (30 min, 1 day, 1 week, 1 month and 3 months; n=10/time group) in an incubator at 100% relative humidity and 37°C. Specimen weight changes due to storage and weight loss due to DSC testing were also computed. The DSC thermograms displayed endothermic peaks reflective of material degradation and thus material structure. All groups of specimens had a characteristic single endothermic peak in the thermograms except the 30 min dark cure specimens which had two endothermic peaks in their thermogram. The endothermic peaks were mainly attributed to the dehydration of bound water in the matrix of the material. Significant differences in endothermic peak enthalpy and peak temperature were observed among the cure and time groups. The results suggest that, in general, the immediately light cured material is of differing structure compared to groups that allow the acid-base reaction to occur either due to delay in light curing or its absence. Additionally, changes in the endothermic peak over time were observed, indicating material maturation occurred and is likely due to changes in the ratio of bound to unbound water in the matrix. Interpretation of weight changes in storage show light curing reduced the moisture sensitivity of the RMGI.
590
$a
School code: 0116.
650
4
$a
Health Sciences, Dentistry.
$3
1019378
650
4
$a
Engineering, Materials Science.
$3
1017759
690
$a
0567
690
$a
0794
710
2
$a
Marquette University.
$b
Dentistry.
$3
1671711
773
0
$t
Masters Abstracts International
$g
48-04.
790
1 0
$a
Berzins, David W.,
$e
advisor
790
1 0
$a
Roberts, Howard W.
$e
committee member
790
1 0
$a
Stafford, Gary L.
$e
committee member
790
$a
0116
791
$a
M.S.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1474702
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9156349
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入