An integrated drug-delivery probe with in-line flow measurement.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
An integrated drug-delivery probe with in-line flow measurement./
作者:
Li, Yang.
面頁冊數:
143 p.
附註:
Adviser: Kensall D. Wise.
Contained By:
Dissertation Abstracts International68-02B.
標題:
Engineering, Electronics and Electrical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253330
An integrated drug-delivery probe with in-line flow measurement.
Li, Yang.
An integrated drug-delivery probe with in-line flow measurement.
- 143 p.
Adviser: Kensall D. Wise.
Thesis (Ph.D.)--University of Michigan, 2007.
This research has developed an integrated drug-delivery probe containing an inline thermal flowmeter. Research efforts have focused on improving the probe yield and flowmeter sensitivity. Microchannels for drug delivery are formed in the body of the probe by undercutting a selectively-etched boron-doped silicon and/or dielectric masking structure and then sealing the mask openings using deposited dielectrics. Methods to improve the etching process used for undercutting the channels have been investigated. Channel formation has been explored as a function of etch type, mask opening size, grid width, and screen geometry. Using a screen trench masking structure, together with reducing the previously-used 4mum-wide ribs to 2mum and increasing the trench openings from 1.4mum to 2mum, has improved channel yield to above 90%. In vivo testing has demonstrated their effectiveness and robustness in use.Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
An integrated drug-delivery probe with in-line flow measurement.
LDR
:03583nam 2200265 a 45
001
972751
005
20110928
008
110928s2007 eng d
035
$a
(UMI)AAI3253330
035
$a
AAI3253330
040
$a
UMI
$c
UMI
100
1
$a
Li, Yang.
$3
1296724
245
1 3
$a
An integrated drug-delivery probe with in-line flow measurement.
300
$a
143 p.
500
$a
Adviser: Kensall D. Wise.
500
$a
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 1188.
502
$a
Thesis (Ph.D.)--University of Michigan, 2007.
520
$a
This research has developed an integrated drug-delivery probe containing an inline thermal flowmeter. Research efforts have focused on improving the probe yield and flowmeter sensitivity. Microchannels for drug delivery are formed in the body of the probe by undercutting a selectively-etched boron-doped silicon and/or dielectric masking structure and then sealing the mask openings using deposited dielectrics. Methods to improve the etching process used for undercutting the channels have been investigated. Channel formation has been explored as a function of etch type, mask opening size, grid width, and screen geometry. Using a screen trench masking structure, together with reducing the previously-used 4mum-wide ribs to 2mum and increasing the trench openings from 1.4mum to 2mum, has improved channel yield to above 90%. In vivo testing has demonstrated their effectiveness and robustness in use.
520
$a
Ways to improve the flowmeter sensitivity have been investigated based on thermal modeling, and integrated anemometers with a variety of new features have been designed and fabricated. For polysilicon strip heaters 20mum long, 2mum wide, and 1mum thick having a resistance of 37kO and a temperature coefficient of resistance (TCR) of -5000ppm, the flowmeter produces an output of 40muV/mm/sec over a range of several nL/sec when operating at an input power of 0.18mW with a channel cross-sectional area of 318mum2. A resolution of 1.3nL/sec is achieved, corresponding to a flow velocity of 4.2mm/sec. To further improve flowmeter performance, a process for making buried channels based on a trench refill and CMP process is proposed. Based on this process, a drug-delivery probe with a 50mum2 cross-sectional area and partial- or all-dielectric channel sidewalls, and an integrated flowmeter was fabricated. In vivo testing showed the probe has excellent drug-delivery and neural-recording functions and is appropriate for acute or chronic applications. For a 10mum long, 2mum wide, 1mum thick polysilicon strip heater with a resistance of 16kO and a TCR of -5000ppm, the flowmeter detects 280pL/sec at 0.1mW and 160pL/sec at 0.2mW. In all of these cases, the heater temperature is limited such that the temperature rise in tissue at a distance of 25mum from the probe is less than 2°C, even ignoring capillary cooling. This avoids any possibility of tissue damage due to local heating. For situations where the flowmeter is situated on the back of the probe above the brain cortex and higher local heating can be tolerated for the short times that the flowmeter is active, flow sensitivity can be improved below 100pL/sec while still limiting the temperature rise in tissue to less than 2°C a distance of 200mum below the flowmeter.
590
$a
School code: 0127.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
690
$a
0544
710
2 0
$a
University of Michigan.
$3
777416
773
0
$t
Dissertation Abstracts International
$g
68-02B.
790
$a
0127
790
1 0
$a
Wise, Kensall D.,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253330
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9131008
電子資源
11.線上閱覽_V
電子書
EB W9131008
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入