語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Evaluation of personal aerosol samplers.
~
Aizenberg, Vitaly Alex.
FindBook
Google Book
Amazon
博客來
Evaluation of personal aerosol samplers.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Evaluation of personal aerosol samplers./
作者:
Aizenberg, Vitaly Alex.
面頁冊數:
287 p.
附註:
Chair: Sergey A. Grinshpun.
Contained By:
Dissertation Abstracts International61-09B.
標題:
Environmental Sciences. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9989317
ISBN:
9780599961234
Evaluation of personal aerosol samplers.
Aizenberg, Vitaly Alex.
Evaluation of personal aerosol samplers.
- 287 p.
Chair: Sergey A. Grinshpun.
Thesis (Ph.D.)--University of Cincinnati, 2000.
The first goal of this dissertation was the development, evaluation and validation of the Simplified Protocol for testing of personal inhalable aerosol samplers. Traditionally, personal inhalable aerosol samplers are evaluated in large wind tunnels. This is very time consuming and involves significant operational expenses. A Simplified Test Protocol is described and evaluated here. It was tested in a large conventional and a specially-designed small wind tunnels. The sampling efficiencies of four personal aerosol samplers measured at a variety of sampling conditions according to the conventional approach and the Simplified Protocol in the large and small wind tunnels demonstrated no statistically significant difference. Thus, the Simplified Test Protocol was shown to be suitable for the performance evaluation of personal inhalable aerosol samplers. The Simplified Test Protocol was utilized to measure the sampling efficiencies of the IOM, GSP, and Button Samplers challenged with large (up to 250 mum) particles in the small wind tunnel. The sampling efficiency of the IOM increased with the particle aerodynamic diameter, while that of the GSP and the Button Sampler did not change.
ISBN: 9780599961234Subjects--Topical Terms:
676987
Environmental Sciences.
Evaluation of personal aerosol samplers.
LDR
:03405nam 2200313 a 45
001
967701
005
20110915
008
110915s2000 eng d
020
$a
9780599961234
035
$a
(UMI)AAI9989317
035
$a
AAI9989317
040
$a
UMI
$c
UMI
100
1
$a
Aizenberg, Vitaly Alex.
$3
1291569
245
1 0
$a
Evaluation of personal aerosol samplers.
300
$a
287 p.
500
$a
Chair: Sergey A. Grinshpun.
500
$a
Source: Dissertation Abstracts International, Volume: 61-09, Section: B, page: 4635.
502
$a
Thesis (Ph.D.)--University of Cincinnati, 2000.
520
$a
The first goal of this dissertation was the development, evaluation and validation of the Simplified Protocol for testing of personal inhalable aerosol samplers. Traditionally, personal inhalable aerosol samplers are evaluated in large wind tunnels. This is very time consuming and involves significant operational expenses. A Simplified Test Protocol is described and evaluated here. It was tested in a large conventional and a specially-designed small wind tunnels. The sampling efficiencies of four personal aerosol samplers measured at a variety of sampling conditions according to the conventional approach and the Simplified Protocol in the large and small wind tunnels demonstrated no statistically significant difference. Thus, the Simplified Test Protocol was shown to be suitable for the performance evaluation of personal inhalable aerosol samplers. The Simplified Test Protocol was utilized to measure the sampling efficiencies of the IOM, GSP, and Button Samplers challenged with large (up to 250 mum) particles in the small wind tunnel. The sampling efficiency of the IOM increased with the particle aerodynamic diameter, while that of the GSP and the Button Sampler did not change.
520
$a
The second goal of this dissertation was the laboratory and field evaluation of the Button Sampler as compared to other commercially available aerosol samplers. First, the airflow patterns near the sampler's inlet were studied using the Laser-Doppler Velocimetry. They were found to be similar regardless of the wind velocity and the presence of a stagnation plate simulating a human torso for the sampler facing the wind. The effect of the wind velocity on the Button Sampler's sampling efficiency was found to be statistically significant, while the wind and direction non-significant factor.
520
$a
The heavy metal exposure of workers performing abrasive blasting operations was evaluated based on the personal sampling data obtained with the Button Samplers. The respiratory protection used was found to adequately protect against lead exposure. However, the workers were not adequately protected against cadmium and chromium.
520
$a
A novel application of the Button Sampler, the total enumeration of airborne microorganisms, was investigated. The Button Sampler demonstrated the highest physical collection efficiency, total microbial counts and particle surface density when compared to two commercially available impactor devices. Thus, the Button Sampler is suitable for the enumeration of total airborne spores.
590
$a
School code: 0045.
650
4
$a
Environmental Sciences.
$3
676987
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
690
$a
0354
690
$a
0768
710
2 0
$a
University of Cincinnati.
$3
960309
773
0
$t
Dissertation Abstracts International
$g
61-09B.
790
$a
0045
790
1 0
$a
Grinshpun, Sergey A.,
$e
advisor
791
$a
Ph.D.
792
$a
2000
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9989317
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9126355
電子資源
11.線上閱覽_V
電子書
EB W9126355
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入