Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Numerical calibration techniques and...
~
Li, Lin.
Linked to FindBook
Google Book
Amazon
博客來
Numerical calibration techniques and applications of planar integrated microwave structures.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Numerical calibration techniques and applications of planar integrated microwave structures./
Author:
Li, Lin.
Description:
148 p.
Notes:
Source: Dissertation Abstracts International, Volume: 67-07, Section: B, page: 4000.
Contained By:
Dissertation Abstracts International67-07B.
Subject:
Engineering, Electronics and Electrical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR17004
ISBN:
9780494170045
Numerical calibration techniques and applications of planar integrated microwave structures.
Li, Lin.
Numerical calibration techniques and applications of planar integrated microwave structures.
- 148 p.
Source: Dissertation Abstracts International, Volume: 67-07, Section: B, page: 4000.
Thesis (Ph.D.)--Ecole Polytechnique, Montreal (Canada), 2006.
In this work, a set of numerical thru-reflect-line (TRL) and thru-resistor (TR) calibration techniques are proposed and combined with commercial planar electromagnetic (EM) simulation software. Such numerical calibration techniques are used to eliminate port discontinuities brought by the lumped current/voltage exciting sources in a deterministic method-of-moments (MoM) algorithm. Therefore, accurate equivalent full-wave-based circuit models of the planar discontinuities can be extracted and established for CAD and optimization purposes.
ISBN: 9780494170045Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Numerical calibration techniques and applications of planar integrated microwave structures.
LDR
:03575nam 2200265 a 45
001
965291
005
20110906
008
110906s2006 eng d
020
$a
9780494170045
035
$a
(UnM)AAINR17004
035
$a
AAINR17004
040
$a
UnM
$c
UnM
100
1
$a
Li, Lin.
$3
1020924
245
1 0
$a
Numerical calibration techniques and applications of planar integrated microwave structures.
300
$a
148 p.
500
$a
Source: Dissertation Abstracts International, Volume: 67-07, Section: B, page: 4000.
502
$a
Thesis (Ph.D.)--Ecole Polytechnique, Montreal (Canada), 2006.
520
$a
In this work, a set of numerical thru-reflect-line (TRL) and thru-resistor (TR) calibration techniques are proposed and combined with commercial planar electromagnetic (EM) simulation software. Such numerical calibration techniques are used to eliminate port discontinuities brought by the lumped current/voltage exciting sources in a deterministic method-of-moments (MoM) algorithm. Therefore, accurate equivalent full-wave-based circuit models of the planar discontinuities can be extracted and established for CAD and optimization purposes.
520
$a
The TRL calibration makes use of three standards, namely, through, reflect and line connections. The TRL calibration standards are easy to realize in both practical circuit measurements and numerical EM simulations. The error boxes, which consist of the port discontinuity effects and guided (or feed) line sections from the exciting source planes to DUT (device-under-test), can be set up by using these standards. Then, accurate parameters that electrically characterize the DUT can be obtained. In a TRL calibration procedure, the characteristic impedance of the line standard should be known exactly a priori. To obtain this characteristic impedance for the TRL calibration, a resistor standard is introduced in this work as impedance reference for extracting a three-dimensional (3D) characteristic impedance of the line standard. Generally, the numerical TRL calibration is bandwidth-limited and it is difficult to extend to a scenario of multiport calibration. To remedy this situation, we have proposed numerical 2-port TR and multi-parallel port TR calibration techniques. The 2-port TR calibration procedure deploys through and resistor standards while the multi-parallel port TR calibration uses through, match and multi-resistors standards. Comparing results obtained from our proposed numerical calibration techniques with published results as well as the static modeling results has validated the proposed numerical calibration techniques.
520
$a
With the help of a numerical calibration technique, field-based equivalent circuit models of the port discontinuities are rigorously extracted. Generally, the circuit model of a port discontinuity can be represented by a shunt capacitor and a series inductor. Values of those elements in the circuit model might unfortunately be different when different exciting schemes are applied. From the analysis that is based on a transformation from S parameters to Z or Y parameters, we can observe that a small port discontinuity change can generate huge errors in the extracted equivalent circuit elements of planar circuits and this verily confirms that the calibration is absolutely necessary to remove the errors. (Abstract shortened by UMI.)
590
$a
School code: 1105.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
690
$a
0544
710
2 0
$a
Ecole Polytechnique, Montreal (Canada).
$3
1018606
773
0
$t
Dissertation Abstracts International
$g
67-07B.
790
$a
1105
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR17004
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9124892
電子資源
11.線上閱覽_V
電子書
EB W9124892
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login