Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy./
作者:
Kang, Eunah.
面頁冊數:
129 p.
附註:
Adviser: Kinam Park.
Contained By:
Dissertation Abstracts International68-08B.
標題:
Chemistry, Polymer. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3278677
ISBN:
9780549197843
Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy.
Kang, Eunah.
Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy.
- 129 p.
Adviser: Kinam Park.
Thesis (Ph.D.)--Purdue University, 2007.
Atherosclerosis is the blockage of a blood vessel clogged by fatty substances. To open the clogged vessel, angioplasty is usually performed and a stent is deployed to maintain the vessel open. This procedure, however, causes unwanted event, known as restenosis, in a significant portion of patients. Recent introduction of drug-eluting stents (DESs) minimized the recurrence of restenosis. While two DESs have been used clinically with great successes, there are rooms for improvement. Restenosis is still the problem for some patients and the surface-induced thrombosis is still a major factor for the ultimate failure of the stents. It is important to understand how to control the drug release from DESs to design improved DESs.
ISBN: 9780549197843Subjects--Topical Terms:
1018428
Chemistry, Polymer.
Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy.
LDR
:02632nam 2200301 a 45
001
962753
005
20110830
008
110831s2007 ||||||||||||||||| ||eng d
020
$a
9780549197843
035
$a
(UMI)AAI3278677
035
$a
AAI3278677
040
$a
UMI
$c
UMI
100
1
$a
Kang, Eunah.
$3
1285813
245
1 0
$a
Drug eluting stent and its characterization by coherent anti-Stokes Raman scattering microscopy.
300
$a
129 p.
500
$a
Adviser: Kinam Park.
500
$a
Source: Dissertation Abstracts International, Volume: 68-08, Section: B, page: 5391.
502
$a
Thesis (Ph.D.)--Purdue University, 2007.
520
$a
Atherosclerosis is the blockage of a blood vessel clogged by fatty substances. To open the clogged vessel, angioplasty is usually performed and a stent is deployed to maintain the vessel open. This procedure, however, causes unwanted event, known as restenosis, in a significant portion of patients. Recent introduction of drug-eluting stents (DESs) minimized the recurrence of restenosis. While two DESs have been used clinically with great successes, there are rooms for improvement. Restenosis is still the problem for some patients and the surface-induced thrombosis is still a major factor for the ultimate failure of the stents. It is important to understand how to control the drug release from DESs to design improved DESs.
520
$a
One of the clinically used DESs is TAXUS stent (Boston Scientific, MA) which delivers paclitaxel for periods of months. The mechanisms of paclitaxel release were studied to understand how a drug is released from polymer matrices, and thus to gain insights into the development of the second generation of DESs. During the study, a new microscopic technology, known as coherent anti-Stokes Raman scattering (CARS) microscopy, allows an imaging of three dimensional (3D) distribution of a drug in polymer matrices. CARS images at different depth of a polymer film at time intervals provided information on how a drug is released from the polymer.
520
$a
On the other hand, since the biological events following stent deployment are diverse at temporal phase, it is thought that a drug needs to be delivered at appropriate release kinetics commensurate with a biological process. The current study is also focused on developing the new coating methods to load and release a drug from a stent.
590
$a
School code: 0183.
650
4
$a
Chemistry, Polymer.
$3
1018428
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0495
690
$a
0541
710
2
$a
Purdue University.
$3
1017663
773
0
$t
Dissertation Abstracts International
$g
68-08B.
790
$a
0183
790
1 0
$a
Park, Kinam,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3278677
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9123109
電子資源
11.線上閱覽_V
電子書
EB W9123109
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入