New directions in the design of MRI gradient coils.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
New directions in the design of MRI gradient coils./
作者:
Baig, Tanvir Noor.
面頁冊數:
186 p.
附註:
Adviser: Robert W. Brown.
Contained By:
Dissertation Abstracts International67-12B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3244790
New directions in the design of MRI gradient coils.
Baig, Tanvir Noor.
New directions in the design of MRI gradient coils.
- 186 p.
Adviser: Robert W. Brown.
Thesis (Ph.D.)--Case Western Reserve University, 2007.
In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. The acoustic effects are magnified for high-field Magnetic Resonance Imaging (MRI) scanners because of increased Lorentz forces. Conventional actively shielded gradient assemblies consist of primary and secondary coils in the shape of cylindrical shells surrounding the imaging volume. One of the principal regions of field leakage is at the ends of the gradient structure, and these fields are responsible for substantial eddy current generation. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore.Subjects--Topical Terms:
1017684
Engineering, Biomedical.
New directions in the design of MRI gradient coils.
LDR
:03286nam 2200289 a 45
001
958752
005
20110704
008
110704s2007 ||||||||||||||||| ||eng d
035
$a
(UMI)AAI3244790
035
$a
AAI3244790
040
$a
UMI
$c
UMI
100
1
$a
Baig, Tanvir Noor.
$3
1282209
245
1 0
$a
New directions in the design of MRI gradient coils.
300
$a
186 p.
500
$a
Adviser: Robert W. Brown.
500
$a
Source: Dissertation Abstracts International, Volume: 67-12, Section: B, page: 7122.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2007.
520
$a
In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. The acoustic effects are magnified for high-field Magnetic Resonance Imaging (MRI) scanners because of increased Lorentz forces. Conventional actively shielded gradient assemblies consist of primary and secondary coils in the shape of cylindrical shells surrounding the imaging volume. One of the principal regions of field leakage is at the ends of the gradient structure, and these fields are responsible for substantial eddy current generation. Our new shielded gradient coil designs that feature the inclusion of an endcap have significantly reduced fringe field at the cryostat inner bore. We discuss the degree to which the suppression of peak fringe fields corresponds to a reduction in the acoustic noise generated near the end of the warm bore.
520
$a
Energy efficient capped actively shielded elliptical gradient coils are also designed. In comparison with traditional uncapped elliptical designs the newly proposed design substantially reduces the fringe field at the inner cryostat bore. And compared to a cylindrical design (with a diameter matched to the elliptical semi-major axis), a good reduction in magnetic energy is observed.
520
$a
In addition, a design for a very short, symmetrical, and winged X-gradient insertable head coil is presented. With a smaller radius, an insertable head gradient coil has the advantage of less stored magnetic energy. The corresponding smaller inductance leads to higher slew rates. Lower torque from Lorentz forces is another advantage for these coils. When designing an insertable head coil one must remember the geometry is impacted by the shoulders. In consequence, asymmetric unshielded and shielded designs have been developed. Gradient designs with a shoulder cut-out to achieve longer coil lengths and symmetric and asymmetric insertable head coils with outward flares have all been designed. Gradient characteristics achieved by our designs are compared with a symmetric shoulder cutout design and an asymmetric shielded coil design. Apart from the uniformity along the z-axis direction the new coil achieved characteristics similar to that of coils almost twice its length.
590
$a
School code: 0042.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Physics, General.
$3
1018488
690
$a
0541
690
$a
0605
710
2
$a
Case Western Reserve University.
$3
1017714
773
0
$t
Dissertation Abstracts International
$g
67-12B.
790
$a
0042
790
1 0
$a
Brown, Robert W.,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3244790
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9122217
電子資源
11.線上閱覽_V
電子書
EB W9122217
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入