Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Dispersion reduction on microchip ge...
~
Dutta, Debashis.
Linked to FindBook
Google Book
Amazon
博客來
Dispersion reduction on microchip geometries.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Dispersion reduction on microchip geometries./
Author:
Dutta, Debashis.
Description:
206 p.
Notes:
Director: David T. Leighton, Jr.
Contained By:
Dissertation Abstracts International64-04B.
Subject:
Engineering, Chemical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3088588
Dispersion reduction on microchip geometries.
Dutta, Debashis.
Dispersion reduction on microchip geometries.
- 206 p.
Director: David T. Leighton, Jr.
Thesis (Ph.D.)--University of Notre Dame, 2003.
Over the past decade, numerous chemical and biochemical assays have been demonstrated on microfluidic devices by integrating chemical reactions, separations, sample processing and detection etc., onto the same microchip. In most applications however, the separation unit is an integral part of the analysis system and often determines the overall footprint size of the micro-device. Miniaturization of separation geometries therefore, remains a key issue in the design of such micro-systems and is often limited by solutal dispersion in the analysis channel. One such dominant source for dispersion arises due to electrokinetic flow of solute samples around curved channel geometries. In this case, a shorter path length and a larger analyte velocity along streamlines at smaller radii of curvature, leads to a stretching of the solute slugs. While such dispersion may be reduced by decreasing the channel width around the turn geometry, here we investigate the effect of a sinusoidal wavy inner wall in the curved section.Subjects--Topical Terms:
1018531
Engineering, Chemical.
Dispersion reduction on microchip geometries.
LDR
:04208nam 2200289 a 45
001
937766
005
20110511
008
110511s2003 eng d
035
$a
(UnM)AAI3088588
035
$a
AAI3088588
040
$a
UnM
$c
UnM
100
1
$a
Dutta, Debashis.
$3
1261623
245
1 0
$a
Dispersion reduction on microchip geometries.
300
$a
206 p.
500
$a
Director: David T. Leighton, Jr.
500
$a
Source: Dissertation Abstracts International, Volume: 64-04, Section: B, page: 1820.
502
$a
Thesis (Ph.D.)--University of Notre Dame, 2003.
520
$a
Over the past decade, numerous chemical and biochemical assays have been demonstrated on microfluidic devices by integrating chemical reactions, separations, sample processing and detection etc., onto the same microchip. In most applications however, the separation unit is an integral part of the analysis system and often determines the overall footprint size of the micro-device. Miniaturization of separation geometries therefore, remains a key issue in the design of such micro-systems and is often limited by solutal dispersion in the analysis channel. One such dominant source for dispersion arises due to electrokinetic flow of solute samples around curved channel geometries. In this case, a shorter path length and a larger analyte velocity along streamlines at smaller radii of curvature, leads to a stretching of the solute slugs. While such dispersion may be reduced by decreasing the channel width around the turn geometry, here we investigate the effect of a sinusoidal wavy inner wall in the curved section.
520
$a
Besides electrokinetic dispersion around turn geometries, broadening of analyte bands also occurs during their pressure-driven transport through closed conduits. The no-slip flow condition at the channel walls in such systems leads to the band broadening as convection proceeds in the axial direction. Solutal dispersion in pressure-driven open-channel liquid chromatographic devices also occurs due to similar reasons. In this case however, solute molecules are slowed down near the channel walls both due to the no-slip flow condition as well as their retention in the stationary phase coating the inner walls of the device. While the slug dispersivity arising from such variations in the solute velocity across the channel cross-section scales with the square of the Peclet number based on the narrower dimension of the conduit, its dominant contribution in a large aspect ratio channel geometry results from diffusion limitations in the wider direction. Here, we propose simple modifications in the geometry of the channel side-regions to minimize this contribution in straight channel segments. In addition, we have also examined the use of a pressure-driven back flow to reduce solutal spreading in open-channel liquid electro-chromatographic systems. The imposition of a back flow in such a system tends to speed-up the slow moving molecules near the channel walls by increasing fluid convection around these regions, thereby, minimizing variations in the solute velocity across the channel cross-section.
520
$a
Apart from designing strategies to reduce dispersion on micro-analytic devices, protein separations at prep-scale have also been explored in this dissertation using a novel electrophoretic technique, Binary Oscillatory Cross-Flow Electrophoresis (BOCE). This technique relies on the interaction of an oscillatory electric field and a transverse oscillatory shear flow in the analysis channel. Appropriate selection of frequency and phase of oscillation of the two interacting driving forces provides an effective binary filter that allow proteins, either higher or lower than chosen electrophoretic mobility to pass through the device. While simple binary separations had been demonstrated previously in our research group, the BOCE technique has been extended to ternary separations in our current work.
590
$a
School code: 0165.
650
4
$a
Engineering, Chemical.
$3
1018531
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0542
690
$a
0548
710
2 0
$a
University of Notre Dame.
$3
807615
773
0
$t
Dissertation Abstracts International
$g
64-04B.
790
$a
0165
790
1 0
$a
Leighton, David T., Jr.,
$e
advisor
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3088588
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9108253
電子資源
11.線上閱覽_V
電子書
EB W9108253
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login