語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The particle size distribution and s...
~
Sabty-Daily, Rania Alfred.
FindBook
Google Book
Amazon
博客來
The particle size distribution and speciation of chromium in paint spray aerosol.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
The particle size distribution and speciation of chromium in paint spray aerosol./
作者:
Sabty-Daily, Rania Alfred.
面頁冊數:
178 p.
附註:
Chair: John R. Froines.
Contained By:
Dissertation Abstracts International62-08B.
標題:
Environmental Sciences. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3024125
ISBN:
0493362347
The particle size distribution and speciation of chromium in paint spray aerosol.
Sabty-Daily, Rania Alfred.
The particle size distribution and speciation of chromium in paint spray aerosol.
- 178 p.
Chair: John R. Froines.
Thesis (Ph.D.)--University of California, Los Angeles, 2001.
Workplace exposures to hexavalent chromium [Cr(VI)], a human carcinogen, are significant in spraying operations of chromate-containing paints. This research sought to clarify issues related to the analysis of Cr(VI) in paint samples, to assess the size distribution and speciation of chromium (Cr) in the field, and to evaluate the effect of spray application parameters on paint aerosol size distribution. Accurate determination of Cr(VI) in paint aerosol air samples is important in assessing a worker's exposure to Cr(VI). The efficiency of a widely used procedure published in National Institute of Occupational Safety and Health method 7604 at extracting Cr(VI) from paint samples was determined. This extraction was historically validated for paint samples containing 24.5 to 61.5 μg of Cr(VI). Actual Cr(VI) mass in paint samples collected in industrial settings may be greater than 61.5 μg. Paint samples containing 250 to 3000 μg of Cr(VI) were extracted and analyzed for Cr(VI) and total Cr. A significant decrease in Cr(VI) extraction efficiency was determined for samples containing more than 1000 μg of Cr(VI). Cr(VI) was stable in refrigerated samples and in paint cans.
ISBN: 0493362347Subjects--Topical Terms:
676987
Environmental Sciences.
The particle size distribution and speciation of chromium in paint spray aerosol.
LDR
:03199nam 2200301 a 45
001
936515
005
20110510
008
110510s2001 eng d
020
$a
0493362347
035
$a
(UnM)AAI3024125
035
$a
AAI3024125
040
$a
UnM
$c
UnM
100
1
$a
Sabty-Daily, Rania Alfred.
$3
1260202
245
1 0
$a
The particle size distribution and speciation of chromium in paint spray aerosol.
300
$a
178 p.
500
$a
Chair: John R. Froines.
500
$a
Source: Dissertation Abstracts International, Volume: 62-08, Section: B, page: 3566.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2001.
520
$a
Workplace exposures to hexavalent chromium [Cr(VI)], a human carcinogen, are significant in spraying operations of chromate-containing paints. This research sought to clarify issues related to the analysis of Cr(VI) in paint samples, to assess the size distribution and speciation of chromium (Cr) in the field, and to evaluate the effect of spray application parameters on paint aerosol size distribution. Accurate determination of Cr(VI) in paint aerosol air samples is important in assessing a worker's exposure to Cr(VI). The efficiency of a widely used procedure published in National Institute of Occupational Safety and Health method 7604 at extracting Cr(VI) from paint samples was determined. This extraction was historically validated for paint samples containing 24.5 to 61.5 μg of Cr(VI). Actual Cr(VI) mass in paint samples collected in industrial settings may be greater than 61.5 μg. Paint samples containing 250 to 3000 μg of Cr(VI) were extracted and analyzed for Cr(VI) and total Cr. A significant decrease in Cr(VI) extraction efficiency was determined for samples containing more than 1000 μg of Cr(VI). Cr(VI) was stable in refrigerated samples and in paint cans.
520
$a
Field studies were conducted to determine the size distribution and speciation of Cr in paint spray aerosol using personal cascade impactors. The Cr(VI) size distributions had a mean MMD of 15 μm. Cr in the paint aerosol was essentially in the Cr(VI) form. Particles larger than 10 μm accounted for most of the aerosol mass. Cr(VI) in paint spray aerosol was estimated to deposit mostly in the head airways of the respiratory system. This could explain the cases of the upper respiratory cancer reported in the literature among spray painters, and the weak or negative associations reported in epidemiologic studies between lung cancer and paint spraying.
520
$a
The size distribution of paint spray aerosol generated in a laboratory-based miniature spray paint booth had a MMD ranging from 4.2 to 9.6 μm. Particle bounce inside the cascade impactor did not affect particle size distribution. Bounceback spray generated smaller particles than direct spray. Aerosol aging had no effect on size distribution. Gun atomization pressure and aerosol size were inversely related.
590
$a
School code: 0031.
650
4
$a
Environmental Sciences.
$3
676987
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
690
$a
0354
690
$a
0768
710
2 0
$a
University of California, Los Angeles.
$3
626622
773
0
$t
Dissertation Abstracts International
$g
62-08B.
790
$a
0031
790
1 0
$a
Froines, John R.,
$e
advisor
791
$a
Ph.D.
792
$a
2001
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3024125
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9107101
電子資源
11.線上閱覽_V
電子書
EB W9107101
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入