語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Human tear protein analysis, and fac...
~
Ng, Sheung-Shun Vincent.
FindBook
Google Book
Amazon
博客來
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins./
作者:
Ng, Sheung-Shun Vincent.
面頁冊數:
286 p.
附註:
Adviser: Pauline Cho.
Contained By:
Dissertation Abstracts International63-10B.
標題:
Health Sciences, Ophthalmology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3066468
ISBN:
0493859217
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins.
Ng, Sheung-Shun Vincent.
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins.
- 286 p.
Adviser: Pauline Cho.
Thesis (Ph.D.)--Hong Kong Polytechnic (People's Republic of China), 2002.
Although different values of TTPC were obtained with different methods/standards used, their values were found correlated well with each other. Our results showed good agreements between the measured and the calculated TTPC.
ISBN: 0493859217Subjects--Topical Terms:
1019445
Health Sciences, Ophthalmology.
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins.
LDR
:03793nam 2200349 a 45
001
933965
005
20110509
008
110509s2002 eng d
020
$a
0493859217
035
$a
(UnM)AAI3066468
035
$a
AAI3066468
040
$a
UnM
$c
UnM
100
1
$a
Ng, Sheung-Shun Vincent.
$3
1257694
245
1 0
$a
Human tear protein analysis, and factors affecting the concentrations of total and individual tear proteins.
300
$a
286 p.
500
$a
Adviser: Pauline Cho.
500
$a
Source: Dissertation Abstracts International, Volume: 63-10, Section: B, page: 4608.
502
$a
Thesis (Ph.D.)--Hong Kong Polytechnic (People's Republic of China), 2002.
520
$a
Although different values of TTPC were obtained with different methods/standards used, their values were found correlated well with each other. Our results showed good agreements between the measured and the calculated TTPC.
520
$a
There were no significant daytime and between-day variations in TTPC and the individual tear proteins, except for the concentration of HSA. The eye-flush method consistently showed greater variability than the yawn method.
520
$a
The objectives of this study were to analyze human tear protein profiles, and to investigate the factors affecting the total tear protein concentration (TTPC) and the individual proteins. Tear samples were collected (using capillary tube) from young normal Hong Kong-Chinese and TTPC and individual protein concentrations were determined.
520
$a
In the main studies, we determined the tear protein levels of young Hong Kong-Chinese. The results of TTPC obtained using different methods (Bradford or Lowry) and standards (bovine serum albumin (BSA) and bovine immunoglobulin G (IgG)) were compared, and their relationships were determined.
520
$a
The Bradford and Lowry methods were repeatable in the determination of TTPC. The technique of SDS-PAGE was found to have clinically acceptable repeatability in the determination of lactoferrin, lysozyme and tear specific prealbumin (TSP). However, the variability of immunoglobulin A (sIgA) and human serum albumin (HSA) levels were of clinical significance.
520
$a
For the Bradford method using BSA and IgG as standards, the mean TTPC were 6.05 ± 1.58 and 11.48 ± 2.32 mg/ml respectively. For the Lowry method using BSA and IgG as standards, the mean TTPC were 9.66 ± 2.03 and 7.53 ± 1.80 mg/ml respectively. Using SDS-PAGE, protein bands of sIgA, lactoferrin, HSA, TSP and lysozyme were separated. The mean concentrations of sIgA and lactoferrin were 0.29 ± 0.10 and 2.73 ± 0.82 mg/ml respectively. The mean concentrations of HSA, TSP and lysozyme were 0.021 ± 0.028, 2.89 ± 0.88 and 2.46 ± 0.44 mg/ml respectively.
520
$a
Using known concentration artificial tear protein mixtures to simulate tears from normal and dry eye subjects, we found a standard comprising a mixture of 50% BSA and 50% IgG would provide a more accurate and better estimation of TTPC than if either BSA or IgG was used. For the Lowry method, using either IgG or IgA as standard would give more accurate results than using BSA, HSA or lysozyme standards.
520
$a
We did not observed any significant difference in the tear protein profiles between contact lens (n = 14) and non-contact lens (n = 14) wearers. There were no significant changes in tear protein levels before and after contact lens wear (both soft (n = 7) and rigid (n = 7) lens wear). (Abstract shortened by UMI.)
590
$a
School code: 1170.
650
4
$a
Health Sciences, Ophthalmology.
$3
1019445
690
$a
0381
710
2 0
$a
Hong Kong Polytechnic (People's Republic of China).
$3
1249353
773
0
$t
Dissertation Abstracts International
$g
63-10B.
790
$a
1170
790
1 0
$a
Cho, Pauline,
$e
advisor
791
$a
Ph.D.
792
$a
2002
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3066468
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9104562
電子資源
11.線上閱覽_V
電子書
EB W9104562
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入