Cold fiber solid phase microextraction.
~
University of Waterloo (Canada).
FindBook
Google Book
Amazon
博客來
Cold fiber solid phase microextraction.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Cold fiber solid phase microextraction./
作者:
Hosseinzadeh Haddadi, Shokouh.
面頁冊數:
158 p.
附註:
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: .
Contained By:
Dissertation Abstracts International69-11B.
標題:
Chemistry, Analytical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR43276
ISBN:
9780494432761
Cold fiber solid phase microextraction.
Hosseinzadeh Haddadi, Shokouh.
Cold fiber solid phase microextraction.
- 158 p.
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: .
Thesis (Ph.D.)--University of Waterloo (Canada), 2008.
A cold fiber solid phase microextraction device was designed and constructed based on the use of a thermoelectric cooler (TEC). A three-stage thermoelectric cooler was used for cooling a copper rod coated with a polydimethylsiloxane (PDMS) hollow fiber, which served as the SPME fiber. The copper rod was mounted on a commercial SPME plunger and exposed to the cold surface of the TEC, which was enclosed in a small aluminum box. A heat sink and a fan dissipated the generated heat at the hot side of the TEC. By applying an appropriate DC voltage to the TEC, the upper part of the copper rod, which was in contact to the cold side of the TEC, was cooled and the hollow fiber reached a lower temperature through heat transfer. A thermocouple was embedded in the cold side of the TEC for indirect measurement of the fiber temperature. A portable cold fiber SPME device was made by using a car battery as the power supply.
ISBN: 9780494432761Subjects--Topical Terms:
586156
Chemistry, Analytical.
Cold fiber solid phase microextraction.
LDR
:04187nmm 2200289 a 45
001
867339
005
20100804
008
100804s2008 ||||||||||||||||| ||eng d
020
$a
9780494432761
035
$a
(UMI)AAINR43276
035
$a
AAINR43276
040
$a
UMI
$c
UMI
100
1
$a
Hosseinzadeh Haddadi, Shokouh.
$3
1036065
245
1 0
$a
Cold fiber solid phase microextraction.
300
$a
158 p.
500
$a
Source: Dissertation Abstracts International, Volume: 69-11, Section: B, page: .
502
$a
Thesis (Ph.D.)--University of Waterloo (Canada), 2008.
520
$a
A cold fiber solid phase microextraction device was designed and constructed based on the use of a thermoelectric cooler (TEC). A three-stage thermoelectric cooler was used for cooling a copper rod coated with a polydimethylsiloxane (PDMS) hollow fiber, which served as the SPME fiber. The copper rod was mounted on a commercial SPME plunger and exposed to the cold surface of the TEC, which was enclosed in a small aluminum box. A heat sink and a fan dissipated the generated heat at the hot side of the TEC. By applying an appropriate DC voltage to the TEC, the upper part of the copper rod, which was in contact to the cold side of the TEC, was cooled and the hollow fiber reached a lower temperature through heat transfer. A thermocouple was embedded in the cold side of the TEC for indirect measurement of the fiber temperature. A portable cold fiber SPME device was made by using a car battery as the power supply.
520
$a
The cold fiber SPME device with thermoelectric cooling was applied in quantitative analysis of off-flavors in rice. Hexanal, nonanal, and undecanal were chosen as three test analytes in rice. These analytes were identified according to their retention times and analyzed with a GC/FID instrument. Headspace extraction conditions (i.e. extraction temperature and extraction time) were optimized. Standard addition calibration graphs were obtained at the optimized conditions and the concentrations of the three analytes were calculated. The developed method was compared to a conventional solvent extraction method.
520
$a
The applicability of the portable cold fiber SPME with TEC for field sampling was tested. The effect of cooling on extraction recovery and the reproducibility of extraction were examined for extractions from an n-alkane flow through system. It was found that the extraction recoveries were significantly higher when the fiber was cooled. To further investigate the effect of cooling on the sensitivity of SPME in field sampling, the portable cold fiber SPME was used for extraction of volatile components from living wisteria flowers. Both the number of identified compounds and the related peak areas increased for extractions with cold PDMS fiber relative to without cooling and commercial PDMS and PA fibers. The portable cold fiber SPME device was also used for field sampling of volatile components of living lily-of-the-valley flowers and the extracted compounds were analyzed with GC/MS.
520
$a
The desorption kinetics of hydrophobic organic compounds (HOCs) from environmental solid matrices was investigated using cold fiber SPME with CO 2 cooling. Polycyclic aromatic hydrocarbons (PAHs) and selected volatile organic compounds (i.e. toluene, ethylbenzene, o-xylene) were used as test analytes. Sand, silica gel, and clay were used as laboratory model solid matrices and were contaminated by the test analytes. Certified sediments were used as naturally contaminated samples. In this approach, the organic compounds, released from contaminated solid samples at different elevated temperatures, were exhaustively extracted with cold fiber SPME over different extraction times. The extraction data were used to obtain desorption and Arrhenius plots. The rate constants of desorption and activation energies of desorption were measured for each contaminant using these plots. The results were comparable to those reported in the literature.
590
$a
School code: 1141.
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Physical.
$3
560527
690
$a
0486
690
$a
0494
710
2
$a
University of Waterloo (Canada).
$3
1017669
773
0
$t
Dissertation Abstracts International
$g
69-11B.
790
$a
1141
791
$a
Ph.D.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR43276
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9078817
電子資源
11.線上閱覽_V
電子書
EB W9078817
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入