語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Improving corrosion resistance of po...
~
Schokker, Andrea Jeanne.
FindBook
Google Book
Amazon
博客來
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts./
作者:
Schokker, Andrea Jeanne.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 1999,
面頁冊數:
314 p.
附註:
Source: Dissertations Abstracts International, Volume: 61-06, Section: B.
Contained By:
Dissertations Abstracts International61-06B.
標題:
Civil engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9947379
ISBN:
9780599495470
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts.
Schokker, Andrea Jeanne.
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts.
- Ann Arbor : ProQuest Dissertations & Theses, 1999 - 314 p.
Source: Dissertations Abstracts International, Volume: 61-06, Section: B.
Thesis (Ph.D.)--The University of Texas at Austin, 1999.
The use of post-tensioning in bridges can provide durability and structural benefits to the system while expediting the construction process. When post-tensioning is combined with precast elements, traffic interference can be greatly reduced through rapid construction. Post-tensioned concrete substructure elements such as bridge piers, hammerhead bents, and straddle bents have become more prevalent in recent years. Chloride induced corrosion of steel in concrete is one of the most costly forms of corrosion each year. Coastal substructure elements are exposed to seawater by immersion or spray, and inland bridges may also be at risk due to the application of deicing salts. Corrosion protection of the post-tensioning system is vital to the integrity of the structure because loss of post-tensioning can result in catastrophic failure. Documentation for durability design of the grout, ducts, and anchorage systems is very limited. The objective of this research is to evaluate the effectiveness of corrosion protection measures for post-tensioned concrete substructures by designing and testing specimens representative of typical substructure elements using state-of-the-art practices in aggressive chloride exposure environments. This was accomplished through exposure testing of twenty-seven large-scale beam specimens and ten large-scale column specimens. High performance grout for post-tensioning tendon injection was also developed through a series of fresh property tests, accelerated exposure tests, and a large-scale pumping test to simulate field conditions. A high performance fly ash grout was developed for applications with small vertical rises, and a high performance anti-bleed grout was developed for applications involving large vertical rises such as tall bridge piers. Long-term exposure testing of the beam and column specimens is ongoing, but preliminary findings indicate increased corrosion protection with increasing levels of post-tensioning, although traditional fully prestressed sections may not give as high a benefit to cost ratio as partially prestressed sections with high percentages of prestressing steel. Specimens with low permeable concrete are showing better corrosion protection than specimens with the standard concrete for bridge substructures used by the Texas Department of Transportation. Recommendations and guidelines for durable design of post-tensioned bridge substructures were developed from the findings to date, and supplementary information will be provided after final autopsy of all specimens.
ISBN: 9780599495470Subjects--Topical Terms:
860360
Civil engineering.
Subjects--Index Terms:
Corrosion resistance
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts.
LDR
:03754nmm a2200385 4500
001
2403823
005
20241125080229.5
006
m o d
007
cr#unu||||||||
008
251215s1999 ||||||||||||||||| ||eng d
020
$a
9780599495470
035
$a
(MiAaPQ)AAI9947379
035
$a
AAI9947379
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Schokker, Andrea Jeanne.
$3
3774104
245
1 0
$a
Improving corrosion resistance of post -tensioned substructures emphasizing high performance grouts.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
1999
300
$a
314 p.
500
$a
Source: Dissertations Abstracts International, Volume: 61-06, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Breen, John E.
502
$a
Thesis (Ph.D.)--The University of Texas at Austin, 1999.
520
$a
The use of post-tensioning in bridges can provide durability and structural benefits to the system while expediting the construction process. When post-tensioning is combined with precast elements, traffic interference can be greatly reduced through rapid construction. Post-tensioned concrete substructure elements such as bridge piers, hammerhead bents, and straddle bents have become more prevalent in recent years. Chloride induced corrosion of steel in concrete is one of the most costly forms of corrosion each year. Coastal substructure elements are exposed to seawater by immersion or spray, and inland bridges may also be at risk due to the application of deicing salts. Corrosion protection of the post-tensioning system is vital to the integrity of the structure because loss of post-tensioning can result in catastrophic failure. Documentation for durability design of the grout, ducts, and anchorage systems is very limited. The objective of this research is to evaluate the effectiveness of corrosion protection measures for post-tensioned concrete substructures by designing and testing specimens representative of typical substructure elements using state-of-the-art practices in aggressive chloride exposure environments. This was accomplished through exposure testing of twenty-seven large-scale beam specimens and ten large-scale column specimens. High performance grout for post-tensioning tendon injection was also developed through a series of fresh property tests, accelerated exposure tests, and a large-scale pumping test to simulate field conditions. A high performance fly ash grout was developed for applications with small vertical rises, and a high performance anti-bleed grout was developed for applications involving large vertical rises such as tall bridge piers. Long-term exposure testing of the beam and column specimens is ongoing, but preliminary findings indicate increased corrosion protection with increasing levels of post-tensioning, although traditional fully prestressed sections may not give as high a benefit to cost ratio as partially prestressed sections with high percentages of prestressing steel. Specimens with low permeable concrete are showing better corrosion protection than specimens with the standard concrete for bridge substructures used by the Texas Department of Transportation. Recommendations and guidelines for durable design of post-tensioned bridge substructures were developed from the findings to date, and supplementary information will be provided after final autopsy of all specimens.
590
$a
School code: 0227.
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Ocean engineering.
$3
660731
650
4
$a
Materials science.
$3
543314
653
$a
Corrosion resistance
653
$a
Grouts
653
$a
Post-tensioned
653
$a
Substructures
690
$a
0543
690
$a
0547
690
$a
0794
710
2
$a
The University of Texas at Austin.
$3
718984
773
0
$t
Dissertations Abstracts International
$g
61-06B.
790
$a
0227
791
$a
Ph.D.
792
$a
1999
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9947379
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9512143
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入