語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Mitigating Signal Loss in Force-Grad...
~
Boucher, Michael Claude.
FindBook
Google Book
Amazon
博客來
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance./
作者:
Boucher, Michael Claude.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
263 p.
附註:
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Contained By:
Dissertations Abstracts International85-07B.
標題:
Physical chemistry. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30527698
ISBN:
9798381412406
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
Boucher, Michael Claude.
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 263 p.
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Thesis (Ph.D.)--Cornell University, 2023.
The ability to use magnetic resonance to detect and image free radical spin labels will enable structural determination from individual spin-labeled biomolecules and biomolecular complexes. In 2004, single electron magnetic resonance detection was first demonstrated using Magnetic Resonance Force Microscopy (MRFM), a technique in which sample magnetization is detected as a force, or force gradient, on a high-sensitivity cantilever. However, this 2004 measurement required a highly specialized sample and long acquisition times. More recently, a force-gradient detection scheme, Cantilever Enabled Readout of Magnetization Inversion Transients (CERMIT), more applicable to the short coherence times of spin labels, has been developed. In CERMIT the cantilever is self-oscillated, and the signal is the cantilever frequency shift. In this dissertation, we discuss the development of a new approach to sample preparation for CERMIT experiments. While the primary limitation to MRFM sensitivity is surface noise, coating the polymer sample with metal decreases sample frequency noise by a significant factor. We use MRFM and inductively detected measurements to show that the deposition of this metallic overlayer damages or inactivates nitroxide spin labels at the top of the sample. Our new approach to sample preparation deposits the gold metal layer onto a sacrificial polymer instead of directly onto the sensitive radicals. We perform MRFM measurements on this new "laminate" sample using a cantilever with a nanoscale tip and show a 20-fold increase in spin signal. While this increase in signal size is highly significant, it is still an order of magnitude smaller than predicted by simulations. In this dissertation we will also investigate possible reasons for the reduced signal size in this experiment and previous measurements that were performed with nanoscale magnetic tips. We explore the effects of poor tip field gradients from magnet damage, of spin-lattice relaxation due to tip magnetization fluctuations, and incomplete saturation of sample spins due to the motion of the magnetic tip. We use the Bloch equations to derive an expression for the saturation and incorporate this new expression into the simulation code. We show that the results are significantly better than previous simulations at matching experimental signals from both micron-scale and nanoscale magnetic tips.
ISBN: 9798381412406Subjects--Topical Terms:
1981412
Physical chemistry.
Subjects--Index Terms:
Electron spin resonance
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
LDR
:03626nmm a2200409 4500
001
2403572
005
20241118135834.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798381412406
035
$a
(MiAaPQ)AAI30527698
035
$a
AAI30527698
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Boucher, Michael Claude.
$0
(orcid)0000-0001-6540-7379
$3
3773843
245
1 0
$a
Mitigating Signal Loss in Force-Gradient Detection of Electron Spin Resonance.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
263 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
500
$a
Advisor: Marohn, John.
502
$a
Thesis (Ph.D.)--Cornell University, 2023.
520
$a
The ability to use magnetic resonance to detect and image free radical spin labels will enable structural determination from individual spin-labeled biomolecules and biomolecular complexes. In 2004, single electron magnetic resonance detection was first demonstrated using Magnetic Resonance Force Microscopy (MRFM), a technique in which sample magnetization is detected as a force, or force gradient, on a high-sensitivity cantilever. However, this 2004 measurement required a highly specialized sample and long acquisition times. More recently, a force-gradient detection scheme, Cantilever Enabled Readout of Magnetization Inversion Transients (CERMIT), more applicable to the short coherence times of spin labels, has been developed. In CERMIT the cantilever is self-oscillated, and the signal is the cantilever frequency shift. In this dissertation, we discuss the development of a new approach to sample preparation for CERMIT experiments. While the primary limitation to MRFM sensitivity is surface noise, coating the polymer sample with metal decreases sample frequency noise by a significant factor. We use MRFM and inductively detected measurements to show that the deposition of this metallic overlayer damages or inactivates nitroxide spin labels at the top of the sample. Our new approach to sample preparation deposits the gold metal layer onto a sacrificial polymer instead of directly onto the sensitive radicals. We perform MRFM measurements on this new "laminate" sample using a cantilever with a nanoscale tip and show a 20-fold increase in spin signal. While this increase in signal size is highly significant, it is still an order of magnitude smaller than predicted by simulations. In this dissertation we will also investigate possible reasons for the reduced signal size in this experiment and previous measurements that were performed with nanoscale magnetic tips. We explore the effects of poor tip field gradients from magnet damage, of spin-lattice relaxation due to tip magnetization fluctuations, and incomplete saturation of sample spins due to the motion of the magnetic tip. We use the Bloch equations to derive an expression for the saturation and incorporate this new expression into the simulation code. We show that the results are significantly better than previous simulations at matching experimental signals from both micron-scale and nanoscale magnetic tips.
590
$a
School code: 0058.
650
4
$a
Physical chemistry.
$3
1981412
650
4
$a
Materials science.
$3
543314
650
4
$a
Electromagnetics.
$3
3173223
650
4
$a
Nanoscience.
$3
587832
653
$a
Electron spin resonance
653
$a
Magnetic resonance force microscopy
653
$a
Magnetometry
653
$a
Nanofabrication
653
$a
Spin label
653
$a
Surface-induced dissipation
690
$a
0494
690
$a
0794
690
$a
0565
690
$a
0607
710
2
$a
Cornell University.
$b
Chemistry and Chemical Biology.
$3
3281129
773
0
$t
Dissertations Abstracts International
$g
85-07B.
790
$a
0058
791
$a
Ph.D.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30527698
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9511892
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入