語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Superconducting Microwave Resonator ...
~
Noroozian, Omid,
FindBook
Google Book
Amazon
博客來
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging // Omid Noroozian.
作者:
Noroozian, Omid,
面頁冊數:
1 electronic resource (189 pages)
附註:
Source: Dissertations Abstracts International, Volume: 74-01, Section: B.
Contained By:
Dissertations Abstracts International74-01B.
標題:
Electrical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3512519
ISBN:
9781267416094
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging /
Noroozian, Omid,
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging /
Omid Noroozian. - 1 electronic resource (189 pages)
Source: Dissertations Abstracts International, Volume: 74-01, Section: B.
Superconducting microwave resonators have the potential to revolutionize submillimeter and far-infrared astronomy, and with it our understanding of the universe. The field of low-temperature detector technology has reached a point where extremely sensitive devices like transition-edge sensors are now capable of detecting radiation limited by the background noise of the universe. However, the size of these detector arrays are limited to only a few thousand pixels. This is because of the cost and complexity of fabricating large-scale arrays of these detectors that can reach up to 10 lithographic levels on chip, and the complicated SQUID-based multiplexing circuitry and wiring for readout of each detector. In order to make substantial progress, next-generation ground-based telescopes such as CCAT or future space telescopes require focal planes with large-scale detector arrays of 104-10 6 pixels. Arrays using microwave kinetic inductance detectors (MKID) are a potential solution. These arrays can be easily made with a single layer of superconducting metal film deposited on a silicon substrate and pattered using conventional optical lithography. Furthermore, MKIDs are inherently multiplexable in the frequency domain, allowing ∼ 10 3 detectors to be read out using a single coaxial transmission line and cryogenic amplifier, drastically reducing cost and complexity. An MKID uses the change in the microwave surface impedance of a superconducting thin-film microresonator to detect photons. Absorption of photons in the superconductor breaks Cooper pairs into quasiparticles, changing the complex surface impedance, which results in a perturbation of resonator frequency and quality factor. For excitation and readout, the resonator is weakly coupled to a transmission line. The complex amplitude of a microwave probe signal tuned on-resonance and transmitted on the feedline past the resonator is perturbed as photons are absorbed in the superconductor. The perturbation can be detected using a cryogenic amplifier and subsequent homodyne mixing at room temperature. In an array of MKIDs, all the resonators are coupled to a shared feedline and are tuned to slightly different frequencies. They can be read out simultaneously using a comb of frequencies generated and measured using digital techniques. This thesis documents an effort to demonstrate the basic operation of ∼ 256 pixel arrays of lumped-element MKIDs made from superconducting TiN x on silicon. The resonators are designed and simulated for optimum operation. Various properties of the resonators and arrays are measured and compared to theoretical expectations. A particularly exciting observation is the extremely high quality factors (∼ 3 x 107) of our TiNx resonators which is essential for ultra-high sensitivity. The arrays are tightly packed both in space and in frequency which is desirable for larger full-size arrays. However, this can cause a serious problem in terms of microwave crosstalk between neighboring pixels. We show that by properly designing the resonator geometry, crosstalk can be eliminated; this is supported by our measurement results. We also tackle the problem of excess frequency noise in MKIDs. Intrinsic noise in the form of an excess resonance frequency jitter exists in planar superconducting resonators that are made on dielectric substrates. We conclusively show that this noise is due to fluctuations of the resonator capacitance. In turn, the capacitance fluctuations are thought to be driven by two-level system (TLS) fluctuators in a thin layer on the surface of the device. With a modified resonator design we demonstrate with measurements that this noise can be substantially reduced. An optimized version of this resonator was designed for the multiwavelength submillimeter kinetic inductance camera (MUSIC) instrument for the Caltech Submillimeter Observatory.
English
ISBN: 9781267416094Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Astronomical instrumentation
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging /
LDR
:05589nmm a22004813i 4500
001
2401787
005
20250522102108.5
006
m o d
007
cr|nu||||||||
008
251215s2012 miu||||||m |||||||eng d
020
$a
9781267416094
035
$a
(MiAaPQD)AAI3512519
035
$a
(MiAaPQD)caltech:10247
035
$a
AAI3512519
035
$a
2401787
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Noroozian, Omid,
$e
author.
$3
3771984
245
1 0
$a
Superconducting Microwave Resonator Arrays for Submillimeter/Far-Infrared Imaging /
$c
Omid Noroozian.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2012
300
$a
1 electronic resource (189 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 74-01, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisors: Zmuidzinas, Jonas Committee members: Golwala, Sunil; Hajimiri, Ali; Rutledge, David; Weinreb, Sander; Zmuidzinas, Jonas.
502
$b
Ph.D.
$c
California Institute of Technology
$d
2012.
520
$a
Superconducting microwave resonators have the potential to revolutionize submillimeter and far-infrared astronomy, and with it our understanding of the universe. The field of low-temperature detector technology has reached a point where extremely sensitive devices like transition-edge sensors are now capable of detecting radiation limited by the background noise of the universe. However, the size of these detector arrays are limited to only a few thousand pixels. This is because of the cost and complexity of fabricating large-scale arrays of these detectors that can reach up to 10 lithographic levels on chip, and the complicated SQUID-based multiplexing circuitry and wiring for readout of each detector. In order to make substantial progress, next-generation ground-based telescopes such as CCAT or future space telescopes require focal planes with large-scale detector arrays of 104-10 6 pixels. Arrays using microwave kinetic inductance detectors (MKID) are a potential solution. These arrays can be easily made with a single layer of superconducting metal film deposited on a silicon substrate and pattered using conventional optical lithography. Furthermore, MKIDs are inherently multiplexable in the frequency domain, allowing ∼ 10 3 detectors to be read out using a single coaxial transmission line and cryogenic amplifier, drastically reducing cost and complexity. An MKID uses the change in the microwave surface impedance of a superconducting thin-film microresonator to detect photons. Absorption of photons in the superconductor breaks Cooper pairs into quasiparticles, changing the complex surface impedance, which results in a perturbation of resonator frequency and quality factor. For excitation and readout, the resonator is weakly coupled to a transmission line. The complex amplitude of a microwave probe signal tuned on-resonance and transmitted on the feedline past the resonator is perturbed as photons are absorbed in the superconductor. The perturbation can be detected using a cryogenic amplifier and subsequent homodyne mixing at room temperature. In an array of MKIDs, all the resonators are coupled to a shared feedline and are tuned to slightly different frequencies. They can be read out simultaneously using a comb of frequencies generated and measured using digital techniques. This thesis documents an effort to demonstrate the basic operation of ∼ 256 pixel arrays of lumped-element MKIDs made from superconducting TiN x on silicon. The resonators are designed and simulated for optimum operation. Various properties of the resonators and arrays are measured and compared to theoretical expectations. A particularly exciting observation is the extremely high quality factors (∼ 3 x 107) of our TiNx resonators which is essential for ultra-high sensitivity. The arrays are tightly packed both in space and in frequency which is desirable for larger full-size arrays. However, this can cause a serious problem in terms of microwave crosstalk between neighboring pixels. We show that by properly designing the resonator geometry, crosstalk can be eliminated; this is supported by our measurement results. We also tackle the problem of excess frequency noise in MKIDs. Intrinsic noise in the form of an excess resonance frequency jitter exists in planar superconducting resonators that are made on dielectric substrates. We conclusively show that this noise is due to fluctuations of the resonator capacitance. In turn, the capacitance fluctuations are thought to be driven by two-level system (TLS) fluctuators in a thin layer on the surface of the device. With a modified resonator design we demonstrate with measurements that this noise can be substantially reduced. An optimized version of this resonator was designed for the multiwavelength submillimeter kinetic inductance camera (MUSIC) instrument for the Caltech Submillimeter Observatory.
546
$a
English
590
$a
School code: 0037
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Astrophysics.
$3
535904
650
4
$a
Low temperature physics.
$3
3173917
653
$a
Astronomical instrumentation
653
$a
Microwave resonators
653
$a
Photon detectors
653
$a
Submillimeter imaging
653
$a
Superconducting detectors
653
$a
sKinetic inductance detectors
690
$a
0544
690
$a
0596
690
$a
0598
710
2
$a
California Institute of Technology.
$b
Electrical Engineering.
$e
degree granting institution.
$3
3771985
720
1
$a
Zmuidzinas, Jonas
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
74-01B.
790
$a
0037
791
$a
Ph.D.
792
$a
2012
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3512519
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9510107
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入