A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues./
作者:
Karakan, M. Cagatay.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
200 p.
附註:
Source: Dissertations Abstracts International, Volume: 84-07, Section: B.
Contained By:
Dissertations Abstracts International84-07B.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30244820
ISBN:
9798368446592
A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues.
Karakan, M. Cagatay.
A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues.
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 200 p.
Source: Dissertations Abstracts International, Volume: 84-07, Section: B.
Thesis (Ph.D.)--Boston University, 2023.
In this dissertation, we first develop a versatile microfluidic heart-on-a-chip model to generate 3D-engineered human cardiac microtissues in highly-controlled microenvironments. The platform, which is enabled by direct laser writing (DLW), has tailor-made attachment sites for cardiac microtissues and comes with integrated strain actuators and force sensors. Application of external pressure waves to the platform results in controllable time-dependent forces on the microtissues. Conversely, oscillatory forces generated by the microtissues are transduced into measurable electrical outputs. After characterization of the responsivity of the transducers, we demonstrate the capabilities of this platform by studying the response of cardiac microtissues to prescribed mechanical loading and pacing. Next, we tune the geometry and mechanical properties of the platform to enable parametric studies on engineered heart tissues. We explore two geometries: a rectangular seeding well with two attachment sites, and a stadium-like seeding well with six attachment sites. The attachment sites are placed symmetrically in the longitudinal direction. The former geometry promotes uniaxial contraction of the tissues; the latter additionally induces diagonal fiber alignment. We systematically increase the length for both configurations and observe a positive correlation between fiber alignment at the center of the microtissues and tissue length. However, progressive thinning and "necking" is also observed, leading to the failure of longer tissues over time. We use the DLW technique to improve the platform, softening the mechanical environment and optimizing the attachment sites for generation of stable microtissues at each length and geometry. Furthermore, electrical pacing is incorporated into the platform to evaluate the functional dynamics of stable microtissues over the entire range of physiological heart rates. Here, we typically observe a decrease in active force and contraction duration as a function of frequency. Lastly, we use a more traditional μTUG platform to demonstrate the effects of subthreshold electrical pacing on the rhythm of the spontaneously contracting cardiac microtissues. Here, we observe periodic M:N patterns, in which there are M cycles of stimulation for every N tissue contractions. Using electric field amplitude, pacing frequency, and homeostatic beating frequencies of the tissues, we provide an empirical map for predicting the emergence of these rhythms.
ISBN: 9798368446592Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Microfluidic heart-on-a-chip
A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues.
LDR
:03639nmm a2200361 4500
001
2401032
005
20241015112500.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798368446592
035
$a
(MiAaPQ)AAI30244820
035
$a
AAI30244820
035
$a
2401032
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Karakan, M. Cagatay.
$0
(orcid)0000-0002-7587-8913
$3
3771093
245
1 2
$a
A Direct-Laser-Written Heart-on-a-Chip Platform for Generation and Stimulation of Engineered Heart Tissues.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
200 p.
500
$a
Source: Dissertations Abstracts International, Volume: 84-07, Section: B.
500
$a
Advisor: Ekinci, Kamil L.
502
$a
Thesis (Ph.D.)--Boston University, 2023.
520
$a
In this dissertation, we first develop a versatile microfluidic heart-on-a-chip model to generate 3D-engineered human cardiac microtissues in highly-controlled microenvironments. The platform, which is enabled by direct laser writing (DLW), has tailor-made attachment sites for cardiac microtissues and comes with integrated strain actuators and force sensors. Application of external pressure waves to the platform results in controllable time-dependent forces on the microtissues. Conversely, oscillatory forces generated by the microtissues are transduced into measurable electrical outputs. After characterization of the responsivity of the transducers, we demonstrate the capabilities of this platform by studying the response of cardiac microtissues to prescribed mechanical loading and pacing. Next, we tune the geometry and mechanical properties of the platform to enable parametric studies on engineered heart tissues. We explore two geometries: a rectangular seeding well with two attachment sites, and a stadium-like seeding well with six attachment sites. The attachment sites are placed symmetrically in the longitudinal direction. The former geometry promotes uniaxial contraction of the tissues; the latter additionally induces diagonal fiber alignment. We systematically increase the length for both configurations and observe a positive correlation between fiber alignment at the center of the microtissues and tissue length. However, progressive thinning and "necking" is also observed, leading to the failure of longer tissues over time. We use the DLW technique to improve the platform, softening the mechanical environment and optimizing the attachment sites for generation of stable microtissues at each length and geometry. Furthermore, electrical pacing is incorporated into the platform to evaluate the functional dynamics of stable microtissues over the entire range of physiological heart rates. Here, we typically observe a decrease in active force and contraction duration as a function of frequency. Lastly, we use a more traditional μTUG platform to demonstrate the effects of subthreshold electrical pacing on the rhythm of the spontaneously contracting cardiac microtissues. Here, we observe periodic M:N patterns, in which there are M cycles of stimulation for every N tissue contractions. Using electric field amplitude, pacing frequency, and homeostatic beating frequencies of the tissues, we provide an empirical map for predicting the emergence of these rhythms.
590
$a
School code: 0017.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Bioengineering.
$3
657580
653
$a
Microfluidic heart-on-a-chip
653
$a
3D-engineered human cardiac microtissues
690
$a
0548
690
$a
0541
690
$a
0202
710
2
$a
Boston University.
$b
Mechanical Engineering ENG.
$3
3181571
773
0
$t
Dissertations Abstracts International
$g
84-07B.
790
$a
0017
791
$a
Ph.D.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30244820
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9509352
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入