語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Wide-Field Mid-Infrared Photothermal...
~
Zong, Haonan,
FindBook
Google Book
Amazon
博客來
Wide-Field Mid-Infrared Photothermal Microscopy /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Wide-Field Mid-Infrared Photothermal Microscopy // Haonan Zong.
作者:
Zong, Haonan,
面頁冊數:
1 electronic resource (182 pages)
附註:
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Contained By:
Dissertations Abstracts International85-07B.
標題:
Optics. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30815954
ISBN:
9798381407365
Wide-Field Mid-Infrared Photothermal Microscopy /
Zong, Haonan,
Wide-Field Mid-Infrared Photothermal Microscopy /
Haonan Zong. - 1 electronic resource (182 pages)
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Infrared (IR) imaging has been a widely used method for chemical imaging of a variety of samples. Traditional infrared imaging method that is directly measuring IR absorption such as Fourier transform infrared (FTIR) microscopy has limited resolution due to the intrinsic long wavelength of the IR beam. Atomic force microscope-infrared (AFM-IR) spectroscopy was developed to break the IR diffraction-limited resolution of FTIR. However, it has limited speed and is only applicable for dry and flat samples. In recent years, mid-infrared photothermal (MIP) microscopy was invented to overcome the limitations of FTIR and AFM-IR. The first developed point-scanning-based MIP achieved sub-micron resolution and depth-resolved IR imaging of live biological samples. Later, wide-field-based MIP schemes were developed and dramatically improved the imaging speed of MIP. In Chapter One, this dissertation introduces the MIP development background and the MIP signal formation mechanism for general samples. In Chapters Two, Three, and Four, this dissertation further developed wide-field MIP and achieved optimal detection of three different specific types of samples by three different methodologies, which are described as follows. (1) Chapter Two, bond-selective interferometric scattering microscopy. (2) Chapter Three, back-ground suppressed high-throughput mid-infrared photothermal microscopy via pupil engineering. (3) Chapter Four, bond-selective full-field optical coherence tomography. In Chapter Five, this dissertation summarizes the work and provides an outlook of future work on video-rate bond-selective intensity diffraction tomography. In the first methodology, we describe a bond-selective interferometric scattering microscope where the mid-IR induced photothermal signal is detected by a visible beam in a wide-field common-path interferometry configuration. Single-particle interferometric reflectance imaging sensor (SP-IRIS) has been a very promising technology for highly sensitive label-free imaging of a broad spectrum of biological nanoparticles from proteins to viruses in a high-throughput manner. Although it can reveal the specimen's size and shape information, the chemical composition is inaccessible in interferometric measurements. IR spectroscopic imaging provides chemical specificity based on inherent chemical bond vibrations of specimens but lacks the ability to image and resolve individual nanoparticles due to long IR wavelengths. Here, a bond-selective interferometric scattering microscope is achieved by detecting the mid-IR-induced photothermal modulation of a visible beam in a wide-field common-path interferometry configuration. A thin film layered substrate is utilized to reduce the reflected light and provide a reference field for the interferometric detection of the weakly scattered field. A pulsed mid-IR laser is employed to modulate the interferometric signal. Subsequent demodulation via a virtual lock-in camera offers simultaneous chemical information about tens of micro- or nano-particles. The chemical contrast arises from a minute change in the particle's scattered field as a consequence of the vibrational absorption at the target molecule. We characterize the system with sub-wavelength polymer beads and highlight biological applications by chemically imaging several microorganisms including Staphylococcus aureus, Escherichia coli, and Candida albicans. A theoretical framework is established to extend bond-selective interferometric scattering microscopy to a broad range of biological micro- and nano-particles.In the second methodology, we demonstrate a back-ground suppressed high-throughput mid-infrared photothermal microscopy via pupil engineering. MIP microscopy has been a promising label-free chemical imaging technique for functional characterization of specimens owing to its enhanced spatial resolution and high specificity. Recently developed wide-field MIP imaging modalities have drastically improved speed and enabled high-throughput imaging of micron-scale subjects. However, the weakly scattered signal from subwavelength particles becomes indistinguishable from the shot-noise as a consequence of the strong background light, leading to limited sensitivity. Here, we demonstrate background-suppressed chemical fingerprinting at a single nanoparticle level by selectively attenuating the reflected light through pupil engineering in the collection path. Our technique provides over 3 orders of magnitude background suppression by quasi-darkfield illumination in the epi-configuration without sacrificing lateral resolution. We demonstrate 6-fold signal-to-background noise ratio improvement, allowing for simultaneous detection and discrimination of hundreds of nanoparticles across a field of view of 70 μm x 70 μm. A comprehensive theoretical framework for photothermal image formation is provided and experimentally validated with 300 and 500 nm PMMA beads. The versatility and utility of our technique are demonstrated via hyperspectral dark-field MIP imaging of S. aureus and E. coli bacteria and MIP imaging of subcellular lipid droplets inside C. albicans and cancer cells.In the third methodology, we present a bond-selective full-field optical coherence tomography. Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Conventional OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bond-selective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 µm PMMA beads embedded in agarose gel. Next, we show 3D hyperspectral imaging of up to 75 µm of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FF-OCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on imaging a highly scattering myelinated axons region in a mouse brain tissue slice.
English
ISBN: 9798381407365Subjects--Topical Terms:
517925
Optics.
Subjects--Index Terms:
Infrared imaging
Wide-Field Mid-Infrared Photothermal Microscopy /
LDR
:07744nmm a22004453i 4500
001
2400519
005
20250522084144.5
006
m o d
007
cr|nu||||||||
008
251215s2024 miu||||||m |||||||eng d
020
$a
9798381407365
035
$a
(MiAaPQD)AAI30815954
035
$a
AAI30815954
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Zong, Haonan,
$e
author.
$0
(orcid)0009-0002-7230-660X
$3
3770548
245
1 0
$a
Wide-Field Mid-Infrared Photothermal Microscopy /
$c
Haonan Zong.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (182 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
500
$a
Advisors: Cheng, Ji-Xin Committee members: Unlu, M. Selim; Tian, Lei; Mertz, Jerome C.; Ramachandran, Siddharth.
502
$b
Ph.D.
$c
Boston University
$d
2024.
520
$a
Infrared (IR) imaging has been a widely used method for chemical imaging of a variety of samples. Traditional infrared imaging method that is directly measuring IR absorption such as Fourier transform infrared (FTIR) microscopy has limited resolution due to the intrinsic long wavelength of the IR beam. Atomic force microscope-infrared (AFM-IR) spectroscopy was developed to break the IR diffraction-limited resolution of FTIR. However, it has limited speed and is only applicable for dry and flat samples. In recent years, mid-infrared photothermal (MIP) microscopy was invented to overcome the limitations of FTIR and AFM-IR. The first developed point-scanning-based MIP achieved sub-micron resolution and depth-resolved IR imaging of live biological samples. Later, wide-field-based MIP schemes were developed and dramatically improved the imaging speed of MIP. In Chapter One, this dissertation introduces the MIP development background and the MIP signal formation mechanism for general samples. In Chapters Two, Three, and Four, this dissertation further developed wide-field MIP and achieved optimal detection of three different specific types of samples by three different methodologies, which are described as follows. (1) Chapter Two, bond-selective interferometric scattering microscopy. (2) Chapter Three, back-ground suppressed high-throughput mid-infrared photothermal microscopy via pupil engineering. (3) Chapter Four, bond-selective full-field optical coherence tomography. In Chapter Five, this dissertation summarizes the work and provides an outlook of future work on video-rate bond-selective intensity diffraction tomography. In the first methodology, we describe a bond-selective interferometric scattering microscope where the mid-IR induced photothermal signal is detected by a visible beam in a wide-field common-path interferometry configuration. Single-particle interferometric reflectance imaging sensor (SP-IRIS) has been a very promising technology for highly sensitive label-free imaging of a broad spectrum of biological nanoparticles from proteins to viruses in a high-throughput manner. Although it can reveal the specimen's size and shape information, the chemical composition is inaccessible in interferometric measurements. IR spectroscopic imaging provides chemical specificity based on inherent chemical bond vibrations of specimens but lacks the ability to image and resolve individual nanoparticles due to long IR wavelengths. Here, a bond-selective interferometric scattering microscope is achieved by detecting the mid-IR-induced photothermal modulation of a visible beam in a wide-field common-path interferometry configuration. A thin film layered substrate is utilized to reduce the reflected light and provide a reference field for the interferometric detection of the weakly scattered field. A pulsed mid-IR laser is employed to modulate the interferometric signal. Subsequent demodulation via a virtual lock-in camera offers simultaneous chemical information about tens of micro- or nano-particles. The chemical contrast arises from a minute change in the particle's scattered field as a consequence of the vibrational absorption at the target molecule. We characterize the system with sub-wavelength polymer beads and highlight biological applications by chemically imaging several microorganisms including Staphylococcus aureus, Escherichia coli, and Candida albicans. A theoretical framework is established to extend bond-selective interferometric scattering microscopy to a broad range of biological micro- and nano-particles.In the second methodology, we demonstrate a back-ground suppressed high-throughput mid-infrared photothermal microscopy via pupil engineering. MIP microscopy has been a promising label-free chemical imaging technique for functional characterization of specimens owing to its enhanced spatial resolution and high specificity. Recently developed wide-field MIP imaging modalities have drastically improved speed and enabled high-throughput imaging of micron-scale subjects. However, the weakly scattered signal from subwavelength particles becomes indistinguishable from the shot-noise as a consequence of the strong background light, leading to limited sensitivity. Here, we demonstrate background-suppressed chemical fingerprinting at a single nanoparticle level by selectively attenuating the reflected light through pupil engineering in the collection path. Our technique provides over 3 orders of magnitude background suppression by quasi-darkfield illumination in the epi-configuration without sacrificing lateral resolution. We demonstrate 6-fold signal-to-background noise ratio improvement, allowing for simultaneous detection and discrimination of hundreds of nanoparticles across a field of view of 70 μm x 70 μm. A comprehensive theoretical framework for photothermal image formation is provided and experimentally validated with 300 and 500 nm PMMA beads. The versatility and utility of our technique are demonstrated via hyperspectral dark-field MIP imaging of S. aureus and E. coli bacteria and MIP imaging of subcellular lipid droplets inside C. albicans and cancer cells.In the third methodology, we present a bond-selective full-field optical coherence tomography. Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Conventional OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bond-selective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 µm PMMA beads embedded in agarose gel. Next, we show 3D hyperspectral imaging of up to 75 µm of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FF-OCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on imaging a highly scattering myelinated axons region in a mouse brain tissue slice.
546
$a
English
590
$a
School code: 0017
650
4
$a
Optics.
$3
517925
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Biophysics.
$3
518360
650
4
$a
Biomedical engineering.
$3
535387
653
$a
Infrared imaging
653
$a
Sub-micron resolution
653
$a
Mid-infrared photothermal microscopy
653
$a
Optical coherence tomography
653
$a
Chemical fingerprinting
690
$a
0752
690
$a
0786
690
$a
0574
690
$a
0541
710
2
$a
Boston University.
$b
Electrical & Computer Engineering ENG.
$e
degree granting institution.
$3
3770549
720
1
$a
Cheng, Ji-Xin
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
85-07B.
790
$a
0017
791
$a
Ph.D.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30815954
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9508839
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入