Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Second Order Effects in Concrete Ins...
~
Al-Rubaye, Salam.
Linked to FindBook
Google Book
Amazon
博客來
Second Order Effects in Concrete Insulated Wall Panels.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Second Order Effects in Concrete Insulated Wall Panels./
Author:
Al-Rubaye, Salam.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2024,
Description:
540 p.
Notes:
Source: Dissertations Abstracts International, Volume: 85-11, Section: A.
Contained By:
Dissertations Abstracts International85-11A.
Subject:
Architectural engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31293193
ISBN:
9798382468587
Second Order Effects in Concrete Insulated Wall Panels.
Al-Rubaye, Salam.
Second Order Effects in Concrete Insulated Wall Panels.
- Ann Arbor : ProQuest Dissertations & Theses, 2024 - 540 p.
Source: Dissertations Abstracts International, Volume: 85-11, Section: A.
Thesis (Ph.D.)--The University of Nebraska - Lincoln, 2024.
Insulated concrete panels (CIPs) have been used for over 60 years for their both structural and thermal resistance. The flexural behavior of CIPs has been investigated in recent years. The CIPs are rapidly becoming ubiquitous in the precast industry, and the tilt-up industry is initiating a study to determine their effectiveness as a tilt-up product. There are several known challenges associated with a tilt-up version of a partially composite wall and likely other unknown challenges. This study was initiated to investigate the behavior of load-bearing concrete insulated wall panels for use in tilt-up construction. The primary objective was to understand the inelastic behavior of these panels so that engineers could perform a proper second-order analysis for combined axial and out-of-plane loading.This dissertation contains information related to the testing of solid and partially composite insulated wall panels that integrated proprietary wythe connection systems. Since tilt-up panel testing of similar scope had not been done since the 1980s on panels of lower height, there were several goals for this testing. This represented an opportunity to validate the current ACI code alternate slender wall analysis method and provide a set of control panels for testing solid tilt-up panel behavior. Testing solid panels and CIPs of 40 ft span, a length typical of contemporary construction, was critical to observe such slenderness ratios and identify significant second-order panel behavior. In addition, 24small-scale panels of 11 ft long were monitored for shrinkage and tested under flexural load to determine the effect of shrinkage and the reinforcement ratio on the cracking moment and tension stiffening model.Using the unique experimental information herein, The Shear Flow method and a new method termed The Shear Slip Method were evaluated to estimate horizontal shear failure. The Shear Flow method, when used properly, results in perhaps an overly conservative prediction of horizontal shear strength but does not match the observed data well. The Shear Slip Method relies on an assumption of the failure slip mechanism (as observed from these and other experiments) and the double shear data to determine a maximum horizontal shear strength while incorporating the ductility of the connectors. This method was found to predict horizontal shear failure both accurately and conservatively.A Modified Slender Wall Method was developed to estimate the contribution of connector slip to the shear deformations in a straightforward way. When using this method to predict the deformations at failure for panels that experienced flexural failure it produced accurate and conservative results. For panels that are controlled by horizontal shear failure, this method can be overly conservative for flexural deformations because it is intentionally simplified. Another method termed the K123 method was demonstrated that can better predict panel deflections and horizontal shear failures using matrix analysis or other methods.The results from the experimental program and the panels from the literature were used to calibrate the OpenSees model. A large parametric study consisted of 648 models using OpenSees to evaluate different lengths of CIPs and connector types that wereoutside of the experimental program scope to demonstrate the effect of the slenderness and axial load. The parametric study confirms that the proposed methods agree well with Opensees models and confirm the findings from the experimental program. This project's findings serve as a foundation for developing a design guide for Tilt-up CIP.
ISBN: 9798382468587Subjects--Topical Terms:
3174102
Architectural engineering.
Subjects--Index Terms:
Sandwich wall panels
Second Order Effects in Concrete Insulated Wall Panels.
LDR
:04750nmm a2200373 4500
001
2399503
005
20240916065501.5
006
m o d
007
cr#unu||||||||
008
251215s2024 ||||||||||||||||| ||eng d
020
$a
9798382468587
035
$a
(MiAaPQ)AAI31293193
035
$a
AAI31293193
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Al-Rubaye, Salam.
$3
3769476
245
1 0
$a
Second Order Effects in Concrete Insulated Wall Panels.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
540 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-11, Section: A.
500
$a
Advisor: Maguire, Marc J.
502
$a
Thesis (Ph.D.)--The University of Nebraska - Lincoln, 2024.
520
$a
Insulated concrete panels (CIPs) have been used for over 60 years for their both structural and thermal resistance. The flexural behavior of CIPs has been investigated in recent years. The CIPs are rapidly becoming ubiquitous in the precast industry, and the tilt-up industry is initiating a study to determine their effectiveness as a tilt-up product. There are several known challenges associated with a tilt-up version of a partially composite wall and likely other unknown challenges. This study was initiated to investigate the behavior of load-bearing concrete insulated wall panels for use in tilt-up construction. The primary objective was to understand the inelastic behavior of these panels so that engineers could perform a proper second-order analysis for combined axial and out-of-plane loading.This dissertation contains information related to the testing of solid and partially composite insulated wall panels that integrated proprietary wythe connection systems. Since tilt-up panel testing of similar scope had not been done since the 1980s on panels of lower height, there were several goals for this testing. This represented an opportunity to validate the current ACI code alternate slender wall analysis method and provide a set of control panels for testing solid tilt-up panel behavior. Testing solid panels and CIPs of 40 ft span, a length typical of contemporary construction, was critical to observe such slenderness ratios and identify significant second-order panel behavior. In addition, 24small-scale panels of 11 ft long were monitored for shrinkage and tested under flexural load to determine the effect of shrinkage and the reinforcement ratio on the cracking moment and tension stiffening model.Using the unique experimental information herein, The Shear Flow method and a new method termed The Shear Slip Method were evaluated to estimate horizontal shear failure. The Shear Flow method, when used properly, results in perhaps an overly conservative prediction of horizontal shear strength but does not match the observed data well. The Shear Slip Method relies on an assumption of the failure slip mechanism (as observed from these and other experiments) and the double shear data to determine a maximum horizontal shear strength while incorporating the ductility of the connectors. This method was found to predict horizontal shear failure both accurately and conservatively.A Modified Slender Wall Method was developed to estimate the contribution of connector slip to the shear deformations in a straightforward way. When using this method to predict the deformations at failure for panels that experienced flexural failure it produced accurate and conservative results. For panels that are controlled by horizontal shear failure, this method can be overly conservative for flexural deformations because it is intentionally simplified. Another method termed the K123 method was demonstrated that can better predict panel deflections and horizontal shear failures using matrix analysis or other methods.The results from the experimental program and the panels from the literature were used to calibrate the OpenSees model. A large parametric study consisted of 648 models using OpenSees to evaluate different lengths of CIPs and connector types that wereoutside of the experimental program scope to demonstrate the effect of the slenderness and axial load. The parametric study confirms that the proposed methods agree well with Opensees models and confirm the findings from the experimental program. This project's findings serve as a foundation for developing a design guide for Tilt-up CIP.
590
$a
School code: 0138.
650
4
$a
Architectural engineering.
$3
3174102
653
$a
Sandwich wall panels
653
$a
Tilt-up construction
653
$a
Wythe Connector
653
$a
Shear Slip Method
690
$a
0543
690
$a
0454
690
$a
0462
710
2
$a
The University of Nebraska - Lincoln.
$b
Engineering.
$3
1036176
773
0
$t
Dissertations Abstracts International
$g
85-11A.
790
$a
0138
791
$a
Ph.D.
792
$a
2024
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31293193
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9507823
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login