語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development and Application of Optic...
~
Ford, Matthew R.
FindBook
Google Book
Amazon
博客來
Development and Application of Optical Coherence Elastography for Corneal Biomechanics.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development and Application of Optical Coherence Elastography for Corneal Biomechanics./
作者:
Ford, Matthew R.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2015,
面頁冊數:
124 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-01, Section: B.
Contained By:
Dissertations Abstracts International82-01B.
標題:
Ophthalmology. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28078450
ISBN:
9798662452930
Development and Application of Optical Coherence Elastography for Corneal Biomechanics.
Ford, Matthew R.
Development and Application of Optical Coherence Elastography for Corneal Biomechanics.
- Ann Arbor : ProQuest Dissertations & Theses, 2015 - 124 p.
Source: Dissertations Abstracts International, Volume: 82-01, Section: B.
Thesis (Ph.D.)--Case Western Reserve University, 2015.
The biomechanical properties of the cornea are an important determinant of both the shape and function of the human visual system. Measuring the biomechanical properties on an in vivo basis requires the development of technologies not typically associated with mechanical measurement. Optical Coherence Elastography (OCE) is an optical based measurement capable of measuring micron level displacements in accessible tissues. The application of OCE to corneal measurement was made possible by the use of speckle tracking in the corneal stroma. Application of OCE to human donor corneas was used to measure the biomechanical properties of the human cornea in three separate states: edematous, normal or deturgessed, and post crosslinking (CXL). The corneal mechanical properties were shown to increase in stiffness in each of the three states, from least stiff when edematous to most stiff post CXL. The early stages of the development of Doppler Shear Wave Optical Coherence Elastography to measure mechanical properties without the need for additional modeling and inferences. The technique utilizes the Doppler shift of a shear wave as it is scanned by OCE to measure the Shear Modulus and Young's modulus of the tissue. As a technique that can be performed on a single two dimensional scan of the tissue, it is suitable for high speed in vivo use. OCE provides a promising tool for measuring the biomechanical properties of the cornea under in vivo conditions.
ISBN: 9798662452930Subjects--Topical Terms:
862704
Ophthalmology.
Subjects--Index Terms:
Optical coherence tomography
Development and Application of Optical Coherence Elastography for Corneal Biomechanics.
LDR
:02696nmm a2200409 4500
001
2398981
005
20240909062208.5
006
m o d
007
cr#unu||||||||
008
251215s2015 ||||||||||||||||| ||eng d
020
$a
9798662452930
035
$a
(MiAaPQ)AAI28078450
035
$a
(MiAaPQ)OhioLINKcase1436545044
035
$a
AAI28078450
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Ford, Matthew R.
$3
3768942
245
1 0
$a
Development and Application of Optical Coherence Elastography for Corneal Biomechanics.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2015
300
$a
124 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-01, Section: B.
500
$a
Advisor: Dupps, William.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2015.
520
$a
The biomechanical properties of the cornea are an important determinant of both the shape and function of the human visual system. Measuring the biomechanical properties on an in vivo basis requires the development of technologies not typically associated with mechanical measurement. Optical Coherence Elastography (OCE) is an optical based measurement capable of measuring micron level displacements in accessible tissues. The application of OCE to corneal measurement was made possible by the use of speckle tracking in the corneal stroma. Application of OCE to human donor corneas was used to measure the biomechanical properties of the human cornea in three separate states: edematous, normal or deturgessed, and post crosslinking (CXL). The corneal mechanical properties were shown to increase in stiffness in each of the three states, from least stiff when edematous to most stiff post CXL. The early stages of the development of Doppler Shear Wave Optical Coherence Elastography to measure mechanical properties without the need for additional modeling and inferences. The technique utilizes the Doppler shift of a shear wave as it is scanned by OCE to measure the Shear Modulus and Young's modulus of the tissue. As a technique that can be performed on a single two dimensional scan of the tissue, it is suitable for high speed in vivo use. OCE provides a promising tool for measuring the biomechanical properties of the cornea under in vivo conditions.
590
$a
School code: 0042.
650
4
$a
Ophthalmology.
$3
862704
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
653
$a
Optical coherence tomography
653
$a
Elastography
653
$a
Cornea
653
$a
Corneal biomechanics
653
$a
Shear wave
690
$a
0381
690
$a
0541
690
$a
0648
690
$a
0574
710
2
$a
Case Western Reserve University.
$b
Biomedical Engineering.
$3
1679892
773
0
$t
Dissertations Abstracts International
$g
82-01B.
790
$a
0042
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28078450
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9507301
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入