語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
What Are Radiologists' Perceptions i...
~
Venturi, Gianni.
FindBook
Google Book
Amazon
博客來
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?/
作者:
Venturi, Gianni.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
194 p.
附註:
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
Contained By:
Dissertations Abstracts International85-03B.
標題:
Computer science. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30723717
ISBN:
9798380182430
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?
Venturi, Gianni.
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 194 p.
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
Thesis (D.H.A.)--Franklin University, 2023.
Deep learning (DL) algorithms are prevalent in radiology as workflow assistants and as modality enhancements. Magnetic resonance imaging (MRI), computerized tomography (CT), diagnostic imaging (DI), ultrasound (US), and positron emission tomography (PET) are modalities that benefit from the DL algorithms and shorter exam times or greater image accuracy. Faster scan time is achieved by the signal to noise ratio (SNR). The distinction is that the technology can enhance images beyond the original resolution from the modality or shorten exam time and rebuild the image quality through SNR algorithms back to approximately the original standard of care (SOC) image. While artificial intelligence signal to noise ratio algorithms (AI-SNR) can enhance an image to a greater accuracy, shorter exam times are a measurable component of a return on investment (ROI) in calculating modality utilization. The algorithm-derived images may have visual variations that are not found on normally acquired original images. The research focused on DL-SNR images on a three-tesla magnetic resonance imaging (3.0T MRI) unit, a high resolution MRI deployment in the industry. The primary research question for this research study is: What are radiologists' perceptions in regard to image quality and increased utilization due to vendor provided DL-SNR on 3.0T MRI? This will be an exploratory qualitative research study using detailed interviews with fellowship-trained radiologists that are using AI-SNR in 3.0T MRI and shortened exam time protocols. Fifteen interviews were conducted. The interview transcriptions were coded using ATLAS.ti to identify common themes and sub-themes in the radiologists' perceptions of DL-SNR imaging. This paper assumes the reader has an adequate understanding of deep learning and radiology processes. The interviews included discussions on key elements on image quality, workflow, reimbursement, legal concerns, and radiologist workload. Issues were identified and potential solutions for optimizations were rendered.
ISBN: 9798380182430Subjects--Topical Terms:
523869
Computer science.
Subjects--Index Terms:
Signal to noise ratio
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?
LDR
:03309nmm a2200373 4500
001
2398544
005
20240812064703.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798380182430
035
$a
(MiAaPQ)AAI30723717
035
$a
(MiAaPQ)OhioLINKfrank1690903539000906
035
$a
AAI30723717
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Venturi, Gianni.
$3
3768459
245
1 0
$a
What Are Radiologists' Perceptions in Regard to Image Quality and Increased Utilization Due to Vendor Provided Deep Learning Signal to Noise Ratio and Deep Learning Reconstruction on 3.0T Magnetic Resonance Imaging?
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
194 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
502
$a
Thesis (D.H.A.)--Franklin University, 2023.
520
$a
Deep learning (DL) algorithms are prevalent in radiology as workflow assistants and as modality enhancements. Magnetic resonance imaging (MRI), computerized tomography (CT), diagnostic imaging (DI), ultrasound (US), and positron emission tomography (PET) are modalities that benefit from the DL algorithms and shorter exam times or greater image accuracy. Faster scan time is achieved by the signal to noise ratio (SNR). The distinction is that the technology can enhance images beyond the original resolution from the modality or shorten exam time and rebuild the image quality through SNR algorithms back to approximately the original standard of care (SOC) image. While artificial intelligence signal to noise ratio algorithms (AI-SNR) can enhance an image to a greater accuracy, shorter exam times are a measurable component of a return on investment (ROI) in calculating modality utilization. The algorithm-derived images may have visual variations that are not found on normally acquired original images. The research focused on DL-SNR images on a three-tesla magnetic resonance imaging (3.0T MRI) unit, a high resolution MRI deployment in the industry. The primary research question for this research study is: What are radiologists' perceptions in regard to image quality and increased utilization due to vendor provided DL-SNR on 3.0T MRI? This will be an exploratory qualitative research study using detailed interviews with fellowship-trained radiologists that are using AI-SNR in 3.0T MRI and shortened exam time protocols. Fifteen interviews were conducted. The interview transcriptions were coded using ATLAS.ti to identify common themes and sub-themes in the radiologists' perceptions of DL-SNR imaging. This paper assumes the reader has an adequate understanding of deep learning and radiology processes. The interviews included discussions on key elements on image quality, workflow, reimbursement, legal concerns, and radiologist workload. Issues were identified and potential solutions for optimizations were rendered.
590
$a
School code: 2055.
650
4
$a
Computer science.
$3
523869
650
4
$a
Medical imaging.
$3
3172799
653
$a
Signal to noise ratio
653
$a
Standard of care image
653
$a
Radiologists
653
$a
Deep learning
690
$a
0984
690
$a
0574
690
$a
0800
710
2
$a
Franklin University.
$b
Health Programs.
$3
3690472
773
0
$t
Dissertations Abstracts International
$g
85-03B.
790
$a
2055
791
$a
D.H.A.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30723717
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9506864
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入