Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Development of Novel Anodized Thin-F...
~
Gagne, Matthew.
Linked to FindBook
Google Book
Amazon
博客來
Development of Novel Anodized Thin-Film Radiation Sensors.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Development of Novel Anodized Thin-Film Radiation Sensors./
Author:
Gagne, Matthew.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2024,
Description:
69 p.
Notes:
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
Contained By:
Dissertations Abstracts International85-08B.
Subject:
Medical imaging. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30695468
ISBN:
9798381447163
Development of Novel Anodized Thin-Film Radiation Sensors.
Gagne, Matthew.
Development of Novel Anodized Thin-Film Radiation Sensors.
- Ann Arbor : ProQuest Dissertations & Theses, 2024 - 69 p.
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
Thesis (Ph.D.)--University of Massachusetts Lowell, 2024.
This item must not be sold to any third party vendors.
Classical radiation detection technology relies on the interaction of radiation within the bulky volume of their sensors. Historically, increasing the sensitivity of a radiation detector required using costly materials, increasing the interaction volume, or including complex and fragile amplification technology. These limitations have meant that only incremental changes and improvements in radiation detection systems have been possible. As radiation use in industry, military applications, and medicine continue to increase, the need for a cost effective, light weight, and resilient radiation detectors is at an all-time high. High Energy Current (HEC) technology relies on surface level radiation interaction with thin and inexpensive materials to produce sensitive radiation sensors. Detection systems using macroscopic fabrication techniques to produce HEC technology have shown the potential for this technology in numerous applications.In order to capitalize on the great advantages of HEC technology over historically available radiation sensors, the technology needs to be miniaturized. This work details the development, fabrication, and testing of a novel thin-film flexible and resilient radiation detector based on HEC principals. Dubbed the Anodox sensor, these prototypes are produced using a novel anodization technique using affordable of the shelf materials. They are capable of reliable radiation detection using commercial electronic reading equipment and can operate in a self-powered or minimal voltage-bias mode. These physically resilient detectors are able to accomplish these goals while having a total thickness of approximately 50 {CE}{ohorn}m.{A0}In this work, Anodox sensors are also tested for their response to electronically produced kVp x-rays. They are first characterized for their response to x-rays from an industrial x-ray tube. Following characterization, they are tested for their response in two modern medical imaging modalities. Fluoroscopy and computer tomography (CT) are two imaging modalities that play an increasingly important role in modern healthcare while also imparting significant radiation dose to patients and clinicians. These proof-of-concept tests show the viability of HEC sensors as an effective dose monitoring tool in modalities where accurate dose measurement is not currently possible. This research highlights the benefits of HEC technology in radiation detection and medicine and shows the need for the further development of this novel technology.Portions of this work were supported by USAF SBIR contract FA8051-17-C-0003.
ISBN: 9798381447163Subjects--Topical Terms:
3172799
Medical imaging.
Subjects--Index Terms:
Anodization technique
Development of Novel Anodized Thin-Film Radiation Sensors.
LDR
:03803nmm a2200397 4500
001
2397411
005
20240624103712.5
006
m o d
007
cr#unu||||||||
008
251215s2024 ||||||||||||||||| ||eng d
020
$a
9798381447163
035
$a
(MiAaPQ)AAI30695468
035
$a
AAI30695468
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Gagne, Matthew.
$3
3437889
245
1 0
$a
Development of Novel Anodized Thin-Film Radiation Sensors.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
69 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-08, Section: B.
500
$a
Advisor: Sajo, Erno;Ngwa, Wilfred.
502
$a
Thesis (Ph.D.)--University of Massachusetts Lowell, 2024.
506
$a
This item must not be sold to any third party vendors.
520
$a
Classical radiation detection technology relies on the interaction of radiation within the bulky volume of their sensors. Historically, increasing the sensitivity of a radiation detector required using costly materials, increasing the interaction volume, or including complex and fragile amplification technology. These limitations have meant that only incremental changes and improvements in radiation detection systems have been possible. As radiation use in industry, military applications, and medicine continue to increase, the need for a cost effective, light weight, and resilient radiation detectors is at an all-time high. High Energy Current (HEC) technology relies on surface level radiation interaction with thin and inexpensive materials to produce sensitive radiation sensors. Detection systems using macroscopic fabrication techniques to produce HEC technology have shown the potential for this technology in numerous applications.In order to capitalize on the great advantages of HEC technology over historically available radiation sensors, the technology needs to be miniaturized. This work details the development, fabrication, and testing of a novel thin-film flexible and resilient radiation detector based on HEC principals. Dubbed the Anodox sensor, these prototypes are produced using a novel anodization technique using affordable of the shelf materials. They are capable of reliable radiation detection using commercial electronic reading equipment and can operate in a self-powered or minimal voltage-bias mode. These physically resilient detectors are able to accomplish these goals while having a total thickness of approximately 50 {CE}{ohorn}m.{A0}In this work, Anodox sensors are also tested for their response to electronically produced kVp x-rays. They are first characterized for their response to x-rays from an industrial x-ray tube. Following characterization, they are tested for their response in two modern medical imaging modalities. Fluoroscopy and computer tomography (CT) are two imaging modalities that play an increasingly important role in modern healthcare while also imparting significant radiation dose to patients and clinicians. These proof-of-concept tests show the viability of HEC sensors as an effective dose monitoring tool in modalities where accurate dose measurement is not currently possible. This research highlights the benefits of HEC technology in radiation detection and medicine and shows the need for the further development of this novel technology.Portions of this work were supported by USAF SBIR contract FA8051-17-C-0003.
590
$a
School code: 0111.
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Nanotechnology.
$3
526235
653
$a
Anodization technique
653
$a
Dosimetry
653
$a
Nano-fabrication
653
$a
Radiation
653
$a
Thin-film
690
$a
0574
690
$a
0541
690
$a
0652
710
2
$a
University of Massachusetts Lowell.
$b
Biomedical Engineering.
$3
3435996
773
0
$t
Dissertations Abstracts International
$g
85-08B.
790
$a
0111
791
$a
Ph.D.
792
$a
2024
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30695468
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9505731
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login