語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Computational Compensation for Model...
~
Hu, Peng,
FindBook
Google Book
Amazon
博客來
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography // Peng Hu.
作者:
Hu, Peng,
面頁冊數:
1 electronic resource (154 pages)
附註:
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
Contained By:
Dissertations Abstracts International85-03B.
標題:
Tomography. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30604316
ISBN:
9798380274746
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography /
Hu, Peng,
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography /
Peng Hu. - 1 electronic resource (154 pages)
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
Photoacoustic computed tomography (PACT) images biological tissues' optical absorption through detection of photon-absorption-induced ultrasonic waves. Various systems have been proposed for PACT and they are described by different mathematical models to reconstruct from detected ultrasonic signals the photon-absorption-induced initial pressure, the main contrast in PACT. Accurate image reconstruction has high requirements for the system and the mathematical model, which is often imperfect in practice due to multiple factors, e.g., limited transducer bandwidth, finite transducer element size, sparse spatial sampling, partial-view detection, and tissue motion. The focus of this dissertation is on using computational methods to compensate for these model imperfections.First, for a human breast imaging system based on a full-ring transducer array, we incorporate the limited transducer bandwidth into the model for spatiotemporal analysis to clarify the aliasing due to sparse spatial sampling and propose (1) two methods (radius-dependent spatiotemporal antialiasing and location-dependent spatiotemporal antialiasing) to mitigate these artifacts. Second, for an isotropic-resolution 3D PACT system formed by four arc arrays, we consider both the limited transducer bandwidth and the finite transducer element size and (2) compress the system matrix through singular value decomposition and fast Fourier transform for its efficient explicit expression. Enabled by this expression, we then propose (3) fast sparsely sampling functional imaging by incorporating a densely sampled prior image into the system matrix, which maintains the critical linearity while mitigating artifacts, and (4) intra-image nonrigid motion correction by incorporating the motion as subdomain translations into the system matrix and reconstructing the translations together with the image iteratively. Finally, for a single-shot 3D PACT system based on a single ultrasonic transducer, we propose (5) a fast implementation of the forward model by connecting traditional PACT with virtual detector responses through fast Fourier transform, and we iteratively reconstruct the image from signals with extremely compressed sensing and partial-view detection.All these proposed methods enable image reconstruction or significantly improve image quality in numerical simulations, phantom experiments, and in vivoexperiments. Although they are demonstrated only for certain PACT systems, they are directly applicable to other systems and can be extended to other tomographic imaging modalities such as X-ray computed tomography (X-ray CT) and magnetic resonance imaging (MRI).
English
ISBN: 9798380274746Subjects--Topical Terms:
836553
Tomography.
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography /
LDR
:04023nmm a22003973i 4500
001
2396192
005
20250522083207.5
006
m o d
007
cr|nu||||||||
008
251215s2023 miu||||||m |||||||eng d
020
$a
9798380274746
035
$a
(MiAaPQD)AAI30604316
035
$a
(MiAaPQD)Caltech_oaithesislibrarycaltechedu15277
035
$a
AAI30604316
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Hu, Peng,
$e
author.
$3
3765817
245
1 0
$a
Computational Compensation for Model Imperfections in Photoacoustic Computed Tomography /
$c
Peng Hu.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
1 electronic resource (154 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 85-03, Section: B.
500
$a
Advisors: Wang, Lihong Committee members: Bouman, Katherine L.; Colonius, Timothy E.
502
$b
Ph.D.
$c
California Institute of Technology
$d
2023.
520
$a
Photoacoustic computed tomography (PACT) images biological tissues' optical absorption through detection of photon-absorption-induced ultrasonic waves. Various systems have been proposed for PACT and they are described by different mathematical models to reconstruct from detected ultrasonic signals the photon-absorption-induced initial pressure, the main contrast in PACT. Accurate image reconstruction has high requirements for the system and the mathematical model, which is often imperfect in practice due to multiple factors, e.g., limited transducer bandwidth, finite transducer element size, sparse spatial sampling, partial-view detection, and tissue motion. The focus of this dissertation is on using computational methods to compensate for these model imperfections.First, for a human breast imaging system based on a full-ring transducer array, we incorporate the limited transducer bandwidth into the model for spatiotemporal analysis to clarify the aliasing due to sparse spatial sampling and propose (1) two methods (radius-dependent spatiotemporal antialiasing and location-dependent spatiotemporal antialiasing) to mitigate these artifacts. Second, for an isotropic-resolution 3D PACT system formed by four arc arrays, we consider both the limited transducer bandwidth and the finite transducer element size and (2) compress the system matrix through singular value decomposition and fast Fourier transform for its efficient explicit expression. Enabled by this expression, we then propose (3) fast sparsely sampling functional imaging by incorporating a densely sampled prior image into the system matrix, which maintains the critical linearity while mitigating artifacts, and (4) intra-image nonrigid motion correction by incorporating the motion as subdomain translations into the system matrix and reconstructing the translations together with the image iteratively. Finally, for a single-shot 3D PACT system based on a single ultrasonic transducer, we propose (5) a fast implementation of the forward model by connecting traditional PACT with virtual detector responses through fast Fourier transform, and we iteratively reconstruct the image from signals with extremely compressed sensing and partial-view detection.All these proposed methods enable image reconstruction or significantly improve image quality in numerical simulations, phantom experiments, and in vivoexperiments. Although they are demonstrated only for certain PACT systems, they are directly applicable to other systems and can be extended to other tomographic imaging modalities such as X-ray computed tomography (X-ray CT) and magnetic resonance imaging (MRI).
546
$a
English
590
$a
School code: 0037
650
4
$a
Tomography.
$3
836553
650
4
$a
Blood vessels.
$3
3561732
650
4
$a
Fourier transforms.
$3
3545926
650
4
$a
Ultrasonic transducers.
$3
518836
650
4
$a
Iterative methods.
$3
3686120
650
4
$a
Hemodynamics.
$3
695992
650
4
$a
Pressure distribution.
$3
3564852
650
4
$a
Boxes.
$3
3564918
650
4
$a
Tissues.
$3
608294
650
4
$a
Data acquisition systems.
$3
3696622
650
4
$a
Information science.
$3
554358
650
4
$a
Mathematics.
$3
515831
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Physiology.
$3
518431
690
$a
0723
690
$a
0405
690
$a
0574
690
$a
0719
710
2
$a
California Institute of Technology.
$b
Engineering and Applied Science.
$e
degree granting institution.
$3
3765818
720
1
$a
Wang, Lihong
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
85-03B.
790
$a
0037
791
$a
Ph.D.
792
$a
2023
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30604316
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9504512
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入