Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions./
作者:
Treb, Kevin.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
142 p.
附註:
Source: Dissertations Abstracts International, Volume: 84-12, Section: B.
Contained By:
Dissertations Abstracts International84-12B.
標題:
Medical imaging. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30524796
ISBN:
9798379615390
Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions.
Treb, Kevin.
Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions.
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 142 p.
Source: Dissertations Abstracts International, Volume: 84-12, Section: B.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2023.
This item must not be sold to any third party vendors.
C-arm x-ray systems equipped with energy integrating detectors (EIDs) are the primary workhorses for endovascular and percutaneous image-guided interventions (IGIs) and are capable of both real-time planar imaging as well as cone-beam CT. Despite its clinical success, technical limitations of the EID limit the achievable image-quality from C-arms for low-contrast or ultra-high-resolution (UHR) imaging tasks. In addition, commercial C-arm systems are not capable of spectral imaging, for example, to discriminate between different materials such as iodine and calcium. These limitations are in part due to the energy integration mechanism, where the x-ray-induced signal in the detector is integrated over an entire image frame, and thus energy information for each x-ray interaction is lost; additionally, the unwanted influence of electronic noise contributes to this integrated signal and can result in increased noise in the final image. The indirect conversion scintillator sensor that most FPDs are equipped with also limits the achievable spatial resolution and has undesirable lag properties that can negatively impact image quality. In comparison to EIDs, photon counting detectors (PCDs) process each x-ray photon interaction individually, and thus can introduce spectral capabilities by measuring the charge induced by each photon interaction; this same energy thresholding mechanism enables the influence of electronic noise on the photon counts measurement to be removed. PCDs also have negligible lag effects due to the necessity for fast signal processing to count individual photons, which in practice is accomplished in medical x-ray imaging by using direct conversion semiconductor sensors. Semiconductor-based PCDs also have the potential for UHR imaging by reducing the spatial spreading of information carriers in the sensor compared to scintillators. To introduce the benefits of PCDs to the interventional suite for IGIs, this thesis work presents the development of a prototype photon counting C-arm system with a semiconductor-based PCD mounted onto a clinical C-arm gantry and the utilization of a narrow-beam geometry to reduce scatter and cone beam artifacts. Initial phantom and in vivo imaging studies demonstrate the potential non-spectral image-quality benefits for low-contrast CT imaging tasks, as well as added spectral imaging utility offered by the PCD. To compensate for the reduced field of view along the longitudinal direction from the use of a narrow-beam geometry, multi-sweep scan protocols were used to extend the volumetric coverage of the PCD C-arm prototype; UHR capabilities were also developed to take advantage of the properties of the semiconductor-based PCD. Additionally, proof of concept experiments were performed to validate a novel detector design that combines a smaller central PCD with the surrounding EID to facilitate the translation of PCD C-arm technology into clinical use without introducing operation or workflow issues. Lastly, a method to utilize total induced charge in a PCD to correct for photon count loss and spectral distortions caused by pulse pile-up was developed and validated.
ISBN: 9798379615390Subjects--Topical Terms:
3172799
Medical imaging.
Subjects--Index Terms:
C-arm imaging systems
Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions.
LDR
:04428nmm a2200397 4500
001
2393059
005
20231130111628.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798379615390
035
$a
(MiAaPQ)AAI30524796
035
$a
AAI30524796
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Treb, Kevin.
$3
3762501
245
1 0
$a
Development of a Photon Counting C-Arm Prototype System for Image-Guided Interventions.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
142 p.
500
$a
Source: Dissertations Abstracts International, Volume: 84-12, Section: B.
500
$a
Advisor: Li, Ke.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2023.
506
$a
This item must not be sold to any third party vendors.
520
$a
C-arm x-ray systems equipped with energy integrating detectors (EIDs) are the primary workhorses for endovascular and percutaneous image-guided interventions (IGIs) and are capable of both real-time planar imaging as well as cone-beam CT. Despite its clinical success, technical limitations of the EID limit the achievable image-quality from C-arms for low-contrast or ultra-high-resolution (UHR) imaging tasks. In addition, commercial C-arm systems are not capable of spectral imaging, for example, to discriminate between different materials such as iodine and calcium. These limitations are in part due to the energy integration mechanism, where the x-ray-induced signal in the detector is integrated over an entire image frame, and thus energy information for each x-ray interaction is lost; additionally, the unwanted influence of electronic noise contributes to this integrated signal and can result in increased noise in the final image. The indirect conversion scintillator sensor that most FPDs are equipped with also limits the achievable spatial resolution and has undesirable lag properties that can negatively impact image quality. In comparison to EIDs, photon counting detectors (PCDs) process each x-ray photon interaction individually, and thus can introduce spectral capabilities by measuring the charge induced by each photon interaction; this same energy thresholding mechanism enables the influence of electronic noise on the photon counts measurement to be removed. PCDs also have negligible lag effects due to the necessity for fast signal processing to count individual photons, which in practice is accomplished in medical x-ray imaging by using direct conversion semiconductor sensors. Semiconductor-based PCDs also have the potential for UHR imaging by reducing the spatial spreading of information carriers in the sensor compared to scintillators. To introduce the benefits of PCDs to the interventional suite for IGIs, this thesis work presents the development of a prototype photon counting C-arm system with a semiconductor-based PCD mounted onto a clinical C-arm gantry and the utilization of a narrow-beam geometry to reduce scatter and cone beam artifacts. Initial phantom and in vivo imaging studies demonstrate the potential non-spectral image-quality benefits for low-contrast CT imaging tasks, as well as added spectral imaging utility offered by the PCD. To compensate for the reduced field of view along the longitudinal direction from the use of a narrow-beam geometry, multi-sweep scan protocols were used to extend the volumetric coverage of the PCD C-arm prototype; UHR capabilities were also developed to take advantage of the properties of the semiconductor-based PCD. Additionally, proof of concept experiments were performed to validate a novel detector design that combines a smaller central PCD with the surrounding EID to facilitate the translation of PCD C-arm technology into clinical use without introducing operation or workflow issues. Lastly, a method to utilize total induced charge in a PCD to correct for photon count loss and spectral distortions caused by pulse pile-up was developed and validated.
590
$a
School code: 0262.
650
4
$a
Medical imaging.
$3
3172799
653
$a
C-arm imaging systems
653
$a
Cone-beam CT
653
$a
Fluoroscopy
653
$a
Image-guided interventions
653
$a
Photon counting detectors
653
$a
Pulse pile-up
653
$a
Radiology
690
$a
0574
710
2
$a
The University of Wisconsin - Madison.
$b
Medical Physics.
$3
2097834
773
0
$t
Dissertations Abstracts International
$g
84-12B.
790
$a
0262
791
$a
Ph.D.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30524796
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9501379
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入