語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK : = Analysis of the Impact of In-Use.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK :/
其他題名:
Analysis of the Impact of In-Use.
作者:
Bacon, Matthew.
面頁冊數:
1 online resource (508 pages)
附註:
Source: Dissertations Abstracts International, Volume: 83-03, Section: B.
Contained By:
Dissertations Abstracts International83-03B.
標題:
Design. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28801536click for full text (PQDT)
ISBN:
9798538134748
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK : = Analysis of the Impact of In-Use.
Bacon, Matthew.
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK :
Analysis of the Impact of In-Use. - 1 online resource (508 pages)
Source: Dissertations Abstracts International, Volume: 83-03, Section: B.
Thesis (Ph.D.)--University of Salford (United Kingdom), 2015.
Includes bibliographical references
This thesis introduces an innovative contribution to the low energy - low carbon design of acute hospitals in the UK. The need for innovation in acute hospital design arises from the consistently poor energy and carbon performance of the health care estate over a period of nearly three decades. This poor performance translates into a situation where overall consumption of energy in the health care estate has remained largely unchanged over that period, despite substantive improvements in the asset specifications of these facilities. With respect to the commitment made by the British Government to reduce carbon emissions under the Climate Change Act (2008) this situation is clearly unacceptable, because that commitment requires an 80% reduction in carbon emissions by 2050. Of equal concern has been the poor predictability of energy forecasts for new buildings, where the apparent difference in performance between design and what is actually achieved In-use can be substantial.In terms of energy consumption and the associated carbon emissions, the author's research has discovered that the issues of poor In-Use performance and poor predictability of performance in acute hospitals are directly linked. The central causal factor that leads to both is a poor understanding of clinical user practices and the impact of those practices on the design and engineering of the hospital. The research identified that without such an understanding it means that hospital planners, designers and engineers are required to make substantial assumptions concerning In-Use during the design process, most notably concerning occupancy presence and the diversity of occupancy.The author's investigations found that it would be possible to use simulation to replicate how acute hospitals operate by utilising clinical process information contained in operational policy documents. It was also discovered that the data derived from clinical information systems could be used to run the simulation. It is the unique methods developed by the author that are his contribution to new knowledge. One method developed by the author is called Occupancy Analytics. The method enables the author to predict occupancy presence and diversity within a range of probabilities at any hour of the day within the hospital. A second method enables these values to be modelled within another simulation called the Whole Facility Energy Model. Using both models in sequence the author discovered how to directly correlate the impacts of operational policies and working practices to energy consumption and the associated carbon emissions.Using this new knowledge, the factors that determine occupancy presence and diversity were then investigated. The author reasoned that if these could be managed then it would be possible to optimise the engineering design, and the consequential energy consumption and the associated carbon emissions. Through the use of a case study that is both revelatory and longitudinal (Yin, Op Cit) the author demonstrates how this objective was achieved.Finally, using the results from both Occupancy Analytics and Whole Facility Energy Modelling the author also discovered that it would be possible to establish norms for energy and carbon performance based on each patient type using the clinical services of the acute hospital. In the case study, the author demonstrates how this form of analysis could be used to establish the basis for departmental energy budgets, which he envisages could make an important contribution to the future optimisation of low energy - low carbon performance of acute hospitals in the UK.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798538134748Subjects--Topical Terms:
518875
Design.
Subjects--Index Terms:
Carbon emissionsIndex Terms--Genre/Form:
542853
Electronic books.
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK : = Analysis of the Impact of In-Use.
LDR
:05068nmm a2200409K 4500
001
2360638
005
20231015184441.5
006
m o d
007
cr mn ---uuuuu
008
241011s2015 xx obm 000 0 eng d
020
$a
9798538134748
035
$a
(MiAaPQ)AAI28801536
035
$a
AAI28801536
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Bacon, Matthew.
$3
3701261
245
1 0
$a
Low Energy - Low Carbon Acute Hospital Engineering Design and Operation in the UK :
$b
Analysis of the Impact of In-Use.
264
0
$c
2015
300
$a
1 online resource (508 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 83-03, Section: B.
502
$a
Thesis (Ph.D.)--University of Salford (United Kingdom), 2015.
504
$a
Includes bibliographical references
520
$a
This thesis introduces an innovative contribution to the low energy - low carbon design of acute hospitals in the UK. The need for innovation in acute hospital design arises from the consistently poor energy and carbon performance of the health care estate over a period of nearly three decades. This poor performance translates into a situation where overall consumption of energy in the health care estate has remained largely unchanged over that period, despite substantive improvements in the asset specifications of these facilities. With respect to the commitment made by the British Government to reduce carbon emissions under the Climate Change Act (2008) this situation is clearly unacceptable, because that commitment requires an 80% reduction in carbon emissions by 2050. Of equal concern has been the poor predictability of energy forecasts for new buildings, where the apparent difference in performance between design and what is actually achieved In-use can be substantial.In terms of energy consumption and the associated carbon emissions, the author's research has discovered that the issues of poor In-Use performance and poor predictability of performance in acute hospitals are directly linked. The central causal factor that leads to both is a poor understanding of clinical user practices and the impact of those practices on the design and engineering of the hospital. The research identified that without such an understanding it means that hospital planners, designers and engineers are required to make substantial assumptions concerning In-Use during the design process, most notably concerning occupancy presence and the diversity of occupancy.The author's investigations found that it would be possible to use simulation to replicate how acute hospitals operate by utilising clinical process information contained in operational policy documents. It was also discovered that the data derived from clinical information systems could be used to run the simulation. It is the unique methods developed by the author that are his contribution to new knowledge. One method developed by the author is called Occupancy Analytics. The method enables the author to predict occupancy presence and diversity within a range of probabilities at any hour of the day within the hospital. A second method enables these values to be modelled within another simulation called the Whole Facility Energy Model. Using both models in sequence the author discovered how to directly correlate the impacts of operational policies and working practices to energy consumption and the associated carbon emissions.Using this new knowledge, the factors that determine occupancy presence and diversity were then investigated. The author reasoned that if these could be managed then it would be possible to optimise the engineering design, and the consequential energy consumption and the associated carbon emissions. Through the use of a case study that is both revelatory and longitudinal (Yin, Op Cit) the author demonstrates how this objective was achieved.Finally, using the results from both Occupancy Analytics and Whole Facility Energy Modelling the author also discovered that it would be possible to establish norms for energy and carbon performance based on each patient type using the clinical services of the acute hospital. In the case study, the author demonstrates how this form of analysis could be used to establish the basis for departmental energy budgets, which he envisages could make an important contribution to the future optimisation of low energy - low carbon performance of acute hospitals in the UK.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Design.
$3
518875
650
4
$a
Energy.
$3
876794
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Science.
$3
516376
650
4
$a
Writing.
$3
551664
650
4
$a
Ontology.
$3
530874
650
4
$a
Emissions.
$3
3559499
650
4
$a
Design engineering.
$3
3681662
650
4
$a
Green buildings.
$3
3559500
650
4
$a
Objectives.
$3
3561496
650
4
$a
Climate change.
$2
bicssc
$3
2079509
650
4
$a
Building construction.
$3
2071835
650
4
$a
Engineers.
$3
681868
650
4
$a
Case studies.
$2
itrt
$3
996239
650
4
$a
Innovations.
$3
754112
650
4
$a
Simulation.
$3
644748
650
4
$a
Research methodology.
$3
3559994
650
4
$a
Physics.
$3
516296
650
4
$a
Experiments.
$3
525909
650
4
$a
Planning.
$3
552734
650
4
$a
Carbon.
$3
604057
650
4
$a
Knowledge.
$3
872758
650
4
$a
Medical research.
$2
bicssc
$3
1556686
650
4
$a
Departments.
$3
3683760
653
$a
Carbon emissions
653
$a
Energy consumption
653
$a
Carbon performance
653
$a
Energy budgets
653
$a
Design of acute hospitals
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0389
690
$a
0544
690
$a
0791
690
$a
0404
690
$a
0605
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Salford (United Kingdom).
$3
3556058
773
0
$t
Dissertations Abstracts International
$g
83-03B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28801536
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9482994
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入