語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI).
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI)./
作者:
Schuurmans, Tyler J.
面頁冊數:
1 online resource (86 pages)
附註:
Source: Masters Abstracts International, Volume: 79-07.
Contained By:
Masters Abstracts International79-07.
標題:
Dentistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10621699click for full text (PQDT)
ISBN:
9780355403794
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI).
Schuurmans, Tyler J.
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI).
- 1 online resource (86 pages)
Source: Masters Abstracts International, Volume: 79-07.
Thesis (M.S.)--University of Minnesota, 2017.
Includes bibliographical references
Introduction: Magnetic Resonance Imaging (MRI) has the potential to aid in determining the presence and extent of cracks/fractures in teeth due to more advantageous contrast, without ionizing radiation. An MRI technique called Sweep Imaging with Fourier Transform (SWIFT) has overcome many of the inherent difficulties of conventional MRI with detecting fast-relaxing signals from densely mineralized dental tissues. The objectives of this in vitro investigation were to develop MRI criteria for root crack/fracture identification in teeth and to establish intra- and inter-rater reliabilities and corresponding sensitivity and specificity values for the detection of tooth-root cracks/fractures in SWIFT MRI and limited field of view (FOV) CBCT. Materials and Methods: MRI-based criteria for crack/fracture appearance was developed by an MRI physicist and 6 dentists, including 3 endodontists and 1 Oral and Maxillofacial (OMF) radiologist. Twenty-nine human adult teeth previously extracted following clinical diagnosis by a board-certified endodontist of a root crack/fracture were frequency-matched to 29 non-cracked controls. Crack/fracture status confirmation was performed with magnified visual inspection, transillumination and vital staining. Samples were scanned with two 3D imaging modalities: 1) SWIFT MRI (10 teeth/scan) via a custom oral radiofrequency (RF) coil and a 90cm, 4-T magnet; 2) Limited FOV CBCT (1 tooth/scan) via a Carestream (CS) 9000 (Rochester, NY). Following a training period, a blinded 4-member panel (3 endodontists, 1 OMF radiologist) evaluated the images with a proportion randomly re-tested to establish intra-rater reliability. Overall observer agreement was measured using Cohen's kappa and levels of agreement judged using the criteria of Landis and Koch. Sensitivity and specificity were computed with 95% confidence interval (CI); statistical significance was set at α ≤ 0.05. Results: MRI-based crack/fracture criteria were defined as 1-2 sharply-delineated, high-signal (bright/white) line shape(s) that must be visible on multiple contiguous image slices. The line shape(s) must present as: single entities, or parallel pairs in close proximity, or pairs in close proximity exhibiting convergence or divergence extending from the external boundary of the tooth to the pulpal cavity. Intra-rater reliability for MRI was fair-to-almost perfect (κ = 0.38-1.00) and for CBCT was moderate-to-almost perfect (κ = 0.66-1.00). Inter-rater reliability for MRI was fair (κ = 0.21; 95% CI: 0.10-0.31; p < 0.001) and for CBCT was moderate (κ = 0.45; 95% CI: 0.34-0.56; p < 0.001). Sensitivity: MRI = 0.59 (95% CI: 0.39-0.76; p = 0.46); CBCT = 0.59 (95% CI: 0.59-0.76; p = 0.46). Specificity: MRI = 0.83 (95% CI: 0.64-0.94; p < 0.01); CBCT = 0.90 (95% CI: 0.73-0.98; p < 0.01). Conclusions: Education and training for both imaging modalities is needed to improve reliabilities for the identification of tooth-root crack/fractures. Despite the advantages of increased contrast and absence of artifact from radio-dense materials in MRI, comparable measures of sensitivity and specificity (in relation to CBCT) suggest quality MRI improvements are needed, specifically in image acquisition and post-processing parameters. Given the early stage of technology development and multiple available pathways to optimize MR imaging of teeth, there may be a use for SWIFT MRI in detecting cracks and fractures in teeth.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9780355403794Subjects--Topical Terms:
828971
Dentistry.
Subjects--Index Terms:
AccuracyIndex Terms--Genre/Form:
542853
Electronic books.
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI).
LDR
:04958nmm a2200433K 4500
001
2360610
005
20231009073456.5
006
m o d
007
cr mn ---uuuuu
008
241011s2017 xx obm 000 0 eng d
020
$a
9780355403794
035
$a
(MiAaPQ)AAI10621699
035
$a
(MiAaPQ)umn:18494
035
$a
AAI10621699
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Schuurmans, Tyler J.
$3
3701232
245
1 0
$a
Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI).
264
0
$c
2017
300
$a
1 online resource (86 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 79-07.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: McClanahan, Scott B.
502
$a
Thesis (M.S.)--University of Minnesota, 2017.
504
$a
Includes bibliographical references
520
$a
Introduction: Magnetic Resonance Imaging (MRI) has the potential to aid in determining the presence and extent of cracks/fractures in teeth due to more advantageous contrast, without ionizing radiation. An MRI technique called Sweep Imaging with Fourier Transform (SWIFT) has overcome many of the inherent difficulties of conventional MRI with detecting fast-relaxing signals from densely mineralized dental tissues. The objectives of this in vitro investigation were to develop MRI criteria for root crack/fracture identification in teeth and to establish intra- and inter-rater reliabilities and corresponding sensitivity and specificity values for the detection of tooth-root cracks/fractures in SWIFT MRI and limited field of view (FOV) CBCT. Materials and Methods: MRI-based criteria for crack/fracture appearance was developed by an MRI physicist and 6 dentists, including 3 endodontists and 1 Oral and Maxillofacial (OMF) radiologist. Twenty-nine human adult teeth previously extracted following clinical diagnosis by a board-certified endodontist of a root crack/fracture were frequency-matched to 29 non-cracked controls. Crack/fracture status confirmation was performed with magnified visual inspection, transillumination and vital staining. Samples were scanned with two 3D imaging modalities: 1) SWIFT MRI (10 teeth/scan) via a custom oral radiofrequency (RF) coil and a 90cm, 4-T magnet; 2) Limited FOV CBCT (1 tooth/scan) via a Carestream (CS) 9000 (Rochester, NY). Following a training period, a blinded 4-member panel (3 endodontists, 1 OMF radiologist) evaluated the images with a proportion randomly re-tested to establish intra-rater reliability. Overall observer agreement was measured using Cohen's kappa and levels of agreement judged using the criteria of Landis and Koch. Sensitivity and specificity were computed with 95% confidence interval (CI); statistical significance was set at α ≤ 0.05. Results: MRI-based crack/fracture criteria were defined as 1-2 sharply-delineated, high-signal (bright/white) line shape(s) that must be visible on multiple contiguous image slices. The line shape(s) must present as: single entities, or parallel pairs in close proximity, or pairs in close proximity exhibiting convergence or divergence extending from the external boundary of the tooth to the pulpal cavity. Intra-rater reliability for MRI was fair-to-almost perfect (κ = 0.38-1.00) and for CBCT was moderate-to-almost perfect (κ = 0.66-1.00). Inter-rater reliability for MRI was fair (κ = 0.21; 95% CI: 0.10-0.31; p < 0.001) and for CBCT was moderate (κ = 0.45; 95% CI: 0.34-0.56; p < 0.001). Sensitivity: MRI = 0.59 (95% CI: 0.39-0.76; p = 0.46); CBCT = 0.59 (95% CI: 0.59-0.76; p = 0.46). Specificity: MRI = 0.83 (95% CI: 0.64-0.94; p < 0.01); CBCT = 0.90 (95% CI: 0.73-0.98; p < 0.01). Conclusions: Education and training for both imaging modalities is needed to improve reliabilities for the identification of tooth-root crack/fractures. Despite the advantages of increased contrast and absence of artifact from radio-dense materials in MRI, comparable measures of sensitivity and specificity (in relation to CBCT) suggest quality MRI improvements are needed, specifically in image acquisition and post-processing parameters. Given the early stage of technology development and multiple available pathways to optimize MR imaging of teeth, there may be a use for SWIFT MRI in detecting cracks and fractures in teeth.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Dentistry.
$3
828971
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Nuclear physics.
$3
517741
653
$a
Accuracy
653
$a
Crack
653
$a
Fracture
653
$a
MRI
653
$a
SWIFT MRI
653
$a
Teeth
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0567
690
$a
0574
690
$a
0756
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Minnesota.
$b
Dentistry.
$3
3434199
773
0
$t
Masters Abstracts International
$g
79-07.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10621699
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9482966
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入