語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging./
作者:
Mariappan, Leo.
面頁冊數:
1 online resource (150 pages)
附註:
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
Contained By:
Dissertations Abstracts International76-05B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3643645click for full text (PQDT)
ISBN:
9781321314175
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
Mariappan, Leo.
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
- 1 online resource (150 pages)
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
Thesis (Ph.D.)--University of Minnesota, 2014.
Includes bibliographical references
Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9781321314175Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Electrical impedanceIndex Terms--Genre/Form:
542853
Electronic books.
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
LDR
:04005nmm a2200397K 4500
001
2360593
005
20230928115721.5
006
m o d
007
cr mn ---uuuuu
008
241011s2014 xx obm 000 0 eng d
020
$a
9781321314175
035
$a
(MiAaPQ)AAI3643645
035
$a
(MiAaPQ)umn:15340
035
$a
AAI3643645
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Mariappan, Leo.
$3
3701215
245
1 0
$a
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
264
0
$c
2014
300
$a
1 online resource (150 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: He, Bin.
502
$a
Thesis (Ph.D.)--University of Minnesota, 2014.
504
$a
Includes bibliographical references
520
$a
Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Acoustics.
$3
879105
653
$a
Electrical impedance
653
$a
Magneto acoustic
653
$a
Ultrasound tomography
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0541
690
$a
0574
690
$a
0986
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Minnesota.
$b
Biomedical Engineering.
$3
1669049
773
0
$t
Dissertations Abstracts International
$g
76-05B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3643645
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9482949
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入