Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Linked to FindBook
Google Book
Amazon
博客來
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging./
Author:
Mariappan, Leo.
Description:
1 online resource (150 pages)
Notes:
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
Contained By:
Dissertations Abstracts International76-05B.
Subject:
Biomedical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3643645click for full text (PQDT)
ISBN:
9781321314175
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
Mariappan, Leo.
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
- 1 online resource (150 pages)
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
Thesis (Ph.D.)--University of Minnesota, 2014.
Includes bibliographical references
Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9781321314175Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Electrical impedanceIndex Terms--Genre/Form:
542853
Electronic books.
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
LDR
:04005nmm a2200397K 4500
001
2360593
005
20230928115721.5
006
m o d
007
cr mn ---uuuuu
008
241011s2014 xx obm 000 0 eng d
020
$a
9781321314175
035
$a
(MiAaPQ)AAI3643645
035
$a
(MiAaPQ)umn:15340
035
$a
AAI3643645
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Mariappan, Leo.
$3
3701215
245
1 0
$a
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging.
264
0
$c
2014
300
$a
1 online resource (150 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 76-05, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: He, Bin.
502
$a
Thesis (Ph.D.)--University of Minnesota, 2014.
504
$a
Includes bibliographical references
520
$a
Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Acoustics.
$3
879105
653
$a
Electrical impedance
653
$a
Magneto acoustic
653
$a
Ultrasound tomography
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0541
690
$a
0574
690
$a
0986
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Minnesota.
$b
Biomedical Engineering.
$3
1669049
773
0
$t
Dissertations Abstracts International
$g
76-05B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3643645
$z
click for full text (PQDT)
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9482949
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login