語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources./
作者:
Johnston, Daniel.
面頁冊數:
1 online resource (142 pages)
附註:
Source: Dissertations Abstracts International, Volume: 73-05, Section: B.
Contained By:
Dissertations Abstracts International73-05B.
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3475804click for full text (PQDT)
ISBN:
9781124899459
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources.
Johnston, Daniel.
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources.
- 1 online resource (142 pages)
Source: Dissertations Abstracts International, Volume: 73-05, Section: B.
Thesis (Ph.D.)--University of Idaho, 2011.
Includes bibliographical references
As a result of more outage-sensitive loads being integrated onto electrical power grids, standards for measuring the impacts of outages have been developed and implemented throughout the electric utility industry. Reliability standards include the System Average Interruption Duration Index (SAIDI), the System Average Interruption Frequency Index (SAIFI), the Customer Average Interruption Duration Index (CAIDI), and the Average Service Unavailability Index (ASUI). Intermittent green energy supplies, such as wind generation, connecting on those same electrical power grids have increased the possibility of negatively impacting system reliability. This research avoids the negative reliability affects of integrating variable wind generation onto the electrical system by considering an interconnection that (1) converts wind electrical power to stored hydrogen and (2) generates electrical power at load centers by using the stored hydrogen. A hydrogen distribution model, using a topology similar to the topology currently used for designing electrical distribution systems, was developed and evaluated using SAIDI, SAIFI, CAIDI, and ASUI while also considering the probability of lateral equipment failure. The results of the reliability analysis of the hydrogen model were then compared to the results of the reliability analysis of a typical electrical distribution system, showing significant savings for the hydrogen system. However, as equipment failures were introduced to both the hydrogen and typical electrical distribution system models, the hydrogen distribution system exhibited the greater performance degradation. The results of the model analysis showed that operationally the hydrogen distribution system will be a viable alternative to an electrical distribution system. The more emphasis on hydrogen component development would further reduce component degradations, frequency of customer interruptions, and outage durations.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9781124899459Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Electrical distributionIndex Terms--Genre/Form:
542853
Electronic books.
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources.
LDR
:03499nmm a2200421K 4500
001
2358969
005
20230830051534.5
006
m o d
007
cr mn ---uuuuu
008
241011s2011 xx obm 000 0 eng d
020
$a
9781124899459
035
$a
(MiAaPQ)AAI3475804
035
$a
AAI3475804
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Johnston, Daniel.
$3
3699517
245
1 0
$a
Comparative reliability assessment of a hydrogen distribution system and an electrical distribution system with variable power generation sources.
264
0
$c
2011
300
$a
1 online resource (142 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 73-05, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Johnson, Brian.
502
$a
Thesis (Ph.D.)--University of Idaho, 2011.
504
$a
Includes bibliographical references
520
$a
As a result of more outage-sensitive loads being integrated onto electrical power grids, standards for measuring the impacts of outages have been developed and implemented throughout the electric utility industry. Reliability standards include the System Average Interruption Duration Index (SAIDI), the System Average Interruption Frequency Index (SAIFI), the Customer Average Interruption Duration Index (CAIDI), and the Average Service Unavailability Index (ASUI). Intermittent green energy supplies, such as wind generation, connecting on those same electrical power grids have increased the possibility of negatively impacting system reliability. This research avoids the negative reliability affects of integrating variable wind generation onto the electrical system by considering an interconnection that (1) converts wind electrical power to stored hydrogen and (2) generates electrical power at load centers by using the stored hydrogen. A hydrogen distribution model, using a topology similar to the topology currently used for designing electrical distribution systems, was developed and evaluated using SAIDI, SAIFI, CAIDI, and ASUI while also considering the probability of lateral equipment failure. The results of the reliability analysis of the hydrogen model were then compared to the results of the reliability analysis of a typical electrical distribution system, showing significant savings for the hydrogen system. However, as equipment failures were introduced to both the hydrogen and typical electrical distribution system models, the hydrogen distribution system exhibited the greater performance degradation. The results of the model analysis showed that operationally the hydrogen distribution system will be a viable alternative to an electrical distribution system. The more emphasis on hydrogen component development would further reduce component degradations, frequency of customer interruptions, and outage durations.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Applied mathematics.
$3
2122814
650
4
$a
Alternative energy.
$3
3436775
653
$a
Electrical distribution
653
$a
Hydrogen distribution
653
$a
Power generation sources
653
$a
Reliability assessment
653
$a
Renewable power
653
$a
Wind generation
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0363
690
$a
0364
690
$a
0544
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Idaho.
$3
718915
773
0
$t
Dissertations Abstracts International
$g
73-05B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3475804
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9481325
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入