Interfacial Properties of Ocular Surface.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Interfacial Properties of Ocular Surface./
作者:
Liu, Chunzi.
面頁冊數:
1 online resource (157 pages)
附註:
Source: Dissertations Abstracts International, Volume: 84-05, Section: B.
Contained By:
Dissertations Abstracts International84-05B.
標題:
Physiology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29756128click for full text (PQDT)
ISBN:
9798357508317
Interfacial Properties of Ocular Surface.
Liu, Chunzi.
Interfacial Properties of Ocular Surface.
- 1 online resource (157 pages)
Source: Dissertations Abstracts International, Volume: 84-05, Section: B.
Thesis (Ph.D.)--Stanford University, 2022.
Includes bibliographical references
The ocular surface consists of corneal and conjunctival epithelia covered by a thin, aqueous tear film. A lubricious ocular surface can provide an active barrier against environmental threats. Mechanically, the mismatch between the length scales of corneo-conjunctival epithelium and tear film poses challenges for sustainable lubrication at the ocular surface and dynamic tear film homeostasis. Clinically, lubrication dysfunction plays a significant role in the pathogenesis of many ocular surface diseases, including dry eye disease, which remains the most common reason for ophthalmology visits. However, current treatments and new therapeutic approaches for ocular surface diseases are limited by a lack of fundamental understanding of the lubrication mechanism at the ocular surface and its relation to the pathology of lubrication dysfunction-associated diseases. Despite research efforts since the 1960s, it remains unclear whether boundary lubrication, mediated by epithelial surface molecules (glycoproteins, polysaccharides, and lipids), and hydrodynamic lubrication, mediated by the aqueous tear film, are sufficient to yield a live cell surface with ultra-low friction. This thesis focuses on designing new measurement techniques to investigate the interfacial, adhesive, and tribological properties of live ocular epithelial surfaces and their relations to dry eye disease (DED).Two essential cornerstones for a lubricious ocular surface are a sustainable hydration mechanism and a molecular-morphological design that protects the surface from wear and degradation. A historical and current view of the fundamental lubrication mechanism is presented in Chapter 1. To investigate how the ocular surface sustains constant hydration, the surface tensions of corneal and conjunctival epithelial layers are quantified in Chapter 2. The results showed that the ocular surface exhibits a surface tension gradient stabilized by amphiphilic molecules which ensures constant hydration. Contact angle hysteresis measurements showed that in addition to hydrophilicity, the ocular surface exhibits a high retentive force against fluid films, suggesting a protective mechanism against shear stress-induced tear film dewetting. Contrary to the previous hypothesis, we found that the contact angle hysteresis of corneal epithelium was dominated by its surface morphology rather than its mucin expression. Surprisingly, the high surface tension at the cell-air interface can induce delamination of a stratified corneal epithelial cell layer. Bulk moduli of cell layers were extracted by analyzing stresses at the triple line via Neumann's construction, which showed nonlinearity at high strain values. EDTA treatment showed that the cortical tension of the cytoskeletal components, instead of the adhesive forces at the cell adherens junctions, was the predominant contributor to the viscoelasticity of the epithelial sheets, consistent with previous reports. In addition, a simple model was constructed to demonstrate that a balance among cortical tension, focal adhesion, and cell surface tension is necessary to maintain a mechanically stable ocular surface.To investigate how altered molecular composition of the ocular surface induces DED-related symptoms, Chapter 3 and 4 presents a mucin-deficient cell model, and its shear adhesive properties were investigated with a novel live-cell rheometer. In a subset of dry eye patients, alterations in mucin expression and abnormal glycosylation patterns were found in patients' tear samples. A lack or a reduced amount of mucin molecules on the ocular surface can lead to increased frictional damage. To determine the adhesive and properties of live cell surfaces, we customized a live cell rheometer and performed stress relaxation experiments on a novel in vitro dry eye model that mimics the mucin-deficient dry eye ocular environment. Results showed that mucin-deficient corneal epithelial surfaces exhibited increased adhesive strengths against conjunctival epithelial surfaces. Furthermore, the addition of mucin-like recombinant lubricin molecules rescued the lubrication functions of the ocular surface in a dose-dependent fashion. The results suggested that membrane-bound glycoproteins are sufficient to modify the adhesive properties of ocular surfaces. A simple model was proposed to explain the observed trend in the frictional and adhesive response of live cell surfaces in the presence of additional protein molecules.Overall, this thesis illustrated a framework to measure the interfacial, adhesive, and tribological properties of ocular epithelium that can be adapted to a wide range of epithelial tissues to investigate bio-lubrication and tissue interfacial phenomena.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798357508317Subjects--Topical Terms:
518431
Physiology.
Index Terms--Genre/Form:
542853
Electronic books.
Interfacial Properties of Ocular Surface.
LDR
:06177nmm a2200457K 4500
001
2354661
005
20230428105642.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798357508317
035
$a
(MiAaPQ)AAI29756128
035
$a
(MiAaPQ)STANFORDxg637ks6075
035
$a
AAI29756128
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Liu, Chunzi.
$3
3695020
245
1 0
$a
Interfacial Properties of Ocular Surface.
264
0
$c
2022
300
$a
1 online resource (157 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 84-05, Section: B.
500
$a
Advisor: Dunn, Alexander Robert; Zia, Roseanna; Fuller, Gerald.
502
$a
Thesis (Ph.D.)--Stanford University, 2022.
504
$a
Includes bibliographical references
520
$a
The ocular surface consists of corneal and conjunctival epithelia covered by a thin, aqueous tear film. A lubricious ocular surface can provide an active barrier against environmental threats. Mechanically, the mismatch between the length scales of corneo-conjunctival epithelium and tear film poses challenges for sustainable lubrication at the ocular surface and dynamic tear film homeostasis. Clinically, lubrication dysfunction plays a significant role in the pathogenesis of many ocular surface diseases, including dry eye disease, which remains the most common reason for ophthalmology visits. However, current treatments and new therapeutic approaches for ocular surface diseases are limited by a lack of fundamental understanding of the lubrication mechanism at the ocular surface and its relation to the pathology of lubrication dysfunction-associated diseases. Despite research efforts since the 1960s, it remains unclear whether boundary lubrication, mediated by epithelial surface molecules (glycoproteins, polysaccharides, and lipids), and hydrodynamic lubrication, mediated by the aqueous tear film, are sufficient to yield a live cell surface with ultra-low friction. This thesis focuses on designing new measurement techniques to investigate the interfacial, adhesive, and tribological properties of live ocular epithelial surfaces and their relations to dry eye disease (DED).Two essential cornerstones for a lubricious ocular surface are a sustainable hydration mechanism and a molecular-morphological design that protects the surface from wear and degradation. A historical and current view of the fundamental lubrication mechanism is presented in Chapter 1. To investigate how the ocular surface sustains constant hydration, the surface tensions of corneal and conjunctival epithelial layers are quantified in Chapter 2. The results showed that the ocular surface exhibits a surface tension gradient stabilized by amphiphilic molecules which ensures constant hydration. Contact angle hysteresis measurements showed that in addition to hydrophilicity, the ocular surface exhibits a high retentive force against fluid films, suggesting a protective mechanism against shear stress-induced tear film dewetting. Contrary to the previous hypothesis, we found that the contact angle hysteresis of corneal epithelium was dominated by its surface morphology rather than its mucin expression. Surprisingly, the high surface tension at the cell-air interface can induce delamination of a stratified corneal epithelial cell layer. Bulk moduli of cell layers were extracted by analyzing stresses at the triple line via Neumann's construction, which showed nonlinearity at high strain values. EDTA treatment showed that the cortical tension of the cytoskeletal components, instead of the adhesive forces at the cell adherens junctions, was the predominant contributor to the viscoelasticity of the epithelial sheets, consistent with previous reports. In addition, a simple model was constructed to demonstrate that a balance among cortical tension, focal adhesion, and cell surface tension is necessary to maintain a mechanically stable ocular surface.To investigate how altered molecular composition of the ocular surface induces DED-related symptoms, Chapter 3 and 4 presents a mucin-deficient cell model, and its shear adhesive properties were investigated with a novel live-cell rheometer. In a subset of dry eye patients, alterations in mucin expression and abnormal glycosylation patterns were found in patients' tear samples. A lack or a reduced amount of mucin molecules on the ocular surface can lead to increased frictional damage. To determine the adhesive and properties of live cell surfaces, we customized a live cell rheometer and performed stress relaxation experiments on a novel in vitro dry eye model that mimics the mucin-deficient dry eye ocular environment. Results showed that mucin-deficient corneal epithelial surfaces exhibited increased adhesive strengths against conjunctival epithelial surfaces. Furthermore, the addition of mucin-like recombinant lubricin molecules rescued the lubrication functions of the ocular surface in a dose-dependent fashion. The results suggested that membrane-bound glycoproteins are sufficient to modify the adhesive properties of ocular surfaces. A simple model was proposed to explain the observed trend in the frictional and adhesive response of live cell surfaces in the presence of additional protein molecules.Overall, this thesis illustrated a framework to measure the interfacial, adhesive, and tribological properties of ocular epithelium that can be adapted to a wide range of epithelial tissues to investigate bio-lubrication and tissue interfacial phenomena.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Physiology.
$3
518431
650
4
$a
Glycoproteins.
$3
667972
650
4
$a
Flow velocity.
$3
3564851
650
4
$a
Cornea.
$3
1092873
650
4
$a
Adsorption.
$3
580046
650
4
$a
Energy.
$3
876794
650
4
$a
Pathology.
$3
643180
650
4
$a
Lipids.
$3
558980
650
4
$a
Contact angle.
$3
3320098
650
4
$a
Boundary conditions.
$3
3560411
650
4
$a
Thin films.
$3
626403
650
4
$a
Cell culture.
$3
604671
650
4
$a
COVID-19.
$3
3554449
650
4
$a
Aqueous solutions.
$3
3681511
650
4
$a
Viscosity.
$3
1050706
650
4
$a
Pandemics.
$3
3464080
650
4
$a
Microscopy.
$3
540544
650
4
$a
Lubricants & lubrication.
$3
3559685
650
4
$a
Eye diseases.
$3
3695021
650
4
$a
Role models.
$3
3301554
650
4
$a
Viscoelasticity.
$3
718183
650
4
$a
Hydrogels.
$3
1305894
650
4
$a
Interfaces.
$2
gtt
$3
834756
650
4
$a
Biology.
$3
522710
650
4
$a
Cellular biology.
$3
3172791
650
4
$a
Condensed matter physics.
$3
3173567
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Materials science.
$3
543314
650
4
$a
Mathematics.
$3
515831
650
4
$a
Mechanics.
$3
525881
650
4
$a
Ophthalmology.
$3
862704
650
4
$a
Physics.
$3
516296
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0571
690
$a
0791
690
$a
0719
690
$a
0306
690
$a
0379
690
$a
0611
690
$a
0204
690
$a
0794
690
$a
0405
690
$a
0346
690
$a
0381
690
$a
0605
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Stanford University.
$3
754827
773
0
$t
Dissertations Abstracts International
$g
84-05B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29756128
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9477017
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入