語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters./
作者:
Ali, Muhammad.
面頁冊數:
1 online resource (168 pages)
附註:
Source: Masters Abstracts International, Volume: 83-11.
Contained By:
Masters Abstracts International83-11.
標題:
Propagation. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29239045click for full text (PQDT)
ISBN:
9798438766100
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters.
Ali, Muhammad.
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters.
- 1 online resource (168 pages)
Source: Masters Abstracts International, Volume: 83-11.
Thesis (M.Eng.Sc.)--The University of Western Ontario (Canada), 2022.
Includes bibliographical references
The clamp-on ultrasonic flowmeter measures the fluid flow velocity and flowrate with the help of ultrasonic waves. Flow profile distortion due to pipe network disturbances cause uncertainty in the flowrate measurement. A numerical and experimental investigation is conducted to model the performance of a clamp-on ultrasonic flowmeter onto a straight pipe and at x/d=1 downstream of a 90° elbow for the flowrate range of 0.3-2.5m3/hr. The average percentage error in the flowrate at x/d=1 downstream of the elbow estimated from the numerical and experimental study is 8.6% and 10.8% respectively. The correction factors suggested for the numerical and experimental data reduces the average percentage error to 0.7% and 2.3% respectively. The repeatability tests show ±1.8% uncertainty in the flowrate. Integrating velocity along the acoustic path can roughly estimate measurement uncertainty due to flow profile without simulating the ultrasonic wave propagation numerically. This research will help increase the use of clamp-on ultrasonic flowmeters in practical applications with reduced uncertainty.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798438766100Subjects--Topical Terms:
3680519
Propagation.
Index Terms--Genre/Form:
542853
Electronic books.
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters.
LDR
:02332nmm a2200349K 4500
001
2354455
005
20230414084802.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798438766100
035
$a
(MiAaPQ)AAI29239045
035
$a
(MiAaPQ)oaiirlibuwocaetd10971
035
$a
AAI29239045
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Ali, Muhammad.
$3
3432704
245
1 0
$a
Evaluation of Clamp-On Ultrasonic Liquid Flowmeters.
264
0
$c
2022
300
$a
1 online resource (168 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 83-11.
500
$a
Advisor: Savory, Eric.
502
$a
Thesis (M.Eng.Sc.)--The University of Western Ontario (Canada), 2022.
504
$a
Includes bibliographical references
520
$a
The clamp-on ultrasonic flowmeter measures the fluid flow velocity and flowrate with the help of ultrasonic waves. Flow profile distortion due to pipe network disturbances cause uncertainty in the flowrate measurement. A numerical and experimental investigation is conducted to model the performance of a clamp-on ultrasonic flowmeter onto a straight pipe and at x/d=1 downstream of a 90° elbow for the flowrate range of 0.3-2.5m3/hr. The average percentage error in the flowrate at x/d=1 downstream of the elbow estimated from the numerical and experimental study is 8.6% and 10.8% respectively. The correction factors suggested for the numerical and experimental data reduces the average percentage error to 0.7% and 2.3% respectively. The repeatability tests show ±1.8% uncertainty in the flowrate. Integrating velocity along the acoustic path can roughly estimate measurement uncertainty due to flow profile without simulating the ultrasonic wave propagation numerically. This research will help increase the use of clamp-on ultrasonic flowmeters in practical applications with reduced uncertainty.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Propagation.
$3
3680519
650
4
$a
Viscosity.
$3
1050706
650
4
$a
Vortices.
$3
3681507
650
4
$a
Turbulence models.
$3
3682363
650
4
$a
Flow velocity.
$3
3564851
650
4
$a
Acoustics.
$3
879105
650
4
$a
Reynolds number.
$3
3681436
650
4
$a
Flow control.
$3
3681437
650
4
$a
Shear stress.
$3
3681838
650
4
$a
Ultrasonic technology.
$3
3694807
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Mechanical engineering.
$3
649730
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0986
690
$a
0548
690
$a
0204
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
The University of Western Ontario (Canada).
$3
1017622
773
0
$t
Masters Abstracts International
$g
83-11.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29239045
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9476811
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入