語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia./
作者:
Aram, Morteza Ghaderi.
面頁冊數:
1 online resource (105 pages)
附註:
Source: Dissertations Abstracts International, Volume: 83-11, Section: B.
Contained By:
Dissertations Abstracts International83-11B.
標題:
Receivers & amplifiers. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29101150click for full text (PQDT)
ISBN:
9798426886049
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia.
Aram, Morteza Ghaderi.
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia.
- 1 online resource (105 pages)
Source: Dissertations Abstracts International, Volume: 83-11, Section: B.
Thesis (Licentiate)--Chalmers Tekniska Hogskola (Sweden), 2022.
Includes bibliographical references
The death toll of cancers is on the rise worldwide and surviving patients suffer significant side effects from conventional therapies. To reduce the level of toxicity in patients treated with the conventional treatment modalities, hyperthermia (HT) has been investigated as an adjuvant modality and shown to be a potent tumor cell sensitizer for radio- and chemotherapy. During the past couple of decades, several clinical radiofrequency HT systems, aka applicators, have been developed to heat tumors. Systems based on radiative applicators are the most widely used within the hyperthermic community. They consist of a conformal antenna array and need a beamforming method in order to focus EM energy on the tumor through constructive interference while sparing the healthy tissue from excessive heating. Therefore, a hyperthermia treatment planning (HTP) stage is required before each patient's first treatment session to optimize and control the EM power deposition as well as the resultant temperature distribution.Despite the vast amount of effort invested in HTP and the progress made in this regard during recent years, the clinical exploitation of HT is still hampered by technical limitations and patients can still experience discomfort during clinical trials. This, therefore, calls for a more efficient hardware design, better control of EM power deposition to minimize unwanted hotspots, and more accurate quantification and monitoring of the treatment outcome. Given these demands, the present report tries to address some of the above-mentioned challenges by proposing• A new antenna model customized for HT applications which surpasses previously proposed models from several points of view.• A hybrid beamforming method for faster convergence and a versatile, robust thermal solver for handling sophisticated scenarios.• A radiobiological model to quantify the outcome of a combined treatment modality of the Gamma Knife radiosurgery and HT.• A differential image reconstruction method to assess the feasibility of using the same system for both heating and microwave thermometry.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798426886049Subjects--Topical Terms:
3559205
Receivers & amplifiers.
Index Terms--Genre/Form:
542853
Electronic books.
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia.
LDR
:03502nmm a2200421K 4500
001
2354244
005
20230403071157.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798426886049
035
$a
(MiAaPQ)AAI29101150
035
$a
(MiAaPQ)Chalmers_SE528711
035
$a
AAI29101150
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Aram, Morteza Ghaderi.
$3
3694592
245
1 0
$a
Antenna Design, Radiobiological Modelling, and Non-Invasive Monitoring for Microwave Hyperthermia.
264
0
$c
2022
300
$a
1 online resource (105 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 83-11, Section: B.
502
$a
Thesis (Licentiate)--Chalmers Tekniska Hogskola (Sweden), 2022.
504
$a
Includes bibliographical references
520
$a
The death toll of cancers is on the rise worldwide and surviving patients suffer significant side effects from conventional therapies. To reduce the level of toxicity in patients treated with the conventional treatment modalities, hyperthermia (HT) has been investigated as an adjuvant modality and shown to be a potent tumor cell sensitizer for radio- and chemotherapy. During the past couple of decades, several clinical radiofrequency HT systems, aka applicators, have been developed to heat tumors. Systems based on radiative applicators are the most widely used within the hyperthermic community. They consist of a conformal antenna array and need a beamforming method in order to focus EM energy on the tumor through constructive interference while sparing the healthy tissue from excessive heating. Therefore, a hyperthermia treatment planning (HTP) stage is required before each patient's first treatment session to optimize and control the EM power deposition as well as the resultant temperature distribution.Despite the vast amount of effort invested in HTP and the progress made in this regard during recent years, the clinical exploitation of HT is still hampered by technical limitations and patients can still experience discomfort during clinical trials. This, therefore, calls for a more efficient hardware design, better control of EM power deposition to minimize unwanted hotspots, and more accurate quantification and monitoring of the treatment outcome. Given these demands, the present report tries to address some of the above-mentioned challenges by proposing• A new antenna model customized for HT applications which surpasses previously proposed models from several points of view.• A hybrid beamforming method for faster convergence and a versatile, robust thermal solver for handling sophisticated scenarios.• A radiobiological model to quantify the outcome of a combined treatment modality of the Gamma Knife radiosurgery and HT.• A differential image reconstruction method to assess the feasibility of using the same system for both heating and microwave thermometry.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Receivers & amplifiers.
$3
3559205
650
4
$a
Dielectric properties.
$3
3560265
650
4
$a
Metastasis.
$3
818532
650
4
$a
Brain cancer.
$3
3557728
650
4
$a
Mortality.
$3
533218
650
4
$a
Cancer therapies.
$3
3557730
650
4
$a
Hypoxia.
$3
3561738
650
4
$a
Head & neck cancer.
$3
3694593
650
4
$a
Heat.
$3
573595
650
4
$a
Skin.
$3
843661
650
4
$a
Fever.
$3
3444643
650
4
$a
Energy.
$3
876794
650
4
$a
Breast cancer.
$3
3543523
650
4
$a
Drug dosages.
$3
3557732
650
4
$a
Patients.
$3
1961957
650
4
$a
Surgery.
$3
707153
650
4
$a
Electric fields.
$3
880423
650
4
$a
Antennas.
$3
3681648
650
4
$a
Design.
$3
518875
650
4
$a
Melanoma.
$3
1359627
650
4
$a
Tumors.
$3
893964
650
4
$a
Radiation therapy.
$3
3557731
650
4
$a
Chemotherapy.
$3
728559
650
4
$a
Hyperthermia.
$3
3685312
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Engineering.
$3
586835
650
4
$a
Medicine.
$3
641104
650
4
$a
Nuclear physics.
$3
517741
650
4
$a
Oncology.
$3
751006
650
4
$a
Physics.
$3
516296
650
4
$a
Therapy.
$3
3343697
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0791
690
$a
0389
690
$a
0576
690
$a
0544
690
$a
0537
690
$a
0564
690
$a
0756
690
$a
0992
690
$a
0605
690
$a
0212
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Chalmers Tekniska Hogskola (Sweden).
$3
1913472
773
0
$t
Dissertations Abstracts International
$g
83-11B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29101150
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9476600
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入