語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices./
作者:
Eickhoff, Steffen.
面頁冊數:
1 online resource (189 pages)
附註:
Source: Dissertations Abstracts International, Volume: 83-02, Section: B.
Contained By:
Dissertations Abstracts International83-02B.
標題:
Communication. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28760872click for full text (PQDT)
ISBN:
9798535579146
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices.
Eickhoff, Steffen.
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices.
- 1 online resource (189 pages)
Source: Dissertations Abstracts International, Volume: 83-02, Section: B.
Thesis (Ph.D.)--Liverpool John Moores University (United Kingdom), 2021.
Includes bibliographical references
Electrical stimulation (ES) is a neuromodulation technique that uses electrical pulses to modulate the activity of excitable cells to provide a therapeutic effect. Many past and present ES applications use rectangular current waveforms that have been well studied and are easy to generate. However, an extensive body of scientific literature describes different stimulation waveforms and their potential benefits. A key measure of stimulation performance is the amplitude required to reach a certain percentual threshold of activation, as it directly influences important ES parameters such as energy consumption per pulse and charge density. The research summarized in this thesis was conducted to re-examine some of the most-commonly suggested ES waveform variations in a rodent in-vivo nerve-muscle preparation. A key feature of our experimental model is the ability to test stimulation with both principal electrode configurations, monopolar and bipolar, under computer control and in randomized order. Among the rectangular stimulation waveforms, we investigated the effect of interphase gaps (IPGs), asymmetric charge balanced pulses, and subthreshold conditioning pre-pulses. For all these rectangular waveforms, we surprisingly observed opposite effects in the monopolar compared to the bipolar stimulation electrode configuration. The rationale for this consistent observation was identified by analyzing electroneurograms (ENGs) of the stimulated nerve. In the monopolar configuration, biphasic pulses first evoked compound action potentials (eCAPs) as a response to the first field transition. In the bipolar electrode configuration, that is the mode in which many contemporary ES devices, including the envisioned miniaturized electroceuticals, operate, eCAPs were first elicited at the return electrode in response to the middle field transition of biphasic pulses. As all rectangular waveform variations achieve their effect by modulating the amplitude and timing of cathodic (excitatory) and anodic (inhibitory) field transitions, the inverted current profile at the bipolar return electrode explains these observed opposite effects.Further we investigated the claimed benefits of non-rectangular, Gaussian stimulation waveforms in our animal model. In our study only moderate energy savings of up to 17% were observed, a finding that is surprising in light of the predicted range of benefits of up to 60% energy savings with this novel waveform in question. Additionally, we identified a major disadvantage in terms of substantially increased maximum instantaneous power requirements with Gaussian compared to rectangular stimuli.We examined physiological changes in fast twitch muscle following motor nerve injury, and optimal stimulation strategies for activation of denervated muscle. While a high frequency doublet has previously been identified to enhance stimulation efficiency of healthy fast twitch muscle, an effect that has been termed "doublet effect", we here show that this benefit is gradually lost in muscle during denervation. Lastly, the effect of long duration stimulation pulses, that are required to activate denervated muscle, on nerve is examined. We show that these long pulses can activate nerves up to three times when the three field transition within the biphasic pulses are separated by more than (i.e., when the phase width is above) the refractory period of that nerve. This observation challenges state-of-the-art computational models of extracellular nerve stimulation that do not seem to predict such multiple activations. Further, an undesired up to threefold co-activation of innervated structures nearby the denervated stimulation target warrants further research to study whether these co-activations can be lessened with alternative stimulation waveforms such as ramped sawtooth pulses.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798535579146Subjects--Topical Terms:
524709
Communication.
Subjects--Index Terms:
Electrical StimulationIndex Terms--Genre/Form:
542853
Electronic books.
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices.
LDR
:05385nmm a2200445K 4500
001
2353406
005
20230306113823.5
006
m o d
007
cr mn ---uuuuu
008
241011s2021 xx obm 000 0 eng d
020
$a
9798535579146
035
$a
(MiAaPQ)AAI28760872
035
$a
(MiAaPQ)LiverpoolJohnMoores14298
035
$a
AAI28760872
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Eickhoff, Steffen.
$3
3693752
245
1 0
$a
Optimal Strategies for Electrical Stimulation with Implantable Neuromodulation Devices.
264
0
$c
2021
300
$a
1 online resource (189 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 83-02, Section: B.
500
$a
Advisor: Jarvis, Jonathan; Barton, Gabor.
502
$a
Thesis (Ph.D.)--Liverpool John Moores University (United Kingdom), 2021.
504
$a
Includes bibliographical references
520
$a
Electrical stimulation (ES) is a neuromodulation technique that uses electrical pulses to modulate the activity of excitable cells to provide a therapeutic effect. Many past and present ES applications use rectangular current waveforms that have been well studied and are easy to generate. However, an extensive body of scientific literature describes different stimulation waveforms and their potential benefits. A key measure of stimulation performance is the amplitude required to reach a certain percentual threshold of activation, as it directly influences important ES parameters such as energy consumption per pulse and charge density. The research summarized in this thesis was conducted to re-examine some of the most-commonly suggested ES waveform variations in a rodent in-vivo nerve-muscle preparation. A key feature of our experimental model is the ability to test stimulation with both principal electrode configurations, monopolar and bipolar, under computer control and in randomized order. Among the rectangular stimulation waveforms, we investigated the effect of interphase gaps (IPGs), asymmetric charge balanced pulses, and subthreshold conditioning pre-pulses. For all these rectangular waveforms, we surprisingly observed opposite effects in the monopolar compared to the bipolar stimulation electrode configuration. The rationale for this consistent observation was identified by analyzing electroneurograms (ENGs) of the stimulated nerve. In the monopolar configuration, biphasic pulses first evoked compound action potentials (eCAPs) as a response to the first field transition. In the bipolar electrode configuration, that is the mode in which many contemporary ES devices, including the envisioned miniaturized electroceuticals, operate, eCAPs were first elicited at the return electrode in response to the middle field transition of biphasic pulses. As all rectangular waveform variations achieve their effect by modulating the amplitude and timing of cathodic (excitatory) and anodic (inhibitory) field transitions, the inverted current profile at the bipolar return electrode explains these observed opposite effects.Further we investigated the claimed benefits of non-rectangular, Gaussian stimulation waveforms in our animal model. In our study only moderate energy savings of up to 17% were observed, a finding that is surprising in light of the predicted range of benefits of up to 60% energy savings with this novel waveform in question. Additionally, we identified a major disadvantage in terms of substantially increased maximum instantaneous power requirements with Gaussian compared to rectangular stimuli.We examined physiological changes in fast twitch muscle following motor nerve injury, and optimal stimulation strategies for activation of denervated muscle. While a high frequency doublet has previously been identified to enhance stimulation efficiency of healthy fast twitch muscle, an effect that has been termed "doublet effect", we here show that this benefit is gradually lost in muscle during denervation. Lastly, the effect of long duration stimulation pulses, that are required to activate denervated muscle, on nerve is examined. We show that these long pulses can activate nerves up to three times when the three field transition within the biphasic pulses are separated by more than (i.e., when the phase width is above) the refractory period of that nerve. This observation challenges state-of-the-art computational models of extracellular nerve stimulation that do not seem to predict such multiple activations. Further, an undesired up to threefold co-activation of innervated structures nearby the denervated stimulation target warrants further research to study whether these co-activations can be lessened with alternative stimulation waveforms such as ramped sawtooth pulses.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Communication.
$3
524709
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Neurosciences.
$3
588700
650
4
$a
Medicine.
$3
641104
650
4
$a
Surgery.
$3
707153
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Hormones.
$3
548778
650
4
$a
Electrodes.
$3
629151
650
4
$a
Equilibrium.
$3
668417
650
4
$a
Codes.
$3
3560019
650
4
$a
Energy.
$3
876794
650
4
$a
Potassium.
$3
3562093
650
4
$a
Organisms.
$3
627067
650
4
$a
20th century.
$3
1972782
650
4
$a
Cell culture.
$3
604671
650
4
$a
Efficiency.
$3
753744
650
4
$a
Proteins.
$3
558769
650
4
$a
Propagation.
$3
3680519
650
4
$a
Velocity.
$3
3560495
650
4
$a
Neurons.
$3
588699
650
4
$a
Adenosine triphosphatase.
$3
2180834
650
4
$a
Hypotheses.
$3
3560118
650
4
$a
Musculoskeletal system.
$3
548825
650
4
$a
Experiments.
$3
525909
650
4
$a
Sodium.
$3
3562677
650
4
$a
Copyright.
$3
601694
650
4
$a
Medical equipment.
$3
3560831
650
4
$a
Nervous system.
$3
672432
650
4
$a
Nobel prizes.
$3
647941
650
4
$a
Variance analysis.
$3
3544969
653
$a
Electrical Stimulation
653
$a
Implantable devices
653
$a
Neuromodulation devices
653
$a
Electroceuticals
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0459
690
$a
0576
690
$a
0544
690
$a
0541
690
$a
0564
690
$a
0317
690
$a
0791
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Liverpool John Moores University (United Kingdom).
$3
3556313
773
0
$t
Dissertations Abstracts International
$g
83-02B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28760872
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9475762
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入