語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination./
作者:
Tan, Ying Rui.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
54 p.
附註:
Source: Masters Abstracts International, Volume: 82-12.
Contained By:
Masters Abstracts International82-12.
標題:
Dentistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28411613
ISBN:
9798515282349
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination.
Tan, Ying Rui.
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 54 p.
Source: Masters Abstracts International, Volume: 82-12.
Thesis (M.S.)--Temple University, 2021.
This item must not be sold to any third party vendors.
Introduction: The prevalence of implant treatment has increased tremendously over the past few decades. In the process of either treating peri-implantitis or during the implant maintenance phase, it has been noted that certain implant decontamination methods may generate particles from implant surfaces. This may result in potential for disease exacerbation and irreversible damage to the implant surface. Although the Er: YAG (erbium-doped yttrium aluminum garnet) laser has been considered to have the best properties for the decontamination of the implant surface, there is limited data on the amount of titanium and zirconia particles that can be generated and released in the process.Purpose: The aim of this in vitro study was to investigate the possible generation of titanium and zirconia particles when the Er:YAG laser is used as a tool for implant decontamination and to assess for any possible surface alterations that may have resulted from the use of the Er:YAG laser.Materials and Methods: Six (N=6) Ti-Zirconium alloy (Roxolid®; Straumann® USA) and six (N=6) yttra-stabilized tetragonal zirconia (PURE® Ceramic; Straumann® USA) machined material discs, as well as two (N=2) expired Ti sandblasted acid-treated implants (Ti SLA® Implant; Straumann USA) and two (N=2) expired acid-etched zirconium-dioxide ceramic implants (PURE® Ceramic ZLA® Implant; Straumann® USA) were irradiated with the Er:YAG laser (LiteTouchTM) using the gentle treatment mode for implant decontamination for 30 and 60 seconds. The coolant water generated during laser irradiation was collected and filtered through polycarbonate track etch (PCTE) hydrophilic membrane filters using a vacuum filtration assembly unit. The PCTE membranes were then analyzed for presence of titanium and zirconia particles using a Field Emission Gun Scanning Electron Microscope (FEG-SEM). The elemental composition of the particles was compared with that of the implants and discs using Energy-dispersive X-ray spectroscopy (EDS). The surfaces of the discs and implants were also inspected for morphological alterations. The average surface roughness (Ra, Ry, Rz) of the discs before and after laser application were measured using a 2-dimensional surface profilometer. A paired sample t-test was used for statistical analysis to compare the surface roughness values before and after laser application.Results: No titanium or zirconia particles were collected after laser irradiation of the material discs after laser irradiation. Titanium and zirconia particles were detected after laser irradiation on the implants. There were no surface topographical alterations evident at higher magnification for the titanium and zirconia material discs, and implants after laser irradiation. There was a statistically significant decrease in all surface roughness parameters measured (Ra, Ry, Rz) after 60 seconds of laser irradiation for the zirconia discs.Conclusions: Within the limitations of this study, the Er:YAG laser used in gentle treatment mode for implant decontamination resulted in no visible damages to the titanium and zirconia implant surfaces. There were some titanium and zirconia particles produced during the laser irradiation on implants but no produced over discs. Additional in-vitro and clinical studies will have to be conducted to assess the clinical significance of these particles.
ISBN: 9798515282349Subjects--Topical Terms:
828971
Dentistry.
Subjects--Index Terms:
Er:YAG
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination.
LDR
:04535nmm a2200397 4500
001
2352003
005
20221111120950.5
008
241004s2021 ||||||||||||||||| ||eng d
020
$a
9798515282349
035
$a
(MiAaPQ)AAI28411613
035
$a
AAI28411613
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Tan, Ying Rui.
$3
3691614
245
1 0
$a
Titanium and Zirconia Particle Release from Implant Surfaces During Er: Yag Laser Decontamination.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
54 p.
500
$a
Source: Masters Abstracts International, Volume: 82-12.
500
$a
Advisor: Dimaira, Michele J.
502
$a
Thesis (M.S.)--Temple University, 2021.
506
$a
This item must not be sold to any third party vendors.
520
$a
Introduction: The prevalence of implant treatment has increased tremendously over the past few decades. In the process of either treating peri-implantitis or during the implant maintenance phase, it has been noted that certain implant decontamination methods may generate particles from implant surfaces. This may result in potential for disease exacerbation and irreversible damage to the implant surface. Although the Er: YAG (erbium-doped yttrium aluminum garnet) laser has been considered to have the best properties for the decontamination of the implant surface, there is limited data on the amount of titanium and zirconia particles that can be generated and released in the process.Purpose: The aim of this in vitro study was to investigate the possible generation of titanium and zirconia particles when the Er:YAG laser is used as a tool for implant decontamination and to assess for any possible surface alterations that may have resulted from the use of the Er:YAG laser.Materials and Methods: Six (N=6) Ti-Zirconium alloy (Roxolid®; Straumann® USA) and six (N=6) yttra-stabilized tetragonal zirconia (PURE® Ceramic; Straumann® USA) machined material discs, as well as two (N=2) expired Ti sandblasted acid-treated implants (Ti SLA® Implant; Straumann USA) and two (N=2) expired acid-etched zirconium-dioxide ceramic implants (PURE® Ceramic ZLA® Implant; Straumann® USA) were irradiated with the Er:YAG laser (LiteTouchTM) using the gentle treatment mode for implant decontamination for 30 and 60 seconds. The coolant water generated during laser irradiation was collected and filtered through polycarbonate track etch (PCTE) hydrophilic membrane filters using a vacuum filtration assembly unit. The PCTE membranes were then analyzed for presence of titanium and zirconia particles using a Field Emission Gun Scanning Electron Microscope (FEG-SEM). The elemental composition of the particles was compared with that of the implants and discs using Energy-dispersive X-ray spectroscopy (EDS). The surfaces of the discs and implants were also inspected for morphological alterations. The average surface roughness (Ra, Ry, Rz) of the discs before and after laser application were measured using a 2-dimensional surface profilometer. A paired sample t-test was used for statistical analysis to compare the surface roughness values before and after laser application.Results: No titanium or zirconia particles were collected after laser irradiation of the material discs after laser irradiation. Titanium and zirconia particles were detected after laser irradiation on the implants. There were no surface topographical alterations evident at higher magnification for the titanium and zirconia material discs, and implants after laser irradiation. There was a statistically significant decrease in all surface roughness parameters measured (Ra, Ry, Rz) after 60 seconds of laser irradiation for the zirconia discs.Conclusions: Within the limitations of this study, the Er:YAG laser used in gentle treatment mode for implant decontamination resulted in no visible damages to the titanium and zirconia implant surfaces. There were some titanium and zirconia particles produced during the laser irradiation on implants but no produced over discs. Additional in-vitro and clinical studies will have to be conducted to assess the clinical significance of these particles.
590
$a
School code: 0225.
650
4
$a
Dentistry.
$3
828971
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Surgery.
$3
707153
650
4
$a
Molecular biology.
$3
517296
653
$a
Er:YAG
653
$a
Implant
653
$a
Laser
653
$a
Particle
653
$a
Titanium
653
$a
Zirconia
690
$a
0567
690
$a
0576
690
$a
0541
690
$a
0307
710
2
$a
Temple University.
$b
Oral Biology.
$3
3179289
773
0
$t
Masters Abstracts International
$g
82-12.
790
$a
0225
791
$a
M.S.
792
$a
2021
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28411613
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9474441
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入