Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait./
作者:
Washabaugh, Edward Peter, IV.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
280 p.
附註:
Source: Dissertations Abstracts International, Volume: 83-05, Section: B.
Contained By:
Dissertations Abstracts International83-05B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28845374
ISBN:
9798471102354
Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait.
Washabaugh, Edward Peter, IV.
Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 280 p.
Source: Dissertations Abstracts International, Volume: 83-05, Section: B.
Thesis (Ph.D.)--University of Michigan, 2021.
This item must not be sold to any third party vendors.
Injuries to the neuromusculoskeletal systems often result in muscle weakness, abnormal coordination strategies, and gait impairments. Functional resistance training during walking-where a patient walks while a device increases loading on the leg-is an emerging approach to combat these symptoms. While simple passive devices (i.e., ankle weights and resistance bands) can be applied for this training, rehabilitation robots have more potential upside because they can be controlled to treat multiple gait abnormalities and can be monitored by clinicians. However, the cost of conventional robotic devices limits their use in the clinical or home setting. Hence, in this dissertation, we designed, developed, and tested passive and semi-passive wearable exoskeleton devices as low-cost solutions for providing controllable/configurable functional resistance training during walking. We developed and tested two passive exoskeleton devices for providing resistance to walking and tested their effects on able-bodied participants and stroke survivors. First, we created a patented device that used a passive magnetic brake to provide a viscous (i.e., velocity-dependent) resistance to the knee. The resistive properties of the device could be placed under computer control (i.e., made semi-passive) to control resistance in real-time. Next, we created a passive exoskeleton that provided an elastic (i.e., position-dependent) resistance. While not controllable, this device was highly configurable. Meaning it could be used to provide resistance to joint flexion, extension, or to both (i.e., bidirectionally). Human subjects testing with these devices indicated they increased lower-extremity joint moments, powers, and muscle activation during training. Training also resulted in significant aftereffects-a potential indicator of therapeutic effectiveness-once the resistance was removed. A separate experiment indicated that individuals often kinematically slack (i.e., reduce joint excursions to minimize effort) when resistance is added to the limb. We also found that providing visual feedback of joint angles during training significantly increased muscle activation and kinematic aftereffects (i.e., reduced slacking). With passive devices, the type of passive element used largely dictates the muscle groups, types of muscle contraction, joint actions, and the phases of gait when a device is able to apply resistance. To examine this issue, we compared the training effects of viscous and elastic devices that provided bidirectional resistance to the knee during gait. Additionally, we compared training with viscous resistances at the hip and knee joints. While the resistance type and targeted joint altered moments, powers, and muscle activation patterns, these methods did not differ in their ability to produce aftereffects, alter neural excitability, or induce fatigue in the leg muscles. While this may indicate that the resistance type does not have a large effect on functional resistance training during walking, it is possible that an extended training with these devices could produce a different result. Lastly, we used musculoskeletal modeling in OpenSim to directly compare several strategies that have been used to provide functional resistance training to gait in the clinic or laboratory setting. We found that devices differed in their ability to alter gait parameters during walking. Hence, these findings could help clinicians when selecting a resistive strategy for their patients, or engineers when designing new devices or control schemes. Collectively, this dissertation introduces a new class of wearable devices for functional resistance training during walking and establishes the biomechanical and neurophysiological effects and the clinical potential of these devices in able-bodied and stroke survivors.
ISBN: 9798471102354Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Rehabilitation
Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait.
LDR
:05226nmm a2200409 4500
001
2351954
005
20221111113723.5
008
241004s2021 ||||||||||||||||| ||eng d
020
$a
9798471102354
035
$a
(MiAaPQ)AAI28845374
035
$a
(MiAaPQ)umichrackham003717
035
$a
AAI28845374
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Washabaugh, Edward Peter, IV.
$3
3691554
245
1 0
$a
Functional Resistance Training During Walking: Design, Testing, and Evaluation of Passive and Semi-Passive Wearable Devices for Providing Targeted Resistance to the Leg During Gait.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
280 p.
500
$a
Source: Dissertations Abstracts International, Volume: 83-05, Section: B.
500
$a
Advisor: Krishnan, Chandramouli.
502
$a
Thesis (Ph.D.)--University of Michigan, 2021.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Injuries to the neuromusculoskeletal systems often result in muscle weakness, abnormal coordination strategies, and gait impairments. Functional resistance training during walking-where a patient walks while a device increases loading on the leg-is an emerging approach to combat these symptoms. While simple passive devices (i.e., ankle weights and resistance bands) can be applied for this training, rehabilitation robots have more potential upside because they can be controlled to treat multiple gait abnormalities and can be monitored by clinicians. However, the cost of conventional robotic devices limits their use in the clinical or home setting. Hence, in this dissertation, we designed, developed, and tested passive and semi-passive wearable exoskeleton devices as low-cost solutions for providing controllable/configurable functional resistance training during walking. We developed and tested two passive exoskeleton devices for providing resistance to walking and tested their effects on able-bodied participants and stroke survivors. First, we created a patented device that used a passive magnetic brake to provide a viscous (i.e., velocity-dependent) resistance to the knee. The resistive properties of the device could be placed under computer control (i.e., made semi-passive) to control resistance in real-time. Next, we created a passive exoskeleton that provided an elastic (i.e., position-dependent) resistance. While not controllable, this device was highly configurable. Meaning it could be used to provide resistance to joint flexion, extension, or to both (i.e., bidirectionally). Human subjects testing with these devices indicated they increased lower-extremity joint moments, powers, and muscle activation during training. Training also resulted in significant aftereffects-a potential indicator of therapeutic effectiveness-once the resistance was removed. A separate experiment indicated that individuals often kinematically slack (i.e., reduce joint excursions to minimize effort) when resistance is added to the limb. We also found that providing visual feedback of joint angles during training significantly increased muscle activation and kinematic aftereffects (i.e., reduced slacking). With passive devices, the type of passive element used largely dictates the muscle groups, types of muscle contraction, joint actions, and the phases of gait when a device is able to apply resistance. To examine this issue, we compared the training effects of viscous and elastic devices that provided bidirectional resistance to the knee during gait. Additionally, we compared training with viscous resistances at the hip and knee joints. While the resistance type and targeted joint altered moments, powers, and muscle activation patterns, these methods did not differ in their ability to produce aftereffects, alter neural excitability, or induce fatigue in the leg muscles. While this may indicate that the resistance type does not have a large effect on functional resistance training during walking, it is possible that an extended training with these devices could produce a different result. Lastly, we used musculoskeletal modeling in OpenSim to directly compare several strategies that have been used to provide functional resistance training to gait in the clinic or laboratory setting. We found that devices differed in their ability to alter gait parameters during walking. Hence, these findings could help clinicians when selecting a resistive strategy for their patients, or engineers when designing new devices or control schemes. Collectively, this dissertation introduces a new class of wearable devices for functional resistance training during walking and establishes the biomechanical and neurophysiological effects and the clinical potential of these devices in able-bodied and stroke survivors.
590
$a
School code: 0127.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Physical therapy.
$3
588713
650
4
$a
Robotics.
$3
519753
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Kinesiology.
$3
517627
653
$a
Rehabilitation
653
$a
Gait
653
$a
Neuroplasticity
653
$a
Simulation
690
$a
0541
690
$a
0771
690
$a
0382
690
$a
0575
690
$a
0648
710
2
$a
University of Michigan.
$b
Biomedical Engineering.
$3
2096486
773
0
$t
Dissertations Abstracts International
$g
83-05B.
790
$a
0127
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28845374
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9474392
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入